Lighting instructions

1. 

Ensure that bottle is connected and supply valve open (LPG).

2. 

Press control knob in and turn to pilot setting.

3.

Hold control knob in and 

allow at least one and a half minutes

 for air to

purge from gas line. Slightly tilting the heater will assist the air to purge.

4.

While still pressing knob, turn to “star” setting.

5.

If the pilot has not ignited, repeat the procedure.

6.

The knob must be held in at the “star” setting for a further 20 seconds to

allow flame  failure device to engage.

7.

Release knob (slowly) and turn to the flame setting required.

Changing a bottle (LPG).

When  the  flame  turns  abnormally  yellow  and  becomes  smaller  it  is  time  to

change the gas bottle. To do this simply slide the round cylinder cover up the

main stem to expose the gas cylinder. Remove the leg held on with a wing nut.

Disconnect regulator from the bottle and exchange bottles.

Dome Removal.

The reflective dome is designed to be easily removed so the Patio Heater can be

wheeled through doorways etc. This should 

only

 be done after the heater has

been off for sufficient time to 

fully cool down

.

Abnormal performance.

If at any time the Patio Heater exhibits any problem or abnormal noise it should

be immediately turned off. The Patio heater should be checked and tested by

authorised service technician before being used.

Summary of Contents for PIAZZA

Page 1: ...Page 1 of 9 PIAZZA PATIO HEATER 10 04 07 PIAZZA All SEASONS PATIO HEATER APRIL 2007 OPERATIONS MAINTENANCE WARRANTY INFORMATION...

Page 2: ...ld stay with the appliance and is for the reference of the user and service person Only authorised service technicians should undertake any repairs or maintenance on this product It is recommended tha...

Page 3: ...EGS TO LEG COLUMN SUPPORT 2 BOLT LEGS TO BASE 3 SLIDE CYLINDER ON TO POLE 4 POSITION COLUMN PIPE TO SOCKET 5 ALIGN HOLES SO THAT THE BOLT CAN PASS THROUGH 6 SECURE POLE INTO POSITION USING LOCK NUT 7...

Page 4: ...ater will effectively heat a radius of around 3M so its position should be chosen to allow efficient use of heat without impeding peoples movement The clearances shown below should be maintained at al...

Page 5: ...connected to an approved bayonet fitting or permanently mounted and piped To get the maximum life from this product we suggest that it is stored in a covered position If the heater is being installed...

Page 6: ...to the flame setting required Changing a bottle LPG When the flame turns abnormally yellow and becomes smaller it is time to change the gas bottle To do this simply slide the round cylinder cover up...

Page 7: ...l must be removed This is done by removing the screws top and bottom and the channel section pilot pipe cover As with all gas appliances regular servicing will improve the trouble free operation of th...

Page 8: ...y for incidental and consequential damage directly or indirectly sustained or for any loss caused by the application of this product not in accordance with the current printed instructions Our liabili...

Page 9: ...urchased Installed By If permanent installation Date Yunca Gas PO Box 500 Dunedin 9054 Ph 03 488 4342 Email yuncagas southnet co nz Cut along this line This section must be returned within 10 days of...

Reviews: