I. Model Order Code 

The type of AI-218 is made up of 4 parts

,

 for example,   

AI-218 

A1 

L2 

Part 1 (Series) 

Part 2 (Size) 

Part 3 (Oupt) 

Part 4 (AUX) 

 

1.  (Part 1) Model Series 

AI-218, standard temperature controller , 0.3%FS±1

 accuracy. 

Multiple thermocouples and RTDs are selectable 

Maximum support two alarms contact output 

Universal supply power 100~240VAC, 50Hz/60Hz 

 

2.  (Part 2) Front panel dimension   

Panel Size 

Front Panel 

width×height

 

Cut Out 

width×height

 

Depth Behind Mounting Surface 

A1 

96×96mm 

92×92mm 

70mm 

B1 

160×80mm 

152×76mm 

70mm 

D1 

72×72mm 

68×68mm 

78.5mm 

E1 

48×96mm vertical 

45×92mm 

70mm 

F1 

96×48mm horizontal 

92×45mm 

70mm 

D1 

48×48mm 

45×45mm 

78.5mm 

96×96mm 

92×92mm 

100mm 

160×80mm 

152×76mm 

100mm 

72×72mm 

68×68mm 

95mm 

D2 

48×48mm 

45×45mm 

95mm 

48×96mm 

45×92mm 

100mm 

96×48mm 

92×45mm 

100mm 

Summary of Contents for AI-218

Page 1: ...Automation Technology Co Ltd Website http www yudian us http www yudian com hk Email sales yudian com hk Tel 852 2770 8785 Fax 852 2770 8796 ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER AI 218 Opera...

Page 2: ...Multiple thermocouples and RTDs are selectable Maximum support two alarms contact output Universal supply power 100 240VAC 50Hz 60Hz 2 Part 2 Front panel dimension Panel Size Front Panel width height...

Page 3: ...tput L5 Dual relay output module Output module Capacity 2A 250VAC normal open support AU1 and AU2 alarm output G SSR voltage output module 30mA 5VDC D1 sized controller is fixed to relay output L or S...

Page 4: ...s The instrument will also jumps out auomatically from the parameter table if no key is pressed in 30 seconds Setting Loc 808 and then press will access System Parameter Table See V PARAMETER AND SETT...

Page 5: ...o 808 and press to unlock the System Parameter Table 0 255 0 System Parameter Table Loc 808 to unlock AHYS Alarm Hysteresis Avoid frequent alarm on off action because of the fluctuation of PV AHY 2 by...

Page 6: ...ction in ON OFF control mode PV SV Output turns OFF Relay opens PV SV CHY Output turns ON Relay closes 0 200 InP Input specification Thermocouples RTD 0 K 1 S 2 R 4 E 5 J 7 N 21 Pt100 0 21 0 dPt Resol...

Page 7: ...nel dimension B B1 F F1 please rotate the diagram clockwise by 90 degree Panel dimension D 72 x 72mm Panel dimension D1 D2 48 x 48mm Remarks 1 Thermocouples compensate wires should be directly screwed...

Reviews: