YTL DDS-1Y User Manual Download Page 7

6

8.

8.

8.

8.

Safety

Safety

Safety

Safety Instructions

Instructions

Instructions

Instructions

Information

Information

Information

Information for

for

for

for Your

Your

Your

Your Own

Own

Own

Own Safety

Safety

Safety

Safety

This manual does not contain all of the safety measures for operation of this equipment (module,

device) because special operating conditions, local code requirements or local regulations may

necessitate further measures. However, it does contain information which must be adhered to for

your own personal safety and to avoid damage to the equipment. This information is highlighted

by a warning triangle with an exclamation mark or a lightning bolt depending on the severity of the

warning.

Warning

Warning

Warning

Warning

Means that failure to observe the instruction can result in death, serious injury or considerable

material damage.

Caution

Caution

Caution

Caution

Means hazard of electric shock and failure to take the necessary safety precautions will result in

death, serious injury or considerable material damage.

Qualified

Qualified

Qualified

Qualified personnel

personnel

personnel

personnel

Installation and operation of this equipment described in this manual may only be performed by

qualified personal.

Only people that are authorized to install, connect and use this equipment and have the proper

knowledge about labeling and grounding electrical equipment and circuits and can do so

according to safety and regulatory standards are considered qualified personnel in the manual.

Use

Use

Use

Use for

for

for

for the

the

the

the intend

intend

intend

intend purpose

purpose

purpose

purpose

The equipment (device, module) may only be used for the application cases specified in the

catalog and the user manual and only in connection with devices and components recommended

and approved by YTL.

Exclusion

Exclusion

Exclusion

Exclusion of

of

of

of liability

liability

liability

liability

We have checked the contents of this publication and every effort has been made to ensure that

the descriptions are as accurate as possible. However, deviations from the description cannot be

completely ruled out, so that no liability can be accepted for any errors or omissions in the

information given. The data in this manual is checked regularly and the necessary corrections will

be included in subsequent editions. If you have any suggestions, pls let us know.

Summary of Contents for DDS-1Y

Page 1: ......

Page 2: ...2kg and 76mm Width 2 2 2 2 Technical Technical Technical Technical Parameters Parameters Parameters Parameters Voltage 230V Current 10 100 A Accuracy class 1 0 Standard IEC62052 11 IEC62053 21 Frequency 50 60Hz Impulse constant 1600imp kWh Display Counter 5 1 Power consumption 8VA 0 4W Starting current 0 004Ib Working Temperature 25 70 Storage Temperature 40 80 Average humidity value of year 75 Ma...

Page 3: ...y flame resistant ABS Base Bottom Grey flame resistant ABS 4 4 4 4 Connection Connection Connection Connection Diagram Diagram Diagram Diagram 5 5 5 5 Meter Meter Meter Meter Dimensions Dimensions Dimensions Dimensions 76mm 100 mm 6 mm 5 4 5mm 36 m m Height 100mm Width 76mm Depth 65mm Weight 0 3092kg Net ...

Page 4: ...ation Installation Instruction Instruction Instruction Instruction Choose 35mm standard Din Rail the length is confirmed by yourself fixed them in the location which are waiting for installation Put the meter into the upper Din Rail then push down the clip in the meter bottom see Fig 1 After the bottom of the meter install into the Din Rail successfully release the clip to make sure the meter have...

Page 5: ...2 2 Fig Fig Fig Fig 3 3 3 3 Fig 4 is after installation Fig Fig Fig Fig 4 4 4 4 Fig Fig Fig Fig 5 5 5 5 Making the connection according to the wiring diagram After connection use lead sealing to seal terminal cover see Fig 5 ...

Page 6: ...25 30 23 1 2 24 4 42 33 40 30 1 2 73 6 55 42 50 40 7 1 33 10 80 55 75 55 7 1 76 16 105 80 100 75 7 2 12 25 140 105 130 100 7 2 50 35 170 140 160 125 19 1 83 50 225 170 205 150 19 2 14 75 280 225 255 185 19 2 50 95 340 280 320 240 Note BX BLX copper aluminum core rubber insulated wire or BV BLV copper aluminum core PVC plastic insulated wire widely used in 500V or less than 500V AC and DC power dis...

Page 7: ...el personnel personnel personnel Installation and operation of this equipment described in this manual may only be performed by qualified personal Only people that are authorized to install connect and use this equipment and have the proper knowledge about labeling and grounding electrical equipment and circuits and can do so according to safety and regulatory standards are considered qualified pe...

Page 8: ...ke sure the integrity of the unit If in doubt don t use the equipment and contact technical staff Mounting of electric appliances must be carried out only by skilled electricians It is imperative to observe the generally applicable safety measures In case of failure and or malfunctioning of the device turn off it For any repair only contact technical staff Failure to comply with the above may comp...

Reviews: