background image

1 - 4

You may have a series of custom settings and want to correct a single setting.  To do so, just scan the new setting to overwrite 
the old one.  For example, if you had previously saved the setting for Beeper Volume at Low to your custom defaults, and decide 
you want the beeper volume set to High, just scan the 

Set Custom Defaults

 bar code, then scan the Beeper Volume High 

menu code, and then 

Save Custom Defaults

.  The rest of the custom defaults will remain, but the beeper volume setting will be 

updated.

Resetting the Custom Defaults

If you want the custom default settings restored to your scanner, scan the 

Activate Custom Defaults

 bar code below.  This is 

the recommended default bar code for most users.  It resets the scanner to the custom default settings.  If there are no custom 
defaults, it will reset the scanner to the factory default settings.  Any settings that have not been specified through the custom 
defaults will be defaulted to the factory default settings.

Activate Custom Defaults

Summary of Contents for YJ-HF500

Page 1: ...YJ HF500 Area Imaging Scanner User s Guide...

Page 2: ...for the selection and use of software and or hardware to achieve intended results This document contains proprietary information that is protected by copyright All rights are reserved No part of this...

Page 3: ...l Default Settings 2 3 Bioptic Aux Port Configuration 2 3 Datalogic Magellan Bioptic Aux Port Configuration 2 3 NCR Bioptic Aux Port Configuration 2 4 Wincor Nixdorf Terminal Default Settings 2 4 Winc...

Page 4: ...ing 3 6 Poor Quality Codes 3 7 Poor Quality PDF Codes 3 7 Mobile Phone Read Mode 3 7 Reread Delay 3 8 User Specified Reread Delay 3 8 2D Reread Delay 3 8 Character Activation Mode 3 9 Activation Chara...

Page 5: ...ts 5 9 Chapter 6 Symbologies All Symbologies 6 1 Message Length Description 6 1 Codabar 6 2 Codabar Concatenation 6 3 Code 39 6 4 Code 32 Pharmaceutical PARAF 6 5 Full ASCII 6 6 Code 39 Code Page 6 6...

Page 6: ...ode 6 40 Postal Codes 2D 6 41 Single 2D Postal Codes 6 41 Combination 2D Postal Codes 6 42 Postal Codes Linear 6 45 China Post Hong Kong 2 of 5 6 45 Korea Post 6 46 Chapter 7 Interface Keys Keyboard F...

Page 7: ...11 1 Maintenance 11 1 Cleaning the Device 11 1 Inspecting Cords and Connectors 11 1 Replacing Cable in the Scanner 11 1 Troubleshooting the Scanner 11 1 Chapter 12 Technical Assistance Appendix A Ref...

Page 8: ...vi...

Page 9: ...en the shipping carton containing the product take the following steps Check for damage during shipment Report damage immediately to the carrier who delivered the carton Make sure the items in the car...

Page 10: ...able for your type of terminal computer Note The power supply must be ordered separately if needed 3 Plug the serial connector into the serial port on your computer Tighten the two screws to secure th...

Page 11: ...it may be necessary to tilt the code up 15 to 18 to prevent unwanted reflection Menu Bar Code Security Settings Youjie scanners are programmed by scanning menu bar codes or by sending serial commands...

Page 12: ...Custom Defaults The rest of the custom defaults will remain but the beeper volume setting will be updated Resetting the Custom Defaults If you want the custom default settings restored to your scanner...

Page 13: ...ine feed LF suffix baud rate and data format as indicated below USB IBM SurePos Scan one of the following Plug and Play codes to program the scanner for an IBM SurePos USB handheld scanner or IBM Sure...

Page 14: ...o emulate a regular RS232 based COM Port If you are using a Microsoft Windows PC you will need to download a driver from the Youjie website www youjieaidc com The driver will use the next available CO...

Page 15: ...and programs the follow ing prefixes for each symbology Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for a Youjie bioptic scanner auxiliary port configu...

Page 16: ...nner for a Wincor Nixdorf Beetle terminal This bar code sets the baud rate to 115200 bps and the data format to 8 data bits no parity 1 stop bit The following prefixes are programmed for each symbolog...

Page 17: ...ayout refer to the chart below for your keyboard country Scan the appropriate bar code below to change the layout By default national character replacements are used for the following characters See I...

Page 18: ...2 6 Keyboard Countries Continued Belgium Bosnia Brazil Brazil MS Bulgaria Cyrillic Bulgaria Latin Canada French legacy Canada French Canada Multilingual Croatia Czech...

Page 19: ...2 7 Keyboard Countries Continued Czech Programmers Czech QWERTY Czech QWERTZ Denmark Dutch Netherlands Estonia Faroese Finland France Gaelic Germany...

Page 20: ...2 8 Keyboard Countries Continued Greek Greek 220 Latin Greek 220 Greek 319 Latin Greek 319 Greek Latin Greek MS Greek Polytonic Hebrew Hungarian 101 key Hungary...

Page 21: ...2 9 Keyboard Countries Continued Iceland Irish Italian 142 Italy Japan ASCII Kazakh Kyrgyz Cyrillic Latin America Latvia Latvia QWERTY Lithuania...

Page 22: ...2 10 Keyboard Countries Continued Lithuania IBM Macedonia Malta Mongolian Cyrillic Norway Poland Polish 214 Polish Programmers Portugal Romania Russia...

Page 23: ...2 11 Keyboard Countries Continued Russian MS Russian Typewriter SCS Serbia Cyrillic Serbia Latin Slovakia Slovakia QWERTY Slovakia QWERTZ Slovenia Spain Spanish variation...

Page 24: ...12 Keyboard Countries Continued Sweden Switzerland French Switzerland German Tatar Turkey F Turkey Q Ukrainian United Kingdom United States Dvorak United States Dvorak left United Stated Dvorak right...

Page 25: ...Lock is used if you change the Caps Lock key on and off The software tracks and reflects if you have Caps Lock on or off This selection can only be used with systems that have an LED that notes the Ca...

Page 26: ...yle selections Default Keyboard Conversion Off Control Character Output This selection sends a text string instead of a control character For example when the control character for a carriage return i...

Page 27: ...Suffix Off The scanner sends key combinations for ASCII control characters for values 00 1F but it does not translate any prefix or suffix information Default Control ASCII Mode Off Turbo Mode The sca...

Page 28: ...ping characters Default Off RS232 Modifiers RS232 Baud Rate Baud Rate sends the data from the scanner to the terminal at the specified rate The host terminal must be set for the same baud rate as the...

Page 29: ...elect 7 data bits For applications that require use of the full ASCII set select 8 data bits per character Default 8 Stop Bits sets the stop bits at 1 or 2 Default 1 Parity provides a means of checkin...

Page 30: ...ware commands from the host device When RTS CTS is turned Off no data flow control is used Flow Control No Timeout The scanner asserts RTS when it has data to send and will wait indefinitely for CTS t...

Page 31: ...the scanner data transmission stops To resume transmission the host sends the XON character DC1 hex 11 Data transmission continues where it left off when XOFF was sent Default XON XOFF Off ACK NAK Aft...

Page 32: ...scanner Default Packet Mode Off Scanner Bioptic ACK NAK Mode Bioptic ACK Nak On must be scanned so the scanner will wait for an ACK or NAK from a bioptic scanner after each packet is sent The Scanner...

Page 33: ...BEL On bar code below the scanner will beep every time a BEL character is received from the host Default Beep on BEL Off Good Read and Error Indicators Beeper Good Read The beeper may be programmed On...

Page 34: ...ead The beeper pitch codes modify the pitch frequency of the beep the scanner emits on a good read Default Medium Beeper Pitch Error The beeper pitch codes modify the pitch frequency of the sound the...

Page 35: ...n sync with one another To change the number of beeps scan the bar code below and then scan a digit 1 9 bar code and the Save bar code on the Programming Chart inside the back cover of this manual Def...

Page 36: ...canner then the LED brightens to read the code If the light level in the room is not high enough Presentation Mode may not work properly Scan the following bar code to program your scanner for Present...

