OT2115
Driver
11
4.6 Electrical connection
OT series actuator external electrical wiring diagram as shown in Figure 3-6, annex
see table 3-1.
Legend
:
Cable
Shielding layer of cable
The stranded conductor
Ground wire connection on controller case
Figure 3-6 electrical wiring diagram
technical requirement:
1. Actuator power cable W1 and actuator drive cable W2 are used in 8, 6 or 4 wire.
From the power to the drive, and then from the drive to the actuator, during which
the total length of the cable must not exceed the maximum value shown in the
following formula:
If using 4 wires, the formula is: 1/2 battery cable actuator cable length
is less than or equal to 12.2m;
If the use of 6 wire: the total length of the actuator cable is multiplied by 1.6,
that is: 19.52m;
If the use of 8 wire: the total length of the actuator cable is multiplied by 2.5,
that is: 30.50m.
Connector plug
Model
J1
’
YA3106F20-8SW
J2
’、
J3
’
YA3106F20-8SN
J3
J2