background image

2

YX SERIES

Specifications

Model

YX18SP

System Type

Subwoofer

Active or Passive

Active

Program Power (Watts)

500 Watts

Max SPL (dB)

123 dB (continuous)

Frequency Response (Hz +/- 3db)

45-150Hz

Crossover Frequency (Hz)

80Hz

LF Driver(s)

18-inch ceramic

Inputs

1 x Combi-Jack (l/mono) 1 x XLR (right)

Outputs

2 x XLR Link Thru / 2 x XLR High Pass (80Hz crossover) 

Other Controls / Features

Gain Control, Ground Li€, Integrated Crossover(80Hz High 
Pass Output for Top Cabinets)

Corners

Metal

Feet

Rubber

Wheels

No

Bar Handles

2 (side)

Pole Mount Adapter (1 3/8-inch/3.5cm)

Yes (top)

Enclosure Materials

15 mm (5/8-inch) plywood

Grille

Custom Punched Black Perforated Metal

Covering / Finish

Black Ozite

Dimensions (DWH xbackW, inches)

26 x 22 x25

Dimensions (DWH xbackW, cm)

66 x 55.9 x 63.5

Weight (lbs/kg)

74 / 33.6

4. High Pass Output Jacks

High Pass Output jacks are provided to eliminate the need for an external crossover. Use 

these jacks to feed the input of your full-range loudspeakers. The signal leaving these XLR 

jacks has had the audio below 80 Hz removed, allowing for a flat system response when 

feeding the full-range loudspeakers. 

5. Ground Lift Switch

In normal operation, keep the Ground Lift switch in the depressed position. If an audible hum is 

present in your system, try “lifting” the ground to break a ground loop in your system.

6. Protection and Indicators

The YX18SP has circuitry to prevent clipping, over current and over excursion. At high levels the 

internal limiter will limit the gain of the YX18SP and hence if the user attempts to set the subwoofer 

level control at a high level, the resulting setting will be incorrect. The level control should be set 

while operating at low levels (under 10 watts). If the level control is set too high, the input circuit 

will clip and the dynamics of the bass will be lost. 

In normal operation, the rear indicator will flash green when a signal is present. When the 

indicator starts flashing red, the limiter is engaging. Increasing the input signal beyond this point 

will potentially result in clipping.

AT HIGH POWER LEVELS WHEN THE LIMITER IS OPERATING INCREASING THE SUBWOOFER 

LEVEL CONTROL WILL NOT INCREASE THE OUTPUT. DO NOT INCREASE SETTING WHILE 

OPERATING AT HIGH LEVELS.

Summary of Contents for YX18SP

Page 1: ...YX SERIES YX18SP 500 WATT POWERED SUBWOOFER LOUDSPEAKER ENCLOSURE MODEL TYPE YS2007 OWNER S MANUAL MANUEL DE L UTILISTEUR ...

Page 2: ...n spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped AVIS AFIN DE REDUIRE LES RISQUE DE CHOC ELECTRIQUE N ENLEVEZ PAS LE COUVERT OU LE PANNEAU ARRIERE NE CONTIENT AUCUNE PIECE REPARABLE PAR L UTILISATEUR CONSULTEZ UN TECHNICIEN QUALIFIE POUR L ENTRETIENT Instructions relatives au risque de feu choc élec...

Page 3: ...listening while operating at a medium level i e before the onset of limiting and then not changed It is not possible to set this control properly at high levels since the limiter will be determining the output level A setting of 0 dB on the YX18SP Level control is the correct starting point when setting up a sound system From there adjustments can be made for the best sound The 0 dB mark refers to...

Page 4: ...he audio below 80 Hz removed allowing for a flat system response when feeding the full range loudspeakers 5 Ground Lift Switch In normal operation keep the Ground Lift switch in the depressed position If an audible hum is present in your system try lifting the ground to break a ground loop in your system 6 Protection and Indicators The YX18SP has circuitry to prevent clipping over current and over...

Page 5: ... l écoute lors d une opération à un niveau moyen c est à dire avant l apparition de la limitation et devrait ensuite demeuré inchangée Il n est pas possible de régler correctement cette commande lors d opération à niveau élevé puisque le limiteur déterminera dans ce cas le niveau de sortie Le réglage à 0 dB de la commande de niveau du YX18SP est le bon point de départ lors de l ajustement initial ...

Page 6: ... watts Si la commande de volume est à un niveau trop élevé le circuit d entrée écrêtera le signal et la dynamique de la basse sera perdu Durant le fonctionnement normal l indicateur de l arrière clignote avec une couleur verte lorsqu un signal est présent L indicateur vous informe que le limiteur est engagé lorsqu il commence à clignoter avec une couleur rouge L augmentation du niveau du signal d ...

Page 7: ...3 1 2 3 1 Σ YX SERIES YX18SP 500 WATT POWERED SUBWOOFER LOUDSPEAKER ENCLOSURE Ground Lift 80 Hz XLR male 1 4 inch Phone XLR male XLR male XLR male XLR female XLR female RIGHT Input RIGHT Link LEFT MONO Input LEFT High Pass Out RIGHT High Pass Out LEFT Link 80 Hz ...

Page 8: ...6 YX SERIES ...

Page 9: ...7 YX SERIES ...

Page 10: ...8 YX SERIES ...

Page 11: ...e de faire enregistrer votre nom auprès de Yorkville Sound ou de votre détaillant Si pour une raison quelconque ce produit devient défectueux durant les deux années qui suivent la date d achat initial dix ans pour l ébénisterie retournez le simplement à votre détaillant Yorkville avec la preuve d achat original et il sera réparé gratuitement Ceci inclus tous les produits Yorkville à l exception de...

Page 12: ...Niagara Falls New York 14305 USA Voice 716 297 2920 Fax 716 297 3689 WORLD HEADQUARTERS CANADA Yorkville Sound 550 Granite Court Pickering Ontario L1W 3Y8 CANADA Voice 905 837 8481 Fax 905 837 8746 Printed in China Manual Owners YX18SP 00 1v1 January 9 2011 ...

Reviews: