24
3
If the ZTS-100 is removed from the
network, it shows no connection.
Exclusion is completed.
4
Press
“
Home
"
key once to go
back to the home page.
Support Association Command Class
ZTS-100 support 2 association groups, each association group contains 5 nodes max. and up to 5
nodes can be assigned in these 2 association groups.
Association group_1:
z
ZTS-100 will send out basic set command 0xFF automatically once Heat Pump operation has been
started in heating mode.
z
ZTS-100 will send out basic set command 0x00 automatically once Heat Pump operation has been
stopped in heating mode.
Association group_2:
z
ZTS-100 will send out basic set command 0xFF automatically once Compressor operation has been
started in cooling mode.
z
ZTS-100 will send out basic set command 0x00 automatically once compressor operation has been
stopped in cooling mode.