4
Note: When the battery is connected, HSD-200Z needs a warming-up duration,
during that, it will release a short beep every 3 seconds. Once the Motion
Sensor has stabilized, the LED behind the lens will illuminate red for 5
seconds with a long beep can be heard.
3. Recover the default setting:
Press the learning key more than 3 seconds and release, and then press it again
more than 6 seconds. Within the six seconds, it will beep shortly once every second
and end with a long beep which means all setting is recovered to default as shown
below:
Mode
Security Mode
PIR function
Enable (System ON)
PIR Sensitivity
Level 4 ( The farthest distance of
detection is 10M/32.81ft)
PIR Re-trigger interval
5 seconds
Time-off setting
2 minutes
Light Sensor Threshold
15%
4. PIR Adjustable Sensitivity level setting:
In order to provide the best efficiency of HSD-200Z, it is recommend that to test the
movement PIR can detect from the farthest end of the coverage area at the first
time use. There will be ten sensitivity levels can be defined and set at user
’s own
choice.You can define it referring the table below. (10 represent the maximum
sensitivity, 1 means the least sensitivity ).The maximum sensitivity setting of the
detector is suitable for long range detection which can be used in larger room.
Sensitivity Level definition:
Level
Wall-Mounted
Ceiling-Mounted
1~4
~10m
~5m
4~10
10m~15m
5m~6m
Configuration Command
Message
Parameter
Number
Size
Range
Default
PIR sensitivity level
4
1
1~10
4
5. Time-off setting:
The stayed
“ON” duration of activated lamps or appliances can be set by user from
5 seconds to 60 minutes via a controller. As long as HSD-200Z is triggered, it will
emit a ZWave ON Command to associated units wait until the time set is terminated,
HSD-200Z will send a ZWave OFF Command to the associated units. It means
whatever you like, you can determine for
“how long “the units be connected should
be stayed
”ON” mode after it is triggered.
Configuration Command
Message
Parameter
Number
Size
Range
Default
Trigger time-off
interval
7
#b
1~2
5~3600
120
#b (when value larger than 255, the size would be 2)
6. Low Battery Indication:
When the battery power of HSD-200Z is low, it will emit a Z Wave Low battery
command to compatible controller; meanwhile, the LED of HSD-200Z will flash once
every 30 seconds.
7. Wakeup Command Class
The Motion Detector will send a Wakeup Notification Command if it has been
included into a Z-Wave network. The prerequisite is the connected Z-Wave
controller needs to emit a node ID and wakeup time interval to the Detector.
The Motion Detector will wake up periodically as desired depending on time interval