background image

1

2

1

2

3

5

8

9

4

7

6

12

10

11

13

Wireless 5­in­1 Sensor

1.   Rain collector                      2.   Balance indicator              3.   Antenna
4.   Wind cups                           5.   Mounting pole                   6.   Radiation shield
7.   Wind vane                           8.   Mounting base                  9.   Mounting claim
10. Red LED indicator              11.  RESET button                 12.  Battery door
13. Screws

Rain gauge

1.  Rain collector
2.  Tipping bucket
3.  Drain holes 
4.  Rain sensor

Temperature and humidity sensor

1.  Radiation shield
2.  Sensor casing (Temperature and humidity sensor)

2

Summary of Contents for YC9385

Page 1: ...PROFESSIONAL WEATHER STATION WITH WIRELESS 5 IN 1 SENSOR Model YC9385 USERS INSTRUCTION...

Page 2: ...he warranty Placement of this product on certain types of wood may result in damage to its nishing for which manufacture will not be responsible Consult the furniture manufacturer s care instructions...

Page 3: ...vided to the corresponding maximum and minimum records for each weather details The system also analyzes the records for your convenient viewing such as the display of rainfall in terms of rain rate d...

Page 4: ...5 Mounting pole 6 Radiation shield 7 Wind vane 8 Mounting base 9 Mounting claim 10 Red LED indicator 11 RESET button 12 Battery door 13 Screws Rain gauge 1 Rain collector 2 Tipping bucket 3 Drain hole...

Page 5: ...C Signal strength indicator 6 DST icon 7 Moon phase 8 Day of the week 9 Alarm icon 10 Date 11 Month Indoor temperature and humidity window 1 Comfort cold hot icon 2 Indoor indicator 3 Indoor humidity...

Page 6: ...ds indicator 4 Histogram 5 Hi Alert and Alarm 6 Current rainfall rate 7 Rainfall unit in mm Wind direction Wind speed 1 Wind direction indicator 2 Wind direction indicator s during last hour 3 Current...

Page 7: ...partment on tightly Note Ensure the water tight O ring is properly aligned in place to ensure water resistant The red LED will begin ashing every 12 seconds ASSEMBLY THE STAND AND POLE Step 1 Insert t...

Page 8: ...e wind direction vane Secure the mounting stand and bracket included to a post or pole and allow minimum 1 5m o the ground Mounting guidelines 1 Install the wireless 5 in 1 sensor at least 1 5m o the...

Page 9: ...Main Unit will automatically search and connect the wireless 5 in 1 sensor antenna blinking Once the connection is successful antenna mark and readings for outdoor temperature humidity wind speed win...

Page 10: ...matically switch when the daylight saving time is in e ect User can set the DST to OFF to disable the feature To one time Stop Activate RCC signal reception 1 During the RCC reception press RCC button...

Page 11: ...set relative atmospheric pressure value 1 Get the atmospheric pressure data of the sea level it is also the relative atmospheric pressure data of your home area through the local weather service inter...

Page 12: ...utes at every hour on the hour and at 6 12 18 24 30 36 42 48 54 minute past the hour To select the measurement unit for the rainfall 1 Press and hold RAINFALL button 2 seconds to enter unit setting mo...

Page 13: ...Dust and loose paper raised Small branches begin to move Branches of a moderate size move Small trees in leaf begin to sway Large branches in motion Whistling heard in overhead wires Umbrella use beco...

Page 14: ...d dew when it forms on a solid surface The dewpoint temperature is calculated from the indoor temperature and humidity measured at the Main Unit HISTORY DATA ALL RECORDS IN THE PAST 24 HOURS The Displ...

Page 15: ...e ALERT button until the desired area is selected 2 Use UP DOWN buttons to adjust the setting 3 Press ALERT button to con rm and continue to next setting To enable disable the HI LO alert 1 Press ALER...

Page 16: ...sensor the sensors were likely to be triggered resulting in erroneous rainfall and wind measurements After the installation user may clear out all the erroneous data from the Display Main Unit without...

Page 17: ...es from left to right Below are the 2 tables which illustrate how the moon will appear on the main unit Northern hemisphere Southern hemisphere MAINTENANCE To clean the rain collector 1 Rotate the rai...

Page 18: ...ation shield 2 Check the sensor casing 1 Check the drain hole in the rain collector 2 Check the balance indicator 1 Check wind cups Anemometer 2 Check the wind vane 1 Relocate the main unit and 5 in 1...

Page 19: ...C 525 825 mmHg 3mmHg 0 50 C 15 95 20 66inHg 0 24inHg 32 122 F 20 67 32 48inHg 0 12inHg 32 122 F Resolution 1hPa 0 01inHg 0 1mmHg W eather forecast Sunny Clear slightly Cloudy Cloudy Rainy Rainy Storm...

Page 20: ...lert WIND SPEED Displayed range 1 to 99 1 LO 99 HI Operating range 1 to 99 Resolution 1 Accuracy 3 typical 25 C 77 F Display modes Display modes Current Min and Max Historical data for past 24 hours C...

Page 21: ...19 SENSOR AND MAIN UNIT STAND INSTALLATION...

Page 22: ...ice youshiko co UKCA Declaration of Conformity Made for Youshiko in PRC Y oushiko Ltd hereby declares that the product fully complied to applicable guidelines and corresponding standards for sales in...

Reviews: