6
WARNING!
Whenever you use extractor hoods
in combination with non electrical-
lyoperated appliances ( gas and
oil-fired appliances ) , the negative
pressure of the corresponding
room must not be more than 4 Pa
(4 * 10-5 bar).
An electrical supply of 220-240V
AC / 50 Hz is required. Do not use
a socket board or a multi socket or
an extension cord when operating
the appliance with 220–240 V/50
Hz (AC). All electrical connections
which may be damaged must be re-
paired by a qualified professional.
Only connect the appliance to a
properly grounded and dedicated
socket.
The appliance must be grounded.
Only use a proper safety socket
to minimize risk of electric shock.
The technical data of your energy
supply must meet the data on the
rating label.
Your domestic circuit must be
equipped with an automatic circuit
breaker.
Strictly observe the minimum dis-
tance between hood and hob:
1
2
3
4
5
6
8
10
11
12
13
9
Mindestabstand Unterkante Haubenkörper zu
Glaskeramik- und Gusskochplatten
65 cm
Gaskochfeld
75 cm
Kohle- / Öl- / Holzfeuerung
85 cm
Do not cook a la flambé dishes be-
low the extractor hood. The flames
may damage your appliance and/
or cause fire.
Do not operate the gas jets of a gas
hob without cookware. The flames
may damage your appliance and/
or cause fire.
If you fry, permanently keep an eye
on the oil as it can catch fire. The
risk of auto-ignition rises when
using the oil many times.
Do not carry out any procedures on
the hob using naked light or fire.
The flames may damage your ap-
pliance and/or cause fire.
The exhaust hose must not be
made of flammable materials or
contain any flammable materials.
The extracted air must not be con-
ducted by an exhaust pipe of a
heater or similar, not electrically-
operated appliances.
Operate the appliance with inser-
ted grease filters only. Otherwise
recirculatingtransported
fat will deposit in the appliance
and the exhaust system. RISK OF
7
Summary of Contents for DUANA
Page 1: ...Cod 0103089608 00 01...
Page 12: ...12 10mm 10 3x 8 x 40mm 2x 4 x 35mm...
Page 14: ...14 12 OK...
Page 15: ...15 13 3x 8x40 mm 3x 4x35 mm OK...
Page 16: ...16 14 4x 4x10 mm...
Page 23: ......
Page 26: ...26 Technical Drawing 9 A Technische Zeichnung Technical Drawing 630 320 600 205 180 930 MAX...
Page 27: ...K tech GmbH Sauerlandring 1 D 58513 L denscheid...