Electromagnetic compatibility information

For ME EQUIPMENT and ME SYSTEMS that are
not LIFE-SUPPORTING

Table 3

Guidance and manufacture s declaration-electromagnetic immunity

The YE680B is intended for use in the electromagnetic environment 

specified below. The customer or the user of YE680B  should assure 

that it is used in such an environment.

Immunity

test

IEC 60601 

test level

Compliance

level

3 Vrms

0,15 MHz-80 MHz

6 V rms in ISM and amateur

radio bands between 

0,15 MHz and 80 MHz

80 % Am at 1 kHz

Conducted RF

IEC 61000-4-6

NOTE1  At

 

80

 

MHz

 

and

 

800

 

MHz

the

 

higher

 

frequency

 

range

 

applies

.

NOTE2  These

 

guidelines

 

may

 

not

 

apply

 

in

 

all

 

situations

Electromagnetic

 

propagation

 

is

 

affected

 

by

 

absorption

 

and

 

reflection

 

from

 

structures

objects

 

and

 

people

.

Field

 

strengths

 

from

 

fixed

 

transmitters

such

 

as

 

base

 

stations

 

for

 

radio

 (

cellular

/

cordless

telephones

 

and

 

land

 

mobile

 

radios

amateur

 

radio

AM and

 

FM

 

radio

 

broadcast

 

and

 

TV

 

broadcast

 

cannot

 

be

 

predicted

 

theoretically

 

with

 

accuracy

To

 

assess

 

the

 

electromagnetic

 

environment

 

due

 

to fixed

 

RF

 

transmitters

an

 

electromagnetic

 

site

 

survey

 

should

 

be

 

considered

If

 

the

 

measured

 

field

 

strength

 

in

 

the

 

location

 

in

 

which

 

the

 

YE680B

 

is

 

used exceeds

 

the

 

applicable

 

RF

 

compliance

 

level

 

above

the

 

YE680B

 

should

 

be

 

observed

 

to

 

verify

 

normal

 

operation

If

 

abnormal

 

performance

 

is

 

observed

,

additional

 

measures

 

may

 

be

 

necessary

such

 

as

 

reorienting

 

or

 

relocating

 

the 

YE680B

.

 

b

Over

 

the

 

frequency

 

range

 

150

 

kHz

 

to

 

80

 

MHz

field

 

strengths

 

should

 

be

 

less

 

than

 

3

 

V

/

m

.

Radiated RF

IEC 61000-4-3

10 V/m

80 MHz to

2.7 GHz

3 Vrms

0,15 MHz-80 MHz

6 V rms in ISM and amateur

radio bands between 

0,15 MHz and 80 MHz

80 % Am at 1 kHz

10 V/m

80 MHz to

2.7 GHz

         

              

a)

Band

(MHz)

a)

Service

(MHz)

Modulation

b)

Maximum

power

(MHz)

IMMUNITY

TEST LEVEL

(V/m)

Distance

(m)

380-390

TETRA 400

Pulse

b)

modulation

18 Hz

1,8

0,3

27

385

430-470

FM

±5 kHz deviation

1  kHz sine

  2

28

450

GMRS 460,

FRS 460

0,3

710

704-787

LTE Band 13,

17

       

0,3

 9

745

780

    Pulse

b)

modulation

217 Hz

  0

,

2

810

800-960

GSM 800/900,

TETRA 800,

iDEN 820,

CDMA 850,

LTE Band 5

       

0,3

 28

930

Pulse

b)

modulation

18 Hz

  2

1720

1700-1990

GSM 1800;

TETRA 1900;

GSM 1900;

DECT;

LTE Band 1,3,

4,25; UMTS

0,3

 28

1970

Pulse

b)

modulation

217 Hz

  2

870

1845

Bluetooth,

WLAN,

802.11 b/g/n

RFID 2450,

LTE Band 7

0,3

2450

Pulse

b)

modulation

217 Hz

2400-2570

  2

 28

WLAN 

802.11a/n

0,3

Pulse

b)

modulation

217 Hz

5240

5500

5785

5100-5800

  0

,

2

9

NOTE       If necesary to achieve the IMMUNITY TEST LEVEL, the distance between the transmitting 

antenna and theME EQUIPMENT or ME SYSTEM may be reduced to 1 m. The 1 m test distance is permitted by 

IEC61000-4-3.

   

b

a)  For some services, only the uplink frequencies are included.

b)  The carrier shall be modulated using a 50% duty cycle square wave signal.、

c)  As an alternative to FM modulation, 50% pulse modulation at 18 Hz may be used because while it 

does not 

frequency

(MHz)

Test

Table 4-Test specifications for ENCLOSURE

 P

ORT

  

IMMUNITY to RF wireless communications 
equipment

Electromagnetic compatibility information

42

43

Summary of Contents for YE680B

Page 1: ...ng Jiangsu Province P R China 210000 Manufacturing Address YunYang Industrial Park DanYang Jiangsu Province P R China 212300 http www yuwell com Please read the user s manual closely before using YE68...

