![Yoshitake GD-20R Manual Download Page 17](http://html2.mh-extra.com/html/yoshitake/gd-20r/gd-20r_manual_4902960017.webp)
- 16 -
■
EPDT-023c
■
U nut
⑰
Spring plate
⑫
Spindle
⑥
Bolt
㉘
Retainer guide
⑤
[Nominal Size: 15A~50A]
To remove the retainer guide [5] easily, install the spring plate [12] and U nut [17] to spindle
[6] again and pull the spring plate [12]. (Fig. 14)
Fig. 14
[Nominal Size: 65A~150A]
To remove the retainer guide [5] easily, screw the bolt [28] to retainer guide [5] and pull it.
(Fig.15)
Fig. 15
7.5 Assembly
When assembling, follow the steps in the reverse order of disassembly.
※
Precautions during assembly
(1)
Make sure that the diaphragm [11], the valve seat [8], and the valve [9] have no scratches.
(2)
Apply the silicon grease to the O-Ring [7] after confirm whether there is any flaw on the O-Ring.
(3)
Install the spring chamber [2] after the confirm whether the border of diaphragm [11] is
fitted with the groove of body [1].
(4)
It is normal for there to be a gap between the retainer guide [5] and the main body [1]. Tighten
the bolts evenly and be careful not to overtighten them.