background image

2

1. Power Switch and Indicator 

The green power LED illuminates when the power switch is turned to the On position and AC voltage is sup-

plied. When the power is removed or the power switched is moved to the off position the green power indicator 

will blink while the power supply is discharging. The processing circuitry will not reboot unless the power supply 

is fully discharged before being turned back on. It is not necessary to reboot however. Turning the power back 

on before the power supply is discharged will simply resume normal operation.

2. PowerCON TRUE AC Loop Thru 

As a standard, the AC inlet on the SA115S accepts locking PowerCON TRUE power cords. There is also an AC 

outlet that can be used to loop power through to other cabinets in your array using a male to female PowerCON 

TRUE looping power cord. Check with your local Yorkville dealer for availability of these accessory cords.

IMPORTANT: DO NOT EXCEED THE CURRENT RATING OF THE POWER and ACCESSORY CORDS. 

PLEASE READ THE SECTION OF THIS MANUAL CALLED CASCADE INSTALLATION 

3. Input Jack 

This female-XLR accepts line level XLR microphone cables. For best noise reduction use balanced sources.

4. Dual Link Outputs

These XLR male connectors can be used with a standard XLR cable to daisy-chain up to 20 SA115S cabinets 

without signal degradation. Simply loop from one cabinet’s Link jack to the next cabinets Input jack. In many 

cases this limit of 20 cabinets can be exceeded, consult Yorkville Sound for more details.

5. SA115S Level Control

This control adjusts the volume level of the SA115S relative to the input signal level. Mixers and other audio 

sources connected to the SA115S tend to have different output voltages, which mean the level control on the 

SA115S is used to fine tune the cabinet’s volume relative to the mixer settings. It is perfectly acceptable to set 

the SA115S Level above or below the center 0 dB setting.

6. Clip, X-Max, VC-Therm, Activity Indicators

The Clip and Limit LED indicators illuminate to guide the user to proper operating levels.

Illumination either of the yellow Limit LEDs indicates that a level has been reached where the SA115S limit-

ers are reducing the signal internally to prevent damage or distortion. It also indicates that further increases in 

input level or increasing the SA115S Level control position will not appreciably increase acoustic output. 

The red Clip LED indicates that the input level is excessive and further increases in level will cause severe 

distortion The input signal should be reduced at the source until Clip activity ceases. The clip indicator comes 

on at 12 Vrms,16 volts peak. The input clips at 17 Vrms, 24 volts peak.

The activity Indicator comes on at 5 mVrms or -45 dBV.

7. Line Current Limit Control

The Line Current Limit control allows the power to be reduced to allow operation on limited power availabil-

ity. Full power transients will be allowed through but if the average power is excessive then the power will be 

limited. This control works by advancing the limiter that limits the voice coil temperature and by monitoring 

the current draw. In the 5 amp (2.5 amp CE) position the average power is limited only by the voice coil tem-

perature. In the 4 amp (2 amp CE) position with most music, the limiter will be only active occasionally de-

pending on the music content. In the 3 amp (1.5 amp CE) position certain types of music will not be limited, 

primarily music without deep bass or where the bass is unprocessed. The 2 amp (1 amp CE) position will 

significantly reduce the output when the music content has continuous bass content below 45 Hz. The green 

power on indicator will dim to indicate when the line current limiter is active. A small amount of dimming 

indicates that the advanced thermal limiter is active while significant dimming indicates that the line current 

monitoring system has detected excessive line current. Low line voltage typically due to long power supply 

cables may cause excessive line current, the line current monitoring system will prevent this from tripping 

the power source circuit breakers.

Summary of Contents for Synergy SA115S

Page 1: ...OWNER S MANUAL MANUEL DE L UTILISATEUR SA1 15S ...

Page 2: ...urs qui produisent de la chaleur Les dispositifs marqués d une symbole d éclair sont des parties dangereuses au toucher et que les câblages extérieurs connectés à ces dispositifs de connection extérieure doivent être effectivés par un opérateur formé ou en utilisant des cordons déjà préparés Cordon d Alimentation Ne pas enlever le dispositif de sécurité sur la prise polarisée ou la prise avec tige...

Page 3: ...n be advanced to limit the power draw in cases where there is less than ample power available The X Max limiter is faster pretty much instantaneous The VC thermal limiter is slower reacting typically operating near the end of a bass beat at 120 bpm The amplifier is a high headroom Class D design There is a large capacitor bank so that bass transients are less dependent on the quality of the power ...

Page 4: ...Indicators The Clip and Limit LED indicators illuminate to guide the user to proper operating levels Illumination either of the yellow Limit LEDs indicates that a level has been reached where the SA115S limit ers are reducing the signal internally to prevent damage or distortion It also indicates that further increases in input level or increasing the SA115S Level control position will not appreci...

Page 5: ...peut être avancé pour limiter la consommation d énergie dans les cas où il n y a pas assez de puissance disponible Le limiteur X Max est plus rapide presque instantané Le limiteur VC thermal réagit plus lentement et fonc tionne généralement vers la fin d un battement de basse à 120 bpm L amplificateur est une conception de classe D à haute extension dynamique Il est équipé d une grande banque de c...

Page 6: ... Clip X Max VC Therm Les indicateurs DEL Clip et Limit s allument pour guider l utilisateur vers les niveaux de fonctionnement appropriés L illumination de l une ou l autre des DEL jaunes de limite indique qu un niveau a été atteint où les limiteurs du SA115S réduisent le signal de façon interne pour éviter tout dommage ou distorsion Il indique égale ment que d autres augmentations du niveau d ent...

Page 7: ...4500 watts Program 9000 watts peak Measured Max SPL C Weighted Max Hold 129dB Cont 135 dB Peak Frequency Response Hz 3dB 31 Hz 100 Hz Crossover Frequency Hz 100 Hz lowpass Cabinet Configuration Tapped Horn Driver Configuration 1x15 inch LF woofer LF Driver s 15 inch Neodymium with 4 5 inch Voice Coil LF Program Power watts 4500 watts program 9000 watts peak LF Impedance ohms 4 ohm Load LF Protecti...

Page 8: ... A N U FA C T U R E D B Y Y O R K V I L L E S O U N D block diagram SYNERGY SA115S 00 1v0 Output Input XLR Sub Level 50Hz LP AC Line Current Sense Line Current Limit Microcontroller DSP ADC DAC 2 3 1 2 3 1 1 3 2 AMP Act VC Therm X Max Input Clip Limit Pwr ...

Page 9: ...ctrical cords that have worn or damaged insulation and remember to pull the plug not the cord to prevent damage to the cord Only replace with the equivalent heavy duty cord supplied by the manufacturer 4 The AC supply cord should be routed so that it is unlikely that it will be damaged Protect the power cord from being walked on or pinched If the AC supply cord is damaged DO NOT OPERATE THE UNIT T...

Page 10: ...gée et n oubliez pas de tirer sur la fiche et non sur le cordon pour éviter d endommager ce dernier Ne remplacez le cordon électrique que par un cordon équivalent à usage intensif fourni par le fabricant 4 Le cordon d alimentation CA doit être acheminé de manière qu il soit peu probable qu il soit endommagé Protégez le cordon d alimentation pour qu il ne soit pas piétiné ou pincé Si le cordon d al...

Page 11: ...re nom auprès de Yorkville Sound ou de votre détaillant Si pour une raison quelconque ce produit devient défectueux durant les deux années qui suivent la date d achat initial dix ans pour l ébénisterie retournez le simplement à votre détaillant Yorkville avec la preuve d achat original et il sera réparé gratuitement Ceci inclus tous les produits Yorkville à l exception de la série de moniteurs de ...

Page 12: ...e Niagara Falls New York 14305 USA Voice 716 297 2920 Fax 716 297 3689 WORLD HEADQUARTERS CANADA Yorkville Sound Limited 550 Granite Court Pickering Ontario L1W 3Y8 CANADA Voice 905 837 8481 Fax 905 837 8746 Manual Owners SYNERGY SA115S 00 1v2 June 24 2022 ...

Reviews: