background image

EPDT-263b

 

 

5. Installation 

 

5.1 Piping Example 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 

 

 

 

 

 

             

Table 1. Weight of Cover Set 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
1.  Clogging  condition  inside  the  product  can  be  known  from  the  differential  pressure  measured  when 

pressure gauges are installed before and after the product (see Fig. 2).     

2.  If fluid flows from bottom to top, install a blow valve in order to remove scale accumulated at the bottom of 

riser pipe (see Fig. 3).   

 

Size 

Weight (kg) 

125A 

12 

150A 

17 

200A 

28 

250A 

41 

Fig. 2 

Fig. 3 

Pressure 

gauge 

Pressure 

gauge 

Blow 

valve 

Summary of Contents for ST-10

Page 1: ...ould result in death or serious injury Caution This symbol indicates a hazardous situation that if not avoided may result in minor or moderate injury or may result in only property damage Table of Con...

Page 2: ...installation 2 Material Body Ductile cast iron Screen Stainless steel Connection Perforation 8 10P Mesh Standard 60 mesh 3 Rust proof Electrodeposition coating 1 Available with davit for 250A 2 If flu...

Page 3: ...ug 5 Screen 14 Bolt 6 Handle 15 Plug 7 O ring 16 Eye bolt 8 O ring 17 Name plate 9 Thumbscrew 18 Rivet Eye bolt 16 is available only for 150 to 250A Nominal size L H1 H2 Screen Plug 13 Plug 15 Weight...

Page 4: ...h Davit Nomin al size L H1 H2 Screen Plug 13 Plug 15 Weight kg ds ls 250A 550 215 285 258 278 R1 2 R3 8 156 No Parts name Davit Davit handle Hanging bracket bracket Weight kg 160 Davit mounting positi...

Page 5: ...equipment see Fig 1 Pressure Loss Chart Fig 1 Pressure Loss Chart For Water As a reference the standard flow velocity is specified in the Japanese Industrial Standards JIS as a guide to select an app...

Page 6: ...differential pressure measured when pressure gauges are installed before and after the product see Fig 2 2 If fluid flows from bottom to top install a blow valve in order to remove scale accumulated a...

Page 7: ...operly 2 Make sure to support pipes and to secure the product firmly If an excessive piping stress is applied the product may be deformed 3 When installing secure the space required for maintenance or...

Page 8: ...er for the flow rate see Fig 1 Pressure Loss Chart on Page 3 Foreign substances are not removed 1 The screen 5 is damaged 1 Disassemble the product and replace the screen 5 with a new one 2 The O ring...

Page 9: ...on once a year Add the following item to the above daily inspection items Item How to inspect When abnormality is found Clogging of the screen 5 Disassemble the product and check the screen 5 visually...

Page 10: ...f the stopper ring is not turned smoothly lift the handle strongly The cover is pushed down and the stopper ring can be turned smoothly 2 To remove the cover do not lift the both handles at the same t...

Page 11: ...se the O ring to be damaged 3 If the screen is deformed or damaged replace it with a new one Failure to follow this notice may keep the product from functioning properly 4 If the O ring is damaged or...

Page 12: ...is not engaged with the stopper by the thumbscrew The handle is not between the stopper 5 Rotate the stopper ring until each handle reaches the stopper 4 Install the cover to the body Push in the cove...

Page 13: ...ice life listed on table below is only reference No Parts name Service life reference 7 O ring 3 years 8 O ring 3 years 5 Screen 5 years Eye bolt 16 16 is available only for 150 to 250A Bolt 10 14 Bol...