Installation
SMOKE BAFFLES
The smoke baffles are factory installed. They
must be checked to see that they have not
become dislodged during shipping. See Fig. 14-A.
Complete the following steps to check the baffles:
1. Hold the baffle in proper position. Tilt the rear up to
clear baffle mounting brackets.
2. Push baffle up to top of combustion chamber above
all three brackets, level off, slide left and lower onto
mounting brackets.
3. Check to see that all three brackets are engaged.
4. Repeat with second baffle, making sure baffles
interlock as shown. See Fig 14-B. When properly
installed, baffles will not move more than 1/4" in any
direction.
NOTE: Failure to have baffles properly installed
will severely reduce combustion efficiency.
Questions? Visit www.yukon-eagle.com or call 1-800-358-0060
FIG. 14-B
FIG. 14-A
17
Summary of Contents for Oil Furnace
Page 7: ...7 Furnace Features Eagle I Husky v w x y z u...
Page 9: ...9 Furnace Features Eagle II Polar v w y z x u...
Page 28: ...28 Installation Questions Visit www yukon eagle com or call 1 800 358 0060...
Page 38: ...38 OIL AND WOOD HEATING WITH A C Wiring Diagrams...
Page 39: ...39 GAS AND WOOD HEATING ONLY Wiring Diagrams...
Page 40: ...GAS AND WOOD HEATING WITH A C 40 Wiring Diagrams...
Page 52: ...52 Exploded Views Parts List EAGLE I HUSKY MODELS LWO 112 LWG 112...
Page 54: ...54 Exploded Views Parts List EAGLE II POLAR MODELS LWO 168 LWG 168...
Page 58: ...58 Exploded Views Parts List WAYNE MODEL P250AF DIN GAS BURNER...