YZ Systems Milton Roy • 201 Ivyland Road • Ivyland, Pennsylvania • USA • 18974 • P: 281.362.6500 • www.yzsystems.com
Page 2
NJEX EUR ver.08-2021
Section 1: First Things To Know About The NJEX
1
Actual reserve time is dependant on age and condition of battery and the usage rate of the NJEX System.
Operation Specifications
Maximum Odorant Output:
6300G:
6.7 liters/day
7300G:
67 liters/day
Maximum Operating Pressure: 99.28 Bar (g)
Operating Temp Range:
-17°C to 60°C
Power Supply:
Customer Supplied
intrinsically safe
24VDC per control
diagram.
Gas Flow Rate Input Signal: 1-5 VDC, 4-20 mA or
pulse
Note: at temperatures below 0º C, conditioning of
the actuation gas supply may be required. Where the
actuation gas supply has a high water content and/or
a low hydrocarbon dew point, additional actuation gas
filtration or heating of the actuation gas supply may be
necessary. Bottled nitrogen can also be used during
cold operating conditions to avoid condensation in
the actuation gas supply line. In addition, operation at
extreme temperatures will affect seal and diaphragm
performance. To prolong the service of seals and dia-
phragm, adequate heat should be provided to main-
tain an operating environment above -1º C.
NJEX Systems are approved to Zone 1, IIB, T4 and
must be installed grounded, wired, and I.S. Barrier
Protected in accordance with all applicable electrical
codes.
Warranty
Please visit our web site www.yzsystems.com for a
complete copy of our warranty contained in our Terms
and Agreement document.
Summary of Contents for NJEX 6300G
Page 1: ...NJEX 6300G 7300G N A T U R A L G A S O D O R I Z A T I O N S Y S T E M...
Page 2: ......
Page 3: ...NJEX 6300G 7300G Instruction Operating Manual Version 08 2021...
Page 4: ......
Page 10: ......