3
FIGURE 4b
FIGURE4c
1. Use a screwdriver to undo the bracket.
2. Insert 3 AA-size 1.5V alkaline batteries to the battery compartment, ensuring
that correct polarity is put.
3. Hold the bracket in position and mark the two mounting holes. Drill the holes,
insert the plastic wall plugs and screw the bracket to the ceiling using the
screws supplied.
4. Engage the HSD-200Z detector to the bracket firmly.
Note:
After removing batteries, wait for 30 seconds to refit batteries.
Operation
HSD-200Z has two modes variable via a controller: (
Ⅰ
) Security Mode (
Ⅱ
) Home
Automation Mode. The default setting is for security mode, but you can switch to
your desired mode via a controller. Some general operations are similar in both
modes which are listed below (1~7). As for the parameter settings, it will need
someone who has experience setting up a Z-Wave system or someone that has
computer software running a Z-Wave controller.
Configure Command
Message
Parameter
Number
Size
Range
Default
Security Mode /
Home Automation
Mode
2
1/1
1/2
1(Security
Mode)
1. Enable
The HSD-200Z is set to be controlled by a Z-wave controller or other compatible
units, use a controller to emit a signal of
“System On” to HSD-200Z to enable PIR
and Light sensor function. Upon motion/preset darkness level being sensed, the
Detector will turn ON the load or the lamp connected.
2. Disable
The HSD-200Z is set to be controlled by a controller or other compatible units, use a
controller to emit a signal of
“System Off” to HSD-200Z to disable PIR and Light
sensor function.
Configure Command
Message
Parameter
Number
Size
Range
Default
System On/Off
3
1/1
1/0
1(System On)