EM-1359
- 9 -
ELDFG-03EH-*-*-XY-*-*-10
*1. For NULL adjustment, remove the protective screw and turn the trimmer behind the screw.
After adjustment, be sure to attach the protective screw.
*2. The 6 + PE connector is not included with the valve. Prepare it separately.
YUKEN parts number: TK290457-1
*3. With standard sub-plates, one (“T
A
”) of the two tank ports is used, but either one may be used.
●
Dimensions of Mounting Surface
Prepare the mounting surface as shown below. Basically, the dimensions of the mounting
surface conform to ISO 4401-05-04-0-94. The mounting surface should have a good
machined finish, e.g. surface roughness of 6-S.
Indicator Lamp
Cylinder Port “A” Pressure Port “P“ Cylinder Port “B“
M5 (+) Thd.
Tank Port “T
A
”
7 Dia. Through
Air Vent
3 Hex. Soc.
Indicator Lamp
Color
Green
Red
Power Supply
Deviation Alarm
Cable Applicable:
Outside Dia. 8 - 10 mm
6 + PE Connector
*2
Nameplate
Mounting Surface
(O-Rings Furnished)
●
Protective Screw for NULL Adjuster Hole
*1
Tank Port “T
B
”
4 Places
11 Dia.
4 Places
M6 Thd. 13 Deep
●
O-Rings for the Ports
AS568-014 (NBR, Hs90): 5 Pieces
11 C’ Bore 4 Places