Z-Wave PAN05-1B Quick Start Manual Download Page 4

 

For group 1, the Switch will report ON/OFF status of Relay to controller. 
 

2-1 Auto report to Grouping 1 (Maximum Node 1) 

 
2-1-1 On/Off Event Report   

      When  “on”  or  “off”  state  has  been  changed  (ex.  Press  S1  S2  or  include  on/off 

button), it will send Binary Switch Report to the nodes of Group1.   

       

Binary Switch Report 
 

ON:[Command Class Switch Binary, Switch Binary Report, Value 

=(255)0xFF] 

OFF:[Command Class Switch Binary, Switch Binary Report, Value 

=0(0x00)]

 

 

2-1-2 Overload alarm report command 

      When PAN05 detect the overload, it will send Alarm Report to the node of 

Group1. 

 
The content of Alarm Report 
 

Alarm report command:[Command Class Alarm, Alarm Report, Alarm Type 

= 0x08, Alarm Level = 0xFF]

 

 

2.  Z-Wave’s Configuration 
 

Configuration 
Parameter 

Function 

Size 
(Byte) 

Value 

Unit 

Default  Description

 

Edge or 
Pulse 
mode or 
Edge-Tog 
gle mode 

1-3 

 

1

 

1

Edge mode 

2

Pulse mode 

3

Edge-Toggle 

mode

 

Restore 
switch 
state 
mode 

0-2 

 

1

 

0 : Switch Off 
1 : Last Switch 

State 

2 : Switch On

 

Manual 
On/Off 
mode 

0-1 

 

1

 

0

Disable 

manual On/Off 

1

Enable 

manual On/Off

 

LED 
indication 
mode 

1-3 

 

1

 

1

Show switch 

state 

2

Show night 

mode 

3 : One flash 

mode

 

Auto off 
timer 

0-0x7F
FF

 

Second

  0

 

0

Disable auto 

off function 

1-0x7FFF

1 ~ 

32767seconds

 

RF Off 
command 
mode 

0-3 

 

0

 

0

Switch off 

1

Ignore 

2

Switch toggle 

3

Switch on

 

 

3-1 Edge / Pulse / Edge-Toggle mode 

Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle 

mode, default value is Edge mode. 

3-1-1 Edge mode: this mode is suitable for the bi stable wall switch that has indicator 

point on the switch, and the same position correspond to same state of relay1. 

if the PAN05 relay change the state because of receiving Z-Wave RF 

command, it may need two times of change (switch on to off or switch off to on) 

to let relay back to the correspond state. Manual switch S2 is disabled in 

this mode. 

3-1-2 Pulse mode: this mode is suitable for the toggle type wall switch to swap the 

state of Relay1. 

3-1-3 Edge-Toggle mode: this mode is suitable for the normal bi-stable switch, every 

time when change the state of the wall switch will also swap the state of 

Relay1.       

3-2 Restore Switch State Mode 