Association

3.

 

The PAC01 is an always listening 

Z-Wave device, so associations 

may be added or removed by a con-

troller at any time. Or If your con-

troller requires to have the PAC01 

send a 'node information frame' or 

NIF for associations, then pressing 

the On/Off button three times within 

2 seconds will cause the PAC01 to 

send its NIF.

Adding a node ID allocated by Z-Wave Controller means inclusion. Removing a node

ID allocated by Z-Wave Controller means exclusion.

Failed or success in including/excluding the node ID can be viewed from the Z-Wave 

Controller. 

LED Indication

To distinguish what mode the switch is in, view from the LED for identification.

State Type

LED Indication

Normal

Whenever we press button to PAC01, the LED will on; Otherwise the 

LED is off.

No node ID

Under normal operation, when the Switch has not been allocated a 

node ID, the LED flashes on and off alternately at 2-second intervals. 

Learning

When 

PAC01

 is in learning mode, LED flashes on and off alternately 

and repeatedly at 2 second intervals.

Programming

1. Basic Command Class / Thermostat Setbac Command Class

PAC01 will respond to BASIC and THERMOSTAT_SETBACK commands that are 

part of the Z-Wave system. If PAC01 is included as a secured node, it will only re-

sponse to the security encapsulation command of BASIC and THERMOSTAT_SET-

BACK.

1-1 BASIC_GET 

Upon receipt of the following commands from a Z-Wave Controller, the Adapter will

report its state to the node inquired.

Basic Get Command: 

[Command Class Basic, Basic Get]

Basic Report Command:

Report Energy Saving Mode: 

[Command Class Basic, Basic Report, Value = 0]

Report Comfort Mode:

[Command Class Basic, Basic Report, Value = 0xFF]

1-2 BASIC_SET / THERMOSTAT_SETBACK_SET

Upon receipt of the following commands from a Z-Wave Controller

[Command Class Basic, Basic Set, Value = 0] : 

Set off.

[Command Class Basic, Basic Set, Value = 0xFF] :  

Set On

[Command Class Thermostat Setback, Thermostat Setback Set, properties1=2,

setbackState = 128~255] :  

Set off.

[Command Class Thermostat Setback, Thermostat Setback Set, Sproperties1 

≠2 , setbackState = 0~126] : 

Set On

1. 

Z-Wave’s Groups 

The Adapter can be set to send reports to associated Z-Wave devices. It supports 

one association group with one nodes support for grouping 1. For group 1, the 

4