Page 2: ...Auxiliary measuring function Static mode Common problems Common questions of blood Pressure measurement Common fault and trouble shooting Technical parameters Health diary Electromagnetic compatibilit...

Page 3: ...cover Power on Operation guide 1 Using method of cuff Wearing the cuff and make the lower edge 2 3cm above the elbow keep the air tube inside of the arm Please turn to page 19 for details 2 3cm Measur...

Page 4: ...s the button of check the measuring records This monitor can display the average measurement and store 99 records Please turn to page 24 for details 1 Main part Display Member button Memory button Sta...

Page 5: ...A MFR JIANGSU CHENYANG ELECTRON CO LTD US Model CYSM06 060060 UL C EU Model CYSM06 060060 CE C 4 User s manual Warranty card 4xAA batteries SYS systolic Pulse rate Low voltage Blood pressure level dis...

Page 6: ...pulse rate of adult at household or medical center not suitable for neonate pregnancy or pre eclampsia Pay attention to the following points when measuring or it may cause the incorrect results Sit s...

Page 7: ...he CUFF over a wound arm or being on an intravenous drip Consult your doctor if using the device on the arm with an arterio venous A V shunt Do not use the cuff on the arm where the side of a mastecto...

Page 8: ...ing items to protect the device and ensure the accuracy of measurement We suggest to calibrate the monitor at least once a year according to local laws and regulations Please contact the manufacturer...

Page 9: ...r setting Press the button and for more than 3 seconds till the number starts flashing 2 The year increase once press the button 3 Press the button to switch to the month setting 4 Using the same way...

Page 10: ...unit setting Press the button to switch between these two pressure units Finish by pressing the button After finishing the volume setting pressing After unit setting press the button to shut down Pres...

Page 11: ...enter of cuff and heart at the same level Also please ensure the air tube not twisted Using method of cuff Wind the cuff around the upper arm as shown Stick the cuff tightly Note The cuff should be we...

Page 12: ...en table and chair is 25 30cm back and arm being supported Sit on a chair with your feet flat on the floor Don t eat smoke drink take bath or do any high impact sport within half an hour before measur...

Page 13: ...pressure release value starts to decrease gradually 2 Measurement finished After measurement the monitor will show the SYS DIA and pulse rate then inflate the air automatically m MEMBER SYS mmHg DIA m...

Page 14: ...terval between two measurements should be at least 5 minutes or longer Estimate the blood pressure condition according to the BP classification table and consult the doctor Blood pressure range indica...

Page 15: ...e measurement need stoping for uncomfortableness or other reasons please press the button the measurement will stop immediately and air releases fast Take off the cuff manually if the button is not wo...

Page 16: ...ed data by pressing the button as the sequence 1 2 99 max D Press the button to shut off the monitor 2 Delete the recorded data If the cuff winded properly it will show the icon Otherwise it will show...

Page 17: ...press the button to stop inflating and take out the batteries to enter the next step System restores Static mode Press the button and hold meanwhile install the batteries Hold on for about 3 seconds...

Page 18: ...2 33 kPa mmHg k a mmHg P 12 0 18 5kPa 90 139mmHg 18 7 21 2kPa 140 159mmHf 12 0 13 2kPa 90 99mmHg 21 3 23 9kPa 160 179mmHg 13 3 14 5kPa 100 109mmHg 24 0kPa 180mmHg 14 7kPa 110mmHg 8 0 11 9kPa 60 89mmHg...

Page 19: ...In hypertensive individuals variations are even more pronounced Normally the blood pressure rises while at work or play and falls to its lowest levels during sleep So do not be overly concerned by the...

Page 20: ...The icon twinkle 36 37 300mmHg...

Page 21: ...sification Service life Weight Dimension Operating temperature Humidity Storage temper ature Humidity Operating Storage atmospheric pressure 70kPa to 106kPa There is the potentia risk of radio frequen...

Page 22: ...nment YE680B Immunity test IEC 60601 test level Compliance level Electrostatic discharge ESD IEC 61000 4 2 Electrical fasttransient burst IEC 61000 4 4 2 kV 100kHz repetition frequency Surge IEC 61000...

Page 23: ...relocating the YE680B b Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m Radiated RF IEC 61000 4 3 10 V m 80 MHz to 2 7 GHz 3 Vrms 0 15 MHz 80 MHz 6 V rms in ISM an...

Page 24: ...44 45 Health diary Health diary...

Reviews: