FIG. C: HEATER DIMENSIONS & WATER BOOSTER POSITION 

– 

 MONTE BASE WOODBURNER 

(not to scale)   

 

  

Note: A water booster shall be fitted only with “Wet” model installations unless otherwise allowed by Regional Council rules.  

 

 

FIG. D: HEATER POSITION. 

(Not to scale)

             

 

         

        

 

 
 
 

     

          

         

 
 

 

       

 

 
 
 
 

 

FIG E: FLUE SYSTEM REQUIREMENTS 

(not to scale) 

 

FIG D: MINIMUM FIRE TO COMBUSTABLE WALL CLEARANCES - MONTE WOOD-BURNER

 

(WITH YUNCA FLUE MOUNTED SHIELD FITTED). Measurements in millimetres. 

 

 

 

200 

450 

280 

366 

782 

600 

 

 

 

 

FIG D: MINIMUM FLOOR PROTECTION MEASUREMENTS

  

(WITH YUNCA FLUE MOUNTED SHIELD FITTED). Measurements in millimetres. 

300 

125 

913 

999 

1481 

1288 

633 

663 

699 

 

Note! All Dimensions are in millimetres 

Above: Non combustible wall clearances

. Brick lining.  From the floor to within 25mm of ceiling. Leave air vents 

at the bottom to allow airflow in the cavity.   If Yunca flue mounted shield is fitted, brickwork may be 1200mm high 
as long as all vertical joints in top and bottom of brickwork are left out to allow airflow when brickwork is capped. 

847

 

 

Summary of Contents for MONTE BASE Clean Air Sub 1.0

Page 1: ...straint E Manufacturers recommended tested minimum clearances from combustible walls Tested to AS NZS 2918 2001 by APPLIED RESEARCH SERVICES LTD Clearance Rear Clearance with YUNCA STD FLUE GUARD fitted 200mm Side Clearance with YUNCA STD FLUE GUARD fitted 450mm Corner Clearance with YUNCA STD FLUE GUARD fitted 280mm F YUNCA Flue Kit Complies with AS NZS 2918 2001 Appendix F FIG A B E 1 4 2m x 150...

Page 2: ...ss than 600mm above the highest point on the roof if within 3 0m of that point or Not less than 1000mm above the intersection point with the roof and not lower than any point of the roof within 3 0m In any case the length of the flue shall not be less than 4 6m from the ash floor protector In some situations the Local Council may vary the above requirements 2 The flue system must be tested and com...

Page 3: ...UNTED SHIELD FITTED Measurements in millimetres A B E F G H 200 450 280 366 782 600 FIG D MINIMUM FLOOR PROTECTION MEASUREMENTS WITH YUNCA FLUE MOUNTED SHIELD FITTED Measurements in millimetres C D J K L M N O P 300 125 913 999 1481 1288 633 663 699 Note All Dimensions are in millimetres Above Non combustible wall clearances Brick lining From the floor to within 25mm of ceiling Leave air vents at ...

Page 4: ...E MARKING TESTED TO AS NZS 4013 C ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE WITH AS NZS 4013 D MIXING OF APPLIANCE OR FLUE SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT IN HAZARDOUS CONDITIONS WHERE SUCH ACTION IS...

Reviews: