3 cores need to made by builder:
Magnetic inductance L1: please use yellow enamel insulated wire, about 15cm, make 9 turns.
Magnetic inductance L2: please use red enamel insulated wire, about 15cm, make 7 turns. As above.
T1 transformer is 8:2, please use red enamel insulated wire, about 15cm, make 8 turns as primary. Use
yellow enamel insulated wire, about 6cm, make 2 turns as secondary. Connect primary to the 2 pads
connected to C7 and Q8, secondary to the pad connected to R28 and ground. As below.