Z-Wave PAC01 Installation Download Page 2

908.4MHz & 916.0MHz / USA (PAC01-US);

922.50 MHz, 923.90 MHz, 926.30 MHz / JAPAN 

(PAC01-JP);

RF Maximum Power

+5dBm 

Transmission Range

Minimum 40 m in door 100m outdoor line of sight

Location 

Indoor use only

** Specifications are subject to change and improvement without notice.              

Troubleshooting

       

Symptom

Cause of Failure

Recommendation

The Adapter does not 

work and LED off

1.The Adapter does not connect 

the electrical wire properly

2.The Adapter break down

1. Check power connections

2. Don’t open up the Adapter 

and send it for repair.

The Adapter cannot 

report to the group

1. Not carry out association

2. Same frequency interference

1. Carry out association

2. Wait for a while to re-try

For Instruction to http:// www.philio-tech.com

Installation

 

                                              

Fig 1. PAN10 Assembling

DANGER

      

Danger of electrocution!

All works on the device may be performed only by a qualified and licensed 

electrician. Observe national regulations. 

Any works introducing changes into the configuration must be always performed 

with disconnected voltage. 

2