USE OF THE REMOTE-CONTROL CONSOLE 

The Sentinel is supplied with a remote-control console. The console has three buttons: 
1) 

“ON” button (13)

 turns on/off the riflescope (fixed when pressed). 

2) 

“IR” button (14)

 - turns on/off the built-in IR Illuminator (fixed when pressed). 

3) 

“Quick start” button (15)

 - quick start-up of the riflescope and IR illuminator (the device 

works only when the button is kept pressed). After this button is released, the riflescope turns 
off, IR Illuminator and reticle go out, but tube's residual green glow remains for some time 
afterwards. 

 
 
 
 
 
 
 
 
 
 

 
INSPECTION 

It is recommended to inspect the SENTINEL before each use for: 

 

Body condition; cracks, deep dents and corrosion are not acceptable.  

 

Check that the scope is firmly attached to the rifle.  

 

Objective lens, eyepiece and IR illuminator condition; cracks, finger marks, dirt, water 
drops and other stains are not acceptable.  

 

Make sure not to use depleted batteries or batteries that show stains of electrolyte, salt or 
acid leaks; these conditions may result in damage to the scope. 

 

Check that the power switches (3) and the reticle brightness knob (4) are functioning 
normally.  

 

Check that the objective lens ring (6) and the eyepiece ring (7) are movable.   

 

MAINTENANCE 

It is recommended that technical maintenance should be performed on the SENTINEL at least 
2 times a year; tasks for technical maintenance include: 
To clean the exterior of the scope of dust, dirt and moisture using a dry tissue with a few drops 
of gun oil or similar substance applied.  
To clean the electrical contact lead located in the battery housing using pure alcohol.  
To examine the lenses of the eyepiece, objective lens and IR illuminator and blow off sizable 
particles of sand and dust; clean the lenses only if necessary.  
Do not pour liquids directly onto the lens surface when cleaning; apply solution to a clean, dry 
cloth and then proceed to clean the lens.  
 
Warning: Please use extreme caution when handling hazardous substances, such as alcohol. 
 

THE SENTINEL MAGNIFIER LENS 2.5x50 

The NVRS magnifier lens attachment accessory (#29091) helps increase magnification of the 
SENTINEL with an objective lens diameter of 50mm up to 1.75 times. Screw the magnifier lens 
onto the objective lens of the scope according to the instruction manual for the “NVRS 2.5x50 
Doubler”. Sight in the scope after the magnifier lens is attached due to movement of the reticle. 
 

ADDITIONAL WEAVER MIL-STD-1913 RAILS 

The SENTINEL has an additional Weaver rail (12) on the left side of the body. With the help of 
this mount it is possible to install: 

Summary of Contents for SENTINEL 26015T

Page 1: ...rating against water intrusion Precision internal windage elevation adjustment Ergonomic design Quick power up Vertical positioning of the battery ensures uninterrupted power supply when shooting Remo...

Page 2: ...ufacturer s warranty will be voided if damage is caused by caliber cartridges greater than 7 62 300 hand made cartridges or shooting from a smooth bore barrel Do not remove the lens cap in a lit area...

Page 3: ...ob of the cover 90 clockwise OPERATING THE SENTINEL Warning It is strongly recommended to test and operate the SENTINEL in dark conditions or at night time Install the batteries according to the direc...

Page 4: ...y following the instruction in section SIGHTING OF THE SENTINEL Note The SENTINEL and its IR can be activated using the remote control SIGHTING IN THE SENTINEL Warning Be sure to follow proper safety...

Page 5: ...get is 50 meters 55 yards away If the same target fits between the marks located just beneath the horizontal line of the reticle the target is 100 meters 110 yards away If the same target fits between...

Page 6: ...epiece ring 7 are movable MAINTENANCE It is recommended that technical maintenance should be performed on the SENTINEL at least 2 times a year tasks for technical maintenance include To clean the exte...

Page 7: ...partment due to leaky batteries or contact points becoming exposed to a chemically reactive solution Clean the battery compartment focusing on the contact points The red reticle is blurred and can not...

Page 8: ...g The scope is not mounted securely Check that the scope is firmly attached to the mount and make sure that the same type and caliber bullets are being used as when the scope was initially sighted in...

Reviews: