FIG E: FLUE SYSTEM REQUIREMENTS 

(not to scale) 

 

 

More than 3000

3000

or less

6

0

0

 m

in

.

3000

1000 min. if clear

within 3000 of
flue top

.

3000

Any nearby

structure

.

1000 min. if clear

within 3000 of
flue top

MINIMUM HEIGHT OF FLUE SYSTEM EXIT

NOTE : Dimensions are in millimetres

3000

or less

6

0

0

 m

in

.

More than 3000

3000

.

Increase from
1000 min. until

clear within
3000 of flue top

 

IMPORTANT INFORMATION 

 

A. 

THE APPLIANCE AND FLUE SYSTEM SHALL BE INSTALLED IN COMPLIANCE WITH AS/NZS 
2918:2001 AND THE APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING CODE OR 
CODES. 

B. 

APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD SHALL COMPLY WITH THE 
REQUIREMENTS OF AS/NZS 4013 WHERE REQUIRED BY THE REGULATORY AUTHORITY I.E. 
THE APPLIANCE SHALL BE IDENTIFIABLE BY A COMPLIANCE PLATE WITH THE MARKING 
“TESTED TO AS/NZS 4013” 

C. 

ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY 
THE TESTING AUTHORITY IS CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED 
FOR COMPLIANCE WITH AS/NZS 4013 

D. 

MIXING OF APPLIANCE OR FLUE SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR 
MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT IN 
HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS CONSIDERED, THE MANUFACTURER 
SHOULD BE CONSULTED IN THE FIRST INSTANCE. 

E. 

CRACKED AND BROKEN COMPONENTS E.G. GLASS PANELS OR FIRE BRICKS, MAY RENDER 
THE INSTALLATION UNSAFE. 

IF A WATERBOOSTER IS FITTED: 

NOTE: A WATER BOOSTER CAN ONLY BE FITTED T

O THE “WET” VERSION OF THIS UNIT 

WHEN IN CLEAN AIR ZONES (CHECK LOCAL COUNCIL REGULATIONS) 

 

A.  DO NOT CONNECT TO AN UNVENTED HOT WATER SYSTEM  

B.  INSTALL IN ACCORDANCE WITH AS 3500.4.1 OR NZS 4603 AND THE APPROPRIATE 

REQUIREMENTS OF THE RELEVANT BUILDING CODES. 

SEISMIC RESTRAINT

   

Secure the heater base to the hearth or sub-framing with Dynabolts or similar.  

Follow local Council’s Specifications. 

Summary of Contents for MONTE BASE Clean Air Sub 1.0

Page 1: ...straint E Manufacturers recommended tested minimum clearances from combustible walls Tested to AS NZS 2918 2001 by APPLIED RESEARCH SERVICES LTD Clearance Rear Clearance with YUNCA STD FLUE GUARD fitted 200mm Side Clearance with YUNCA STD FLUE GUARD fitted 450mm Corner Clearance with YUNCA STD FLUE GUARD fitted 280mm F YUNCA Flue Kit Complies with AS NZS 2918 2001 Appendix F FIG A B E 1 4 2m x 150...

Page 2: ...ss than 600mm above the highest point on the roof if within 3 0m of that point or Not less than 1000mm above the intersection point with the roof and not lower than any point of the roof within 3 0m In any case the length of the flue shall not be less than 4 6m from the ash floor protector In some situations the Local Council may vary the above requirements 2 The flue system must be tested and com...

Page 3: ...UNTED SHIELD FITTED Measurements in millimetres A B E F G H 200 450 280 366 782 600 FIG D MINIMUM FLOOR PROTECTION MEASUREMENTS WITH YUNCA FLUE MOUNTED SHIELD FITTED Measurements in millimetres C D J K L M N O P 300 125 913 999 1481 1288 633 663 699 Note All Dimensions are in millimetres Above Non combustible wall clearances Brick lining From the floor to within 25mm of ceiling Leave air vents at ...

Page 4: ...E MARKING TESTED TO AS NZS 4013 C ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE WITH AS NZS 4013 D MIXING OF APPLIANCE OR FLUE SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT IN HAZARDOUS CONDITIONS WHERE SUCH ACTION IS...