DP-2010RXNLF 08202001 ATEX Rev.
YZ Systems, Inc. • 3101 Pollok Drive • Conroe, Texas • USA • 77303 • P: 936.788.5793 • F: 936.788.5720
13
8.4 Turn mode switch 1 to on.
8.5 Turn mode switch 2 to on.
8.6 Turn mode switch 3 to on.
8.7 Turn mode switch 4 to off.
8.8 Press the test button once to initiate the timer
sequence.
8.3 Adjust the pump volume adjustment knob to
the value used in the calculations in step 8.1.
Number of turns open on the pump volume knob
3
6
12
Sample pump displacement per stroke
.1cc
.2cc
.4cc
System
Mutual
Approved
Factory
8. Sampler Set-Up - Time-based sampling