Z-Wave PAN05-1B Quick Start Manual Download Page 5

 

Whenever the AC power reconnected to PAN05, it will set the switch to Off

On or 

Last switch state, default value is Last switch state.   

3-3 Manual On/Off Mode 

The On/Off function of S1

S2 and learn switch can be disabled or enabled by this 

parameter, default value is Enable. But the learning operation won’t be affected. 
When manual On/Off function is disabled, the RF command can only switch On 
but not Off. This is useful function for keeping the device in switch on state. 

3-4 LED indication Mode 

3-4-1 Show switch state

LED on for switch on and off for switch off. The default 

value is Show switch state. 

 

3-4-2 Show night mode

LED off for switch on and on for switch off. 

3-4-3 One Flash mode

When the state of switch changes, LED will be on only one 
second, then LED keeps off. 

 

3-5 Auto Off timer 

When auto off timer is equal to 0, the auto off function will be disabled. Whenever 
the switch is set to on, the auto off timer begin to count down. After the timer 
counts to zero, PAN05 will switch off automatically. The default value is disable 
auto off function.   

3-6 RF Off command mode 

Whenever a RF Off command is received, BASIC_SET

BINARY_SWITCH_SET

 

SWITCH_ALL_OFF, it could be interpreted as Switch Off

Switch On

Switch 

Toggle, or it would be ignored. The default value is Switch Off.   

 

4. Protection Command Classes 

PAN05 supports Protection Command Class version 2, it can protect the switch 

against unintentionally control by e.g. a child. And it can also protect the switch 

from being turned off by setting it in “No RF Control” state. 

After being set to “Protection by sequence” state, any intentional pressing of On/Off 

button or S1/S2 should be hold longer than 1 second, or the switch state will not 

change. 

However, the operation of learn function does not change, because learning will 

not be protected. 

 
5.  Command Classes 
 
The Switch supports Command Classes including… 
* COMMAND_CLASS_ZWAVEPLUS_INFO_V2 
* COMMAND_CLASS_VERSION_V2 
* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 
* COMMAND_CLASS_SECURITY 
* COMMAND_CLASS_DEVICE_RESET_LOCALLY 
* COMMAND_CLASS_ASSOCIATION_V2 
* COMMAND_CLASS_ASSOCIATION_GRP_INFO 
* COMMAND_CLASS_POWERLEVEL 
* COMMAND_CLASS_SWITCH_BINARY 
* COMMAND_CLASS_BASIC 
* COMMAND_CLASS_SWITCH_ALL 
* COMMAND_CLASS_CONFIGURATION 
* COMMAND_CLASS_ALARM 
* COMMAND_CLASS_PROTECTION_V2 
* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2

 

 
 
Troubleshooting 
                                 

 

Symptom 

Cause of Failure 

Recommendation

 

The Switch not working and 
LED off 

1.  The Switch is not 

connect to the Main 
power 

2.  The Switch break 

down 

1.  Check power connections 
2. Don’t open up the Switch and send 

it for repair.

 

The Switch LED 
illuminating, but cannot 
control the ON/OFF 
Switch of the load attached 

Check if the load connect 
into the Switch has its 
own ON/OFF switch 

Set the ON/OFF switch of the load 
attached to ON

 

The Switch LED 
illuminating, but the 
detector cannot control 
the Switch 

1. Not carry out 

association 

2. Same frequency 

interference 

1. Carry out association 
2. Wait for a while to re-try

 

LED keep flashing 

Overload occurs 

Remove the load attached or check 

Reviews: