YO People Counter
User guide
v1.0
page 6/35
Operating conditions
OPERATING CONDITIONS
Temperature
0° to 70°C
Humidity
0 to 90%
Placement
Indoor use
Power supply
USB-C 5 V DC
6 - 30 V DC
5 - 21 V AC
Power consumption
44 mA (normal work), 100 mA (max peak) - at 5V supply
voltage
Technology
Radar
Frequency: 24 GHz
Beam Aperture: 80° / 34°
Range: 10-500cm
Measured values
MEASUREMENT RANGES
Parameter
Measuring range
Accuracy
Temperature (internal)
-40°C to 125°C
±0,2°C (from 5°C to 60°C )
Relative humidity
0% to 100%
±2% (at 20% to 80% )
Left-to-right counter
0-2147483647 ( int32 )
-
Right-to-left counter
0-2147483647 ( int32 )
-
Sum-of-left to right counts
0-2147483647 ( int32 )
-
Sum-of-right to left counts
0-2147483647 ( int32 )
-
Difference between sum
counts
0-2147483647 ( int32 )
-
Internal Temperature and relative internal humidity
Sensors placed inside the device enclosure measure temperature and relative humidity. These
measurements monitor if the device is working in recommended conditions.
REV 1.0