CONFIDENTIAL
DOC-USR-0055-05
___________________________________________________________________________________________
Z3 Technology, LLC
♦
100 N 8
th
ST, STE 250
♦
Lincoln, NE 68508-1369 USA
♦
+1.402.323.0702
21
(3)
Connect an Ethernet cable connected through a hub or router to a PC to “Ethernet” on the Z3-
DM8107-SDI2-RPS.
(4)
Connect the supplied serial cable and gender changer to your PC and the Z3-DM8107-SDI2-RPS. (A
USB->Serial converter may be needed. If so, the FTDI UC232R-10 (Digikey part #768-1014-ND) is
recommended.)
7.3
Set up the Terminal Window
(5)
If you are running from a Windows PC, run TeraTerm. Select
“Setup – Serial Port” and set the
following:
Port:
The serial port the port is connected to
Baud Rate: 115200
Data:
8-bit
Parity:
None
Stop:
1-bit
Flow Control: None
(6)
If you are running from Linux, type:
# sudo minicom –s
And then configure by doing the following:
-Select “Serial Port Setup”
-Ensure the right Serial Device is specified (typically “/dev/ttyUSB0”)
-Set option E (“Bps/Par/Bits”) to 115200 8N1
-Press <return>