CT200-G1 User Guide
Table 10: Source
Value
Configuration
0x01
C-Wire
0x02
Batteries
Humidity Reporting Threshold
The Humidity Reporting Threshold parameter specifies the threshold change in the relative
humidity as detected by the thermostat to trigger an unsolicited report when association
reporting is enabled.
Table 11: Humidity Reporting Threshold
Name
Value
Parameter (8-bit)
0x05
Size (3-bit)
0x01
Configuration Values (8-bit)
Configuration values are bit-encoded.
Table 12: Threshold
Value
Configuration
0x00
Disabled Reporting
0x01
3% Relative Humidity (DEFAULT)
0x02
5% Relative Humidity
0x03
10% Relative Humidity
Auxiliary Heat
The Auxiliary Heat parameter enables or disables Thermostat Mode called Auxiliary Heating
in the thermostat while the thermostat mode is Heat.
Enabling Auxiliary Heat parameter will only use the auxiliary heating HVAC subsystem to
maintain the room temperature using the thermostat heating setpoint. The heat pump will
not be used to maintain the room temperature.
Auxiliary heating is only available if the thermostat is configured in heat pump mode and with
at least one stage of auxiliary heating. This command should only be used on thermostats
that support Auxiliary Heat thermostat mode.
Table 13: Auxiliary Heat
Name
Value
Parameter (8-bit)
0x06
Size (3-bit)
0x01
Configuration Values (8-bit)
Configuration values are bit-encoded.
Table 14: Auxiliary Heat
Value
Configuration
0x00
Disabled auxiliary heat (DEFAULT)
0x01
Enabled auxiliary heat
24
Chapter 3. Z-Wave Reference
Summary of Contents for CT200-G1
Page 1: ...CT200 G1 User Guide Radio Thermostat Jul 29 2019 ...
Page 2: ......
Page 4: ...ii ...
Page 18: ...CT200 G1 User Guide 14 Chapter 1 Installation Guide ...