background image

19

Cleaning/maintenance

4

       

WARNING!

Disconnect the appliance from the 

mains before you clean or maintain it.

Ignoring the cleaning and mainte-

nance instructions will cause an 

increased risk of fire.

Clean the housing of the appliance 

with a suitable detergent. Use such a 

product carefully and economically.

Do not clean the control panel with 

a detergent. Use a damp cloth.

Otherwise you may damage the 

electronic components of the con-

trols.

Never use any alcohol-containing 

detergents to clean matt black pain-

ted appliances as these detergents 

cause colour-changes.

Clean the glass panels

4

 with a suita-

ble detergent only.

When you clean or replace the grea-

se filters or the carbon filters also 

clean all visible components on 

the bottom of the appliance with a 

mild, non- acrid and fat-dissolving 

detergent.

Do not damage the grid of metal-

made grease filters. The colour of 

the metal surface may change due 

to frequent cleaning as well as the 

use of aggressive detergents.

Such changes do not influence the 

capacity of the appliance and are 

no reason for complaint.

Do not use a steam cleaner. RISK OF 

ELECTRIC SHOCK!

Do not use any abrasive detergents.

1

2

6

4

7

8

       

NOTICE!

Take off all rings and bracelets before cleaning or maintaining the appliance; 

otherwise you will damage the surface of the appliance.

3

5

9

Aluminium filter

4.1 Grease filter

Clean the aluminium filters once a 

month by hand or in a dishwasher 

(300). Do not

use any acrid or corrosive detergents. 

Do not use any abrasive detergents! 

Do not

use any alkaline dishwasher-deter-

gents! (ph more than 7). Do not put 

the filter in

the dishwasher together with tablewa-

re Filters which are blocked with food 

debris

do not carry a guarantee. Dry the filters 

properly before you reinstall them.

4

 Equipment depends on model.

 

 

 

 

 

36 

 

  WARNING!

 

Install  the  carbon  filters  safely  and  properly;  otherwise 

the carbon filters can loosen and cause hazardous situations. 

NOTICE! 

The suction capacity is decreased by installed carbon filters. 

 

 

You can order the carbon filters at 

www.pkm-online.de 

 

 

 

 

 

 

 

 

 

 

 

3. Control panel 

 

 

Switches the light on.. 

Off. 

Low speed. 

Medium speed. 

High speed. 

 

NOTICE!

 

Never press two speed-buttons at the same time. To change 

the speed select "0" first!

 

NOTICE! 

Only switch on the lights while the appliance is operating. Do 

not switch on the lights to lighten the room.

 

 

Summary of Contents for DUANA

Page 1: ...Cod 0103089608 00 01...

Page 2: ...Safetyinstructions 4 2 Installation 9 2 1 Main components 10 2 2 Installation steps 10 3 Control panel 18 4 Cleaning maintenance 19 4 1 Grease filter 19 4 2 Carbon filters 20 4 3 Replacing of the illu...

Page 3: ...functions of the appliance shall remain reserved by the manufacturer Please dispose of the packing with respect to your current local and municipal regulations The appliance you have purchased may be...

Page 4: ...rical mains to ena ble the installation of the appliance must be performed by a qualified professional The appliance is intended for priva te use only The appliance is intended for extrac ting recircu...

Page 5: ...to your home Whenever the hood is operated to gether with chimney vented firepla ces e g coal furnace ensure there is sufficient air supply in the room where the appliance is installed in Always consu...

Page 6: ...dis tance between hood and hob 1 2 3 4 5 6 8 10 11 12 13 9 Mindestabstand Unterkante Haubenk rper zu Glaskeramik und Gusskochplatten 65 cm Gaskochfeld 75 cm Kohle l Holzfeuerung 85 cm Do not cook a la...

Page 7: ...al sensory and mental capabilities or lack of experience and knowledge if they are supervised or have been in structed concerning the safe use of the appliance and do comprehend the hazards involved C...

Page 8: ...d with a transportation lock Remove the transportation lock complete ly When removing be very careful Do not use any aggressive deter gents to remove residues of the transportation lock Clean and main...

Page 9: ...s only When the exhaust duct is connec ted horizontally a minimum falling gradient of 1 cm m or an inclination of 20 is required Otherwise con densate will get into the motor of the hood When an exhau...

Page 10: ...eisungen f r die Schrauben oder Befestigungsvorrichtungen kann zu einem Stromschlag f hren WARNUNG Besch digen Sie beim Bohren keine elektrischen Leitungen in den W nden 2 3 1 4 5 Also included chimne...

Page 11: ...IN350mm MIN350mm Ceramic glass rings hotplates 65 cm Gas cooker 75 cm Coal oil stove wood firing 85 cm 320 192 100 61 Ceramic glass rings hotplates 65 cm Gas cooker 75 cm Coal oil stove wood firing 85...

Page 12: ...12 10mm 10 3x 8 x 40mm 2x 4 x 35mm...

Page 13: ...13 11 2 x 8 2x 4x35mm 2x 8x40mm Please insert the inspection flaps to prevent contamination of the motor from the outside...

Page 14: ...14 12 OK...

Page 15: ...15 13 3x 8x40 mm 3x 4x35 mm OK...

Page 16: ...16 14 4x 4x10 mm...

Page 17: ...leitung nach au en verf gen Abluftschlauch nicht ben tigt Ansonsten sind die Installationsschrit mit den unter Installationsschritte Abluftf hrung nach au en be Abl ufen 2 Sie k nnen nur beim Umluftbe...

Page 18: ...line de 3 Control panel Switches the light on Off Low speed Medium speed High speed NOTICE Never press two speed buttons at the same time To change the speed select 0 first NOTICE Only switch on the l...

Page 19: ...issolving detergent Do not damage the grid of metal made grease filters The colour of the metal surface may change due to frequent cleaning as well as the use of aggressive detergents Such changes do...

Page 20: ...illierte Informationen vom inden Sie auf der Verpackung der Filter des Leuchtmittels UNG Trennen Sie das Ger t von der Stromversorgung f r die n chsten Schritte die Abbildung e die Aluminium Fettfilte...

Page 21: ...damper blocked motor mounting defective 1 2 remove blockage replace motor 1 2 motor not properly fixed hood not properly fixed 1 2 fix motor properly fix hood properly 1 2 INSUFFICIENT EXTRACTING CAPA...

Page 22: ...er panel Install a cover panel with moveable slats which do not obstruct the air If the hood does not work properly and or you can hear increased operating noise check the schedule below vent Check co...

Page 23: ......

Page 24: ...spose of the power cord and the plug im mediately Dispose of any paper and cardbo ard into the corresponding con tainers Dispose of any plastics into the corresponding containers If suitable container...

Page 25: ...ot influence the utility value of the product 3 damage caused by handling errors or fal se operation 4 damage caused by aggressive environ mental conditions chemicals detergents 5 damage caused by non...

Page 26: ...26 Technical Drawing 9 A Technische Zeichnung Technical Drawing 630 320 600 205 180 930 MAX...

Page 27: ...K tech GmbH Sauerlandring 1 D 58513 L denscheid...