background image

 

Note: When the battery is connected, HSD-200Z needs a warming-up duration, 
during  that,  it  will  release  a  short  beep  every  3  seconds.  Once  the  Motion 
Sensor  has  stabilized,  the  LED  behind  the  lens  will  illuminate  red  for  5 
seconds with a long beep can be heard. 
 
3. Recover the default setting: 

 

Press the  learning key more than 3 seconds and release,  and then  press it again 
more than 6 seconds. Within the six seconds, it will beep shortly once every second 
and end with a long beep which means all setting is recovered to default as shown 
below: 

 

Mode 

Security Mode 

PIR function 

Enable (System ON) 

PIR Sensitivity 

Level  4  (  The  farthest  distance  of 
detection is 10M/32.81ft)

 

PIR Re-trigger interval 

5 seconds 

Time-off setting 

2 minutes 

Light Sensor Threshold 

15% 

 
 
4. PIR Adjustable Sensitivity level setting: 

 

In order to provide the best efficiency of HSD-200Z, it is recommend that to test the 
movement  PIR  can  detect  from  the  farthest  end  of  the  coverage  area  at  the  first 
time use. There will be ten sensitivity levels can be defined and set at user

’s own 

choice.You  can  define  it  referring  the  table  below.  (10  represent  the  maximum 
sensitivity,  1  means  the  least  sensitivity  ).The  maximum  sensitivity  setting  of  the 
detector is suitable for long range detection which can be used in larger room.         
       
              Sensitivity Level definition:   
 

Level 

Wall-Mounted 

Ceiling-Mounted 

1~4 

~10m 

~5m 

4~10 

10m~15m 

5m~6m 

 

 

 

Configuration Command 

Message 

Parameter 

Number 

Size 

Range 

Default 

PIR sensitivity level 

1~10 

 
 
5. Time-off setting: 

 
The stayed 

“ON” duration of activated lamps or appliances can be set by user from 

5 seconds to 60 minutes via a controller. As long as HSD-200Z is triggered, it will 
emit a ZWave ON Command to associated units wait until the time set is terminated, 
HSD-200Z  will  send  a  ZWave  OFF  Command  to  the  associated  units.  It  means 
whatever you like, you can determine for 

“how long “the units be connected should 

be stayed 

”ON” mode after it is triggered.   

 

Configuration Command 

Message 

Parameter 

Number 

Size 

Range 

Default 

Trigger time-off 

interval 

#b 

1~2 

5~3600 

120 

#b (when value larger than 255, the size would be 2) 

 
6. Low Battery Indication:       

 

When  the  battery  power  of  HSD-200Z  is  low,  it  will  emit  a  Z  Wave  Low  battery 
command to compatible controller; meanwhile, the LED of HSD-200Z will flash once 
every 30 seconds.     

 
7. Wakeup Command Class 
 

The  Motion  Detector  will  send  a  Wakeup  Notification  Command  if  it  has  been 
included  into  a  Z-Wave  network.  The  prerequisite  is  the  connected  Z-Wave 
controller needs to emit a node ID and wakeup time interval to the Detector.

 

 

The Motion Detector will wake up periodically as desired depending on time interval 

Reviews: