background image

 

 

 

4. Troubleshooting 

 

Trouble 

Cause 

Remedy 

Outside leakage 

  1. The gland nut is loosened. 

1. Tighten the gland nut additionally. 

  2. The gland packing is damaged.    2. Replace the product with new one. 

3. The spindle is damaged. 

3. Replace the product with new one. 

Leakage  from  the 
valve  and/or  valve 
seat  on  complete 
closing 

1.  The  valve  and/or  valve  seat  is 

damaged. 

1. Replace the product with new one. 

2. Foreign substance is stuck. 

2. Remove the foreign substance. 

Operation  torque  of 

the 

handle 

is 

abnormally large 

1.  Too  much  tightening  of  the 

gland nut. 

1. Loosen the gland nut and tighten it again to 

the no leakage degree. 

2.  Foreign  substance  is  stuck  on 

spindle and screw part. 

2. Remove the foreign substance. 

Abnormal sound   

1. Each screw part is loosened. 

1. Retighten the loosened parts. 

 

5. Maintenance 

 

 

Warning 

Completely  discharge  the  pressure  inside  of  the  product,  line  and  equipment  before  inspection  and 

maintenance. For high temperature fluid, cool down the product till it can be touched with bare hands. 

* Failure to follow this notice may result in injury or burns due to residual pressure. 

 

Periodic inspection 

Please conduct periodic inspection about once a year in order to maintain optimal performance and 

function of the product. 

Inspection item 

Opening and closing operation 

Abnormal sound 

Outside leakage 

If any abnormality is found, see “4. Troubleshooting” and conduct appropriate measure. 
 

6. After service 

1.  Limited warranty 

This product has been manufactured using highly-advanced techniques and subjected to strict quality control. Please be 

sure to use the product in accordance with instructions on the manual and the label attached to it. 

Yoshitake  warrants  the  product  to  be  free  from  any  defects  in  material  and  workmanship  under  normal  usage  for  a 

period of one year from the date of receipt by the original user, but no longer than 24 months from the date of shipment 
from Yoshitake’s factory. 

2. Parts supply after product discontinuation 

This  product  may  be  subject  to  discontinuation  or  change  for  improvement  without  any  prior  notice.  After  the 

discontinuation of the product, Yoshitake supplies the repair parts for 5 years otherwise individually agreed. 

3

This warranty does not cover the damage due to any of below: 

(1) Valve seat leakage or malfunction caused by foreign substances inside piping. 
(2) Improper handling or misuse. 
(3) Improper supply conditions such as abnormal water pressure/quality. 
(4) Water scale or freezing. 
(5) Trouble with power/air supply. 
(6) Any alteration made by other than Yoshitake. 
(7) Use under severe conditions deviating from the design specifications (e.g. in case of corrosion due to outdoor use). 
(8) Fire, flood, earthquake, thunder and other natural disasters. 
(9) Consumable parts such as O-ring, gasket, diaphragm and etc. 
Yoshitake is not liable for any damage or loss caused by malfunction or defect of the product. 

4

On repair request after warranty is expired 

In case that performance of the product can be maintained, we repair the product with charge on customer’s request. 

 

 
 

INTERNATIONAL DEPT.    955-5, Miyamae, Irukadeshinden, Komaki, Aichi, 485-0084, Japan 

Phone: +81-568-75-4432 Fax: +81-568-75-4763 E-mail: [email protected] 