Page 37: ...ed to it If the scanner has difficulty waking up to read bar codes you may need to set the Idle Illumination to a brighter setting Presentation Sensitivity Presentation Sensitivity is a numeric range...

Page 38: ...Right of Presentation Centering Window bar codes In the example below the white box is the centering window The centering window has been set to 20 left 30 right 8 top and 25 bottom Since Bar Code 1...

Page 39: ...ading Default Poor Quality PDF Reading Off Mobile Phone Read Mode When this mode is selected your scanner is optimized to read bar codes from mobile phone or other LED displays However the speed of sc...

Page 40: ...want to set your own length for the reread delay scan the bar code below then set the delay from 0 30 000 milliseconds by scanning digits from the inside back cover then scanning Save 2D Reread Delay...

Page 41: ...ion Chart Code Page 1252 page A 3 find the hex value that represents the character you want to use to trigger scanning Scan the following bar code then use the Programming Chart to read the alphanumer...

Page 42: ...character you will send from the host to terminate scanning Default Off Deactivation Character This sets the character used to terminate scanning when using Character Deactivation Mode On the ASCII Co...

Page 43: ...l not be decoded or output by the scanner If centering is turned on by scanning Centering On the scanner only reads codes that pass through the centering window you specify using the Top of Centering...

Page 44: ...bar code below is an example of this type of bar code Scan Video Reverse Only to read only inverted bar codes Scan Video Reverse and Stan dard Bar Codes to read both types of codes Note After scanning...

Page 45: ...upside down Use the working orientation settings if your direction sensitive codes will not usually be presented upright to the scanner Default Upright Video Reverse Off Upright Vertical Top to Botto...

Page 46: ...3 14...

Page 47: ...bologies the specific symbology ID value counts as an added prefix or suffix character The maximum size of a prefix or suffix configuration is 200 characters which includes header information To Add a...

Page 48: ...character from a symbology When you Clear All Prefixes Suffixes all the prefixes or suffixes for a symbology are deleted Step 1 Scan the Clear One Prefix or Clear One Suffix symbol Step 2 Determine t...

Page 49: ...the Intercharacter Delay bar code below then scan the number of 5ms delays and the Save bar code using the Programming Chart inside the back cover of this manual To remove this delay scan the Intercha...

Page 50: ...al To remove this delay scan the Interfunction Delay bar code then set the number of delays to 0 Scan the Save bar code using the Programming Chart inside the back cover of this manual Intermessage De...

Page 51: ...have changed data format settings and wish to clear all formats and return to the factory defaults scan the Default Data Format code below Add a Data Format Step 1 Scan the Enter Data Format symbol pa...

Page 52: ...t for one symbology If you are clearing the primary format scan 0 from the Programming Chart inside the back cover of this manual If you are clearing an alternate format scan 1 2 or 3 depending on the...

Page 53: ...Chart Code Page 1252 beginning on page A 3 for decimal hex and character codes F2 Example Send a number of characters Send the first 10 characters from the bar code above followed by a carriage return...

Page 54: ...input message character included Syntax E9nn where nn stands for the numeric value 00 99 for the number of characters that will not be sent at the end of the message Insert a character multiple times...

Page 55: ...nd 6 characters followed by a carriage return Using the bar code above Command string FE31F7F2060D FE is the Compare characters command 31 is the hex value for 1 F7 is the Move the cursor to the begin...

Page 56: ...ds all the data after followed by a carriage return Using the bar code above Command string E630F10D E6 is the Search forward for a non matching character command 30 is the hex value for 0 F1 is the S...

Page 57: ...he zeroes in the bar code above with carriage returns Command string E402300DF10D E4 is the Replace characters command 02 is the total count of characters to be replaced plus the replacement character...

Page 58: ...the Send all characters command 0D is the hex value for a CR If this bar code is read the next data format if there is one will be used on this data If there is no other format the format fails and th...

Page 59: ...lt Data Formatter On Not Required Keep Prefix Suffix Primary Alternate Data Formats You can save up to four data formats and switch between these formats Your primary data format is saved under 0 Your...

Page 60: ...5 10...

Page 61: ...o set the same value for mini mum and maximum length to force the scanner to read fixed length bar code data This helps reduce the chances of a misread EXAMPLE Decode only those bar codes with a count...

Page 62: ...r transmit or not transmit Start Stop characters Default Don t Transmit Codabar Check Character Codabar check characters are created using different modulos You can program the scanner to read only Co...

Page 63: ...scanner from decoding a single D Codabar symbol without its companion This selection has no effect on Codabar symbols without Stop Start D characters Codabar Message Length Scan the bar codes below to...

Page 64: ...data with or without a check character When Check Character is set to Validate but Don t Transmit the unit only reads Code 39 bar codes printed with a check character but will not transmit the check c...

Page 65: ...fore transmitting them to the host computer When the scanner encounters a Code 39 bar code with the append trigger character s it buffers Code 39 bar codes until it reads a Code 39 bar code that does...

Page 66: ...f this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements on page A 7 and scan the value and the Save bar code f...

Page 67: ...ck digit with the scanned data When Check Digit is set to Validate and Transmit the scanner only reads Interleaved 2 of 5 bar codes printed with a check digit and will transmit this digit at the end o...

Page 68: ...nsmit the unit only reads NEC 2 of 5 bar codes printed with a check digit but will not transmit the check digit with the scanned data When Check Digit is set to Validate and Transmit the scanner only...

Page 69: ...efault 4 Maximum Default 80 Code 93 Default All Code 93 Settings Code 93 On Off Code 93 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6...

Page 70: ...de 93 bar code that starts with a character other than a space Default Off Code 93 Code Page Code pages define the mapping of character codes to characters If the data received does not display with t...

Page 71: ...f 5 Industrial On Off Straight 2 of 5 Industrial Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 1 for additional information Minimum an...

Page 72: ...5 IATA On Off Straight 2 of 5 IATA Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 1 for additional information Minimum and Maximum len...

Page 73: ...atrix 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 1 for additional information Minimum and Maximum lengths 1 80 Minimum Defau...

Page 74: ...e 11 bar codes Default Two Check Digits Code 11 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 1 for additional information Minimum and...

Page 75: ...ent recommendation to use Code 128 due to its high degree of security and its space efficient design 3 a variation of Code 128 that supports concatenation of neigh boring symbols and 4 the standard la...

Page 76: ...t On Code 128 Code Page Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the bar code being scanned was...

Page 77: ...h Refer to Message Length Description page 6 1 for additional information Minimum and Maximum lengths 1 80 Minimum Default 1 Maximum Default 80 UPC A Default All UPC A Settings UPC A On Off Note To co...

Page 78: ...system digit of a U P C symbol is normally transmitted at the beginning of the scanned data but the unit can be programmed so it will not transmit it Default On UPC A Addenda This selection adds 2 or...

Page 79: ...e UPC A and EAN 13 with Extended Coupon Code When left on the default setting Off the scanner treats Coupon Codes and Extended Coupon Codes as single bar codes If you scan the Allow Concatenation code...

Page 80: ...DataBar code data Default GS1 Out put Off UPC E0 Default All UPC E Settings UPC E0 On Off Most U P C bar codes lead with the 0 number system To read these codes use the UPC E0 On selection If you need...

Page 81: ...m the bar code and the data from the addenda When turned Off there is no space Default On UPC E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scann...

Page 82: ...it and 5 Digit Addenda UPC E1 Most U P C bar codes lead with the 0 number system For these codes use UPC E0 page 6 20 If you need to read codes that lead with the 1 number system use the UPC E1 On sel...

Page 83: ...converted to 13 digit EAN 13 codes by adding a zero to the front When Do not Convert UPC A is selected UPC A codes are read as UPC A EAN JAN 13 Check Digit This selection allows you to specify whethe...

Page 84: ...at have addenda Default Not Required EAN JAN 13 Addenda Separator When this feature is On there is a space between the data from the bar code and the data from the addenda When turned Off there is no...

Page 85: ...their equivalent ISBN number format Default Off EAN JAN 8 Default All EAN JAN 8 Settings EAN JAN 8 On Off EAN JAN 8 Check Digit This selection allows you to specify whether the check digit should be...

Page 86: ...ed is scanned the scanner will only read EAN JAN 8 bar codes that have addenda Default Not Required EAN JAN 8 Addenda Separator When this feature is On there is a space between the data from the bar c...

Page 87: ...inted with the specified type check character s and will transmit the character s at the end of the scanned data When Check Character is set to Validate Type 10 11 but Don t Transmit the unit will onl...

Page 88: ...gth Refer to Message Length Description page 6 1 for additional information Minimum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 Validate Type 11 then Type 10 Character and Transmit D...

Page 89: ...DataBar Omnidirectional Default All GS1 DataBar Omnidirectional Settings GS1 DataBar Omnidirectional On Off GS1 DataBar Limited Default All GS1 DataBar Limited Settings GS1 DataBar Limited On Off On O...

Page 90: ...ength Scan the bar codes below to change the message length Refer to Message Length Description page 6 1 for additional information Minimum and Maximum lengths 4 74 Minimum Default 4 Maximum Default 7...

Page 91: ...Maximum Default 600 Codablock F Default All Codablock F Settings Codablock F On Off Codablock F Message Length Scan the bar codes below to change the message length Refer to Message Length Description...

Page 92: ...l information Minimum and Maximum lengths 1 2750 Minimum Default 1 Maximum Default 2750 MacroPDF417 MacroPDF417 is an implementation of PDF417 capable of encoding very large amounts of data into multi...

Page 93: ...6 1 for additional information Minimum and Maximum lengths 1 366 Minimum Default 1 Maximum Default 366 GS1 Composite Codes Linear codes are combined with a unique 2D composite component to form a new...

Page 94: ...clude UPC A and UPC E EAN 13 and EAN 8 ITF 14 GS1 128 and GS1 128 DataBar and GS1 Composites Any application that accepts GS1 data can be simplified since it only needs to recog nize one data carrier...

Page 95: ...e Code 39 linear component The MicroPDF417 component can only be decoded if TLC39 On is selected The linear component may be decoded as Code 39 even if TLC39 is off Default Off QR Code Default All QR...

Page 96: ...proper number of codes is reached the data is output in the order specified in the bar codes Default On QR Code Page QR Code pages define the mapping of character codes to characters If the data rece...

Page 97: ...bar code with the append trigger character s it buf fers the number of Data Matrix bar codes determined by information encoded in those bar codes Once the proper number of codes is reached the data is...

Page 98: ...data characters should then appear properly MaxiCode Default All MaxiCode Settings MaxiCode On Off MaxiCode Message Length Scan the bar codes below to change the message length Refer to Message Length...

Page 99: ...r code with the append trigger character s it buffers the number of Aztec bar codes determined by information encoded in those bar codes Once the proper number of codes is reached the data is output i...

Page 100: ...ers should then appear properly Chinese Sensible Han Xin Code Default All Han Xin Settings Han Xin Code On Off Han Xin Code Message Length Scan the bar codes below to change the message length Refer t...

Page 101: ...n be active at a time If you scan a second 2D postal code selection the first selection is overwritten Default 2D Postal Codes Off Single 2D Postal Codes 2D Postal Codes Off Australian Post On British...

Page 102: ...and B Fields On InfoMail On InfoMail and British Post On Intelligent Mail Bar Code and Postnet with B and B Fields On Postnet and Postal 4i On Postnet and Intelligent Mail Bar Code On Postal 4i and In...

Page 103: ...n Planet Code Postnet and Intelligent Mail Bar Code On Planet Code Postal 4i and Intelligent Mail Bar Code On Postnet Postal 4i and Intelligent Mail Bar Code On Planet Code Postal 4i and Postnet with...

Page 104: ...tion is applied to customer fields in Australian 4 State symbols Bar Output lists the bar patterns in 0123 format Numeric N Table causes that field to be interpreted as numeric data using the N Table...

Page 105: ...ng Kong 2 of 5 Default All China Post Hong Kong 2 of 5 Settings China Post Hong Kong 2 of 5 On Off China Post Hong Kong 2 of 5 Message Length Scan the bar codes below to change the message length Refe...

Page 106: ...ription page 6 1 for addi tional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 Korea Post Check Digit This selection allows you to specify whether the check digit s...

Page 107: ...following chart indicates the equiva lents of these five characters for different countries Function Code HEX ASCII Value Full ASCII CTRL X Mode NUL 00 SOH 01 A STX 02 B ETX 03 C EOT 04 D ENQ 05 E AC...

Page 108: ...make ACK 06 CTRL break CNTRL break BEL 07 CR Enter RETURN BS 08 Reserved APPLE make HT 09 Tab TAB LF 0A Reserved APPLE break VT 0B Tab TAB FF 0C Delete Del CR 0D CR Enter RETURN SO 0E Insert Ins Help...

Page 109: ...moved when the unit is power cycled Show Decoder Revision Scan the bar code below to output the decoder revision Show Scan Driver Revision Scan the bar code below to output the scan driver revision Th...

Page 110: ...the scanner and receive scanner response that can be seen in the Scan Data window The data dis played in the Scan Data window can either be saved in a file or printed Configure Configure displays the...

Page 111: ...ve changed some options and want to restore the scan ner to factory default settings first scan the Remove Custom Defaults bar code then scan Activate Defaults This resets the scanner to the factory...

Page 112: ...8 4...

Page 113: ...example the SubTag for the RS232 baud rate is BAD Data The new value for a menu setting identified by the Tag and SubTag Storage A single character that specifies the storage table to which the comma...

Page 114: ...ice echoes back the command sequence with the status character inserted directly before each of the punctuation marks the period exclamation point comma or semicolon in the command Examples of Query C...

Page 115: ...Page Product Default Settings Setting Custom Defaults Set Custom Defaults MNUCDP 1 3 Save Custom Defaults MNUCDS 1 3 Resetting the Custom Defaults Activate Custom Defaults DEFALT 1 4 Programming the...

Page 116: ...Estonia KBDCTY41 2 7 Faroese KBDCTY83 2 7 Finland KBDCTY2 2 7 France KBDCTY3 2 7 Gaelic KBDCTY84 2 7 Germany KBDCTY4 2 7 Greek KBDCTY17 2 8 Greek 220 Latin KBDCTY64 2 8 Greek 220 KBDCTY61 2 8 Greek 3...

Page 117: ...ovenia KBDCTY31 2 11 Spain KBDCTY10 2 11 Spanish variation KBDCTY51 2 11 Sweden KBDCTY23 2 12 Switzerland French KBDCTY29 2 12 Switzerland German KBDCTY6 2 12 Tatar KBDCTY85 2 12 Turkey F KBDCTY27 2 1...

Page 118: ...PS 232BAD4 2 16 9600 BPS 232BAD5 2 17 19200 BPS 232BAD6 2 16 38400 BPS 232BAD7 2 17 57600 BPS 232BAD8 2 17 115200 BPS 232BAD9 2 17 Word Length Data Bits Stop Bits and Parity 7 Data 1 Stop Parity Even...

Page 119: ...L0 3 1 Low BEPLVL1 3 2 Medium BEPLVL2 3 2 High BEPLVL3 3 2 Beeper Pitch Good Read Frequency Low 1600 min 400Hz BEPFQ11600 3 2 Medium 2700 BEPFQ12700 3 2 High 4200 max 9000Hz BEPFQ14200 3 2 Beeper Pitc...

Page 120: ...e Scanning Mobile Phone PAPHHC 3 7 Reread Delay Short 500 ms DLYRRD500 3 8 Medium 750 ms DLYRRD750 3 8 Long 1000 ms DLYRRD1000 3 8 Extra Long 2000 ms DLYRRD2000 3 8 2D Reread Delay 2D Reread Delay Off...

Page 121: ...4 2 Suffix Add Suffix SUFBK2 4 2 Clear One Suffix SUFCL2 4 2 Clear All Suffixes SUFCA2 4 2 Function Code Transmit Enable RMVFNC0 4 3 Disable RMVFNC1 4 3 Intercharacter Delay Range 0 1000 5ms increment...

Page 122: ...e CBRCCT2 6 3 Codabar Message Length Minimum 2 60 4 CBRMIN 6 3 Maximum 2 60 60 CBRMAX 6 3 Code 39 Default All Code 39 Settings C39DFT 6 4 Off C39ENA0 6 4 On C39ENA1 6 4 Code 39 Start Stop Char Don t T...

Page 123: ...2 80 80 N25MAX 6 9 Code 93 Default All Code 93 Settings C93DFT 6 9 Off C93ENA0 6 9 On C93ENA1 6 11 Code 93 Message Length Minimum 0 80 0 C93MIN 6 9 Maximum 0 80 80 C93MAX 6 9 Code 93 Append On C93APP...

Page 124: ...NA0 6 15 On ISBENA1 6 15 Code 128 Message Length Minimum 0 80 0 128MIN 6 15 Maximum 0 80 80 128MAX 6 15 Code 128 Append On 128APP1 6 15 Off 128APP0 6 16 Code 128 Code Page Code 128 Code Page 2 128DCP...

Page 125: ...Check Digit Off UPECKX0 6 21 On UPECKX1 6 21 UPC E0 Number System Off UPENSX0 6 21 On UPENSX1 6 21 UPC E0 Addenda 2 Digit Addenda On UPEAD21 6 22 2 Digit Addenda Off UPEAD20 6 22 5 Digit Addenda On UP...

Page 126: ...SICHK0 6 27 Validate Type 10 and Transmit MSICHK1 6 27 Validate 2 Type 10 Chars but Don t Transmit MSICHK2 6 27 Validate 2 Type 10 Chars and Transmit MSICHK3 6 27 Validate Type 10 then Type 11 Char bu...

Page 127: ...MacroPDF417 On PDFMAC1 6 32 Off PDFMAC0 6 32 MicroPDF417 Default All Micro PDF417 Settings MPDDFT 6 33 On MPDENA1 6 33 Off MPDENA0 6 33 MicroPDF417 Msg Length Minimum 1 366 1 MPDMIN 6 33 Maximum 1 366...

Page 128: ...Aztec Code Settings AZTDFT 6 39 On AZTENA1 6 39 Off AZTENA0 6 39 Aztec Code Msg Length Minimum 1 3832 1 AZTMIN 6 39 Maximum 1 3832 3832 AZTMAX 6 39 Aztec Append On AZTAPP1 6 39 Off AZTAPP0 6 39 Aztec...

Page 129: ...6 42 Postnet and Intelligent Mail Bar Code On POSTAL16 6 42 Postal 4i and Intelligent Mail Bar Code On POSTAL17 6 42 Postal 4i and Postnet with B and B Fields On POSTAL19 6 42 Planet and Postnet On PO...

Page 130: ...45 Numeric N Table AUSINT1 6 45 Alphanumeric C Table AUSINT2 6 45 Combination N and C Tables AUSINT3 6 45 Utilities Add Code I D Prefix to All Symbologies Temporary PRECA2 BK2995C80 8 1 Show Decoder R...

Page 131: ...ensing Drop Withstands 1 5m drops 2 times Environmental Sealing IP40 Light Levels 0 to 100 000 lux 9 290 foot candles ESD 10kV Air 6kV contact Image Image Size 640 x 480 pixels Scan Performance Pitch...

Page 132: ...r may result in damage not covered by your warranty Serial Output 10 Pin RJ41 Modular Plug USB 10 Pin Modular Plug Required Safety Labels 1 Cable shield 2 Cable select 3 Supply ground 4 Transmit data...

Page 133: ...11 1 Replacing Cable in the Scanner The standard interface cable is attached to the scanner with an 10 pin modular connector When properly seated the connec tor is held in the scanner by a flexible re...

Page 134: ...may not be programmed for the appropriate terminal interface For example you scan 12345 and the host displays es Reprogram the scanner with the correct Plug and Play bar code See Programming the Inter...

Page 135: ...air or replace the product without charge except for return shipping to You jie EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR WARRAN...

Page 136: ...12 2...

Page 137: ...bar Fm 0 1 a 61 Code 11 H3 h 68 Code 128 Cm 0 1 2 4 j 6A Code 32 Pharmaceutical PARAF X0 3C Code 39 supports Full ASCII mode Am 0 1 3 4 5 7 b 62 TCIF Linked Code 39 TLC39 L2 T 54 Code 93 and 93i Gm 0...

Page 138: ...ode zm 0 9 A C z 7A Chinese Sensible Code Han Xin Code X0 H 48 Codablock A O6 0 1 4 5 6 V 56 Codablock F Om 0 1 4 5 6 q 71 Code 49 Tm 0 1 2 4 l 6C Data Matrix dm 0 6 w 77 GS1 em 0 3 y 79 GS1 Composite...

Page 139: ...II CTRL X Mode Control X Mode Off KBDCAS0 Windows Mode Control X Mode On KBDCAS2 DEC HEX Char CTRL X CTRL X function 0 00 NUL Reserved CTRL 1 01 SOH NP Enter CTRL A Select all 2 02 STX Caps Lock CTRL...

Page 140: ...72 48 H 104 68 h 41 29 73 49 I 105 69 i 42 2A 74 4A J 106 6A j 43 2B 75 4B K 107 6B k 44 2C 76 4C L 108 6C l 45 2D 77 4D M 109 6D m 46 2E 78 4E N 110 6E n 47 2F 79 4F O 111 6F o 48 30 0 80 50 P 112 7...

Page 141: ...146 92 F3 0x3D 147 93 F4 0x3E 148 94 F5 0x3F 149 95 F6 0x40 150 96 F7 0x41 151 97 F8 0x42 152 98 F9 0x43 153 99 F10 0x44 154 9A F11 0x57 155 9B F12 0x58 156 9C Numeric Keypad 0x4E 157 9D Numeric Keyp...

Page 142: ...197 C5 198 C6 199 C7 200 C8 201 C9 202 CA 203 CB 204 CC 205 CD 206 CE 207 CF 208 D0 209 D1 210 D2 211 D3 212 D4 213 D5 214 D6 215 D7 216 D8 217 D9 218 DA 219 DB 220 DC 221 DD 222 DE 223 DF 224 E0 225...

Page 143: ...F5 246 F6 247 F7 248 F8 249 F9 250 FA 251 FB 252 FC 253 FD 254 FE 255 FF Code Page Selection Method Country Standard Keyboard Country Honeywell Code Page Option United States standard ASCII ISO IEC 6...

Page 144: ...ain ISO IEC 646 17 10 90 Spain ISO IEC 646 85 51 91 Dec 35 36 64 91 92 93 94 96 123 124 125 126 Hex 23 24 40 5B 5C 5D 5E 60 7B 7C 7D 7E US 0 1 CA 54 95 CA 18 96 JP 28 98 CN 92 99 GB 7 87 FR 3 83 DE 4...

Page 145: ...4 59 3A 3B 3C 3E 3F 38 40 3D 5A 5F 64 5B 60 65 5C 61 66 5D 62 67 63 68 69 6A 6C 104 Key U S Style Keyboard 6E 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 4B 50 55 4C 51 56 01 02 03 04 05 06 07 08 09...

Page 146: ...A 10...

Page 147: ...Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 1234567890 EAN 13 9 780330 290951 Code 128 Code 128 Code 39 BC321 Codabar A13579B Code 93 123456 9 Straight 2 of 5 Industrial 123456...

Page 148: ...6543210 Matrix 2 of 5 GS1 DataBar 01 00123456789012 PDF417 Car Registration Data Matrix Test Symbol QR Code Numbers Aztec Package Label MaxiCode Test Message Micro PDF417 Test Message Postnet Zip Code...

Page 149: ...4 CB 4 State Customer Bar Code 01 234 567094 987654321 01234567891 ID tag UPU 4 State J18CUSA8E6N062315014880T...

Page 150: ...Programming Chart 0 1 2 3 4 5 6 7 8 9...

Page 151: ...Programming Chart Note If you make an error while scanning the letters or digits before scanning Save scan Discard scan the correct letters or digits and Save again A B C D E F Save Discard Reset...

Page 152: ...YJ HF500 ENUS UG Rev A 10 15...