The exact function of these connectors are assigned by the blades, please consult the specific blade
user’s guide to determine the ultimate function of the connector.
6.0
GETTING STARTED AND RUNNING THE Z3-MVE-R16
6.1
Basic Setup and Operation
(1)
Mount the MVE-R16 chassis onto a 19-inch standard rack
(2)
Plug and route the AC power cord to the AC power source
(3)
Insert and lock all desired function blades
(4)
Insert and lock as many blank panel covers as necessary to completely close the front of the
unit.
(5)
Connect the cables as required per each function blade
(6)
Turn power on
NOTE
: It is mandatory to have all slots of the chassis occupied, and the BLE264-FP blanks *
MUST
* be used
where there are no active blades. The entire front of the MVE-R16 must be enclosed.
7.0
IMPORTANT NOTES
7.2
Compatible Blades
Only insert into the MVE-R16 blades compatible with the MVE-R16 system. At the time of this writing
the compatible function blades are BLE264-H4 (4 channels of H264 encoding with HDMI input),
BLE264-S4 (4 channels of H264 encoding with SDI input) and the BLD265-SC2 (two channels of H264 or
H265 decoding with composite and SDI output).
Please consult Z3 Technology for additional functions.
7.3
Cooling
The MVE-R16 chassis contains four fans used to bring in cool air from the front of the rack. The cool
air is forced through the function blades, which typically contain a number of heat sinks, and
expelled through the vents on the rear of the rack.
It is very important to keep the air intake path on the front of the unit unobstructed and free of
debris.
It is also important to only operate the unit with all card slots covered to maintain the integrity of
the air flow. The MVE-R16 must have its front panel completely enclosed even when less than four
slots are taken by function blades. In this case the unused slots must be enclosed using blank panel
covers, part number BLE264-FP.
7.4
Order of populating blades into the MVE-R16 chassis
Blades can be inserted in any slot without any particular order.