background image

Page 7 of 9

PIAZZA PATIO HEATER

10/04/07

SERVICING

Only authorised service technicians should undertake any repairs or Maintenance

on this product.

A detailed drawing of the gas components in this product is shown below. Part

numbers can be used to order replacement parts, if needed.

To access these components the perforated sheet metal cylinder that surrounds

the  control  must  be  removed.  This  is  done  by  removing  the  screws  top  and

bottom and the channel section pilot pipe cover.

As  with  all  gas  appliances,  regular  servicing  will  improve  the  trouble  free

operation of this appliance. This service should cover the following

- Leak test all joints

- Check operating pressures

- Clean main and pilot orifices

- Clean main burner venturi as insects and dirt may gather there.

- Inspect flexible gas hose

- Brush any soot etc. that may have gathered on stainless steel mesh.

Please fill out the warranty card (page 9) and return it to your retailing Yunca

agent.

Summary of Contents for PIAZZA

Page 1: ...Page 1 of 9 PIAZZA PATIO HEATER 10 04 07 PIAZZA All SEASONS PATIO HEATER APRIL 2007 OPERATIONS MAINTENANCE WARRANTY INFORMATION...

Page 2: ...ld stay with the appliance and is for the reference of the user and service person Only authorised service technicians should undertake any repairs or maintenance on this product It is recommended tha...

Page 3: ...EGS TO LEG COLUMN SUPPORT 2 BOLT LEGS TO BASE 3 SLIDE CYLINDER ON TO POLE 4 POSITION COLUMN PIPE TO SOCKET 5 ALIGN HOLES SO THAT THE BOLT CAN PASS THROUGH 6 SECURE POLE INTO POSITION USING LOCK NUT 7...

Page 4: ...ater will effectively heat a radius of around 3M so its position should be chosen to allow efficient use of heat without impeding peoples movement The clearances shown below should be maintained at al...

Page 5: ...connected to an approved bayonet fitting or permanently mounted and piped To get the maximum life from this product we suggest that it is stored in a covered position If the heater is being installed...

Page 6: ...to the flame setting required Changing a bottle LPG When the flame turns abnormally yellow and becomes smaller it is time to change the gas bottle To do this simply slide the round cylinder cover up...

Page 7: ...l must be removed This is done by removing the screws top and bottom and the channel section pilot pipe cover As with all gas appliances regular servicing will improve the trouble free operation of th...

Page 8: ...y for incidental and consequential damage directly or indirectly sustained or for any loss caused by the application of this product not in accordance with the current printed instructions Our liabili...

Page 9: ...urchased Installed By If permanent installation Date Yunca Gas PO Box 500 Dunedin 9054 Ph 03 488 4342 Email yuncagas southnet co nz Cut along this line This section must be returned within 10 days of...