8
6.1 Variable pressure/constant volume cylinders.
Spun cylinders may be installed in a horizontal
position on the DynaPak BackRack vessel rack.
Avoiding traps in the line, install stainless steel tubing
and fittings from the sample discharge port of the
sampler to the product end of the sample cylinder.
300cc and 500cc spun cylinders may also be in-
stalled in a vertical position. Piping from the sampler
dischage port to the sample vessel should be
arranged so that liquid traps are not created.
6.2 Variable volume/constant pressure cylinder.
The free-floating piston cylinder (DuraSite) may be
installed in a horizontal position on an optional vessel
rack. Free-floating piston cylinders should NOT be
installed on the DynaPak BackRack vessel rack.
Install 1/8" tubing from the sample discharge port of
the manifold to the product end of the vessel. Avoid
traps in this line.
See diagram #9 for DuraSite portable sample vessel
instructions.
6.3 LinkPlus. Install the optional LinkPlus directly
into the sample discharge port of the sampler. Use
stainless steel tubing and fittings to connect the
LinkPlus outlet to the product end of the sample
cylinder.
6. Sample Vessel Installation