background image

Introduction

The LS700P is a premium quality integrated powered subwoofer and amplifier. Created as an 

easy-to-setup addition to your PA, the LS700P will extend the bass of a typical sound system with a 

minimum of complication, and hence is intended primarily to operate with speaker level signals.

Configuration

The LS700P may be used in several different configurations, the minimum standard system is 

one LS700P used with a pair of full range speakers. The LS700P accepts the signal from sepa-

rate Left and Right sources simultaneously. It then combines them into one signal (to drive the 

internal speakers). When used in a setup where only one signal is provided to a speaker, such 

as a mono system or stereo with more than one LS700P, use either the Left or Right input.

LS700P

Yorkville

DESIGNED & MANUFACTURED BY YORKVILLE SOUND • TORONTO, CANADA

INPUT GROUND

INPUT LEVEL

LEFT

(mono)

RIGHT

USER NOTE:

This 

Subwoofer

 may be driven from Speaker Level 

or Line Level signals. If an 

élite processor

 is used, 

this Subwoofer should be plugged into the 

SUB 

output of the processor. The 

High–Frequency 

Cutoff

 

should be set to

 150-Hz 

and the 

Input Level 

should be set to 

LINE. 

For 

Line Level 

operation a 

balanced (

Tip Ring Sleeve)  

cable should be used. If the 

system is being operated 

without a processor, this 

Subwoofer 

can be 

connected to the output of 

the power amplifier as shown 

in the diagrams and the 

Input Level

 should be set to 

SPEAKER

. If none of the 

equipment has a 

U-ground,

 

the 

INPUT GROUND

 should be set to 

GROUNDED. Otherwise the 

INPUT 

GROUND

 should be set to the 

position that best minimizes the hum.

Refer to the Owner's Manual 

for other modes of operation

HIGH

FREQUENCY

CUT OFF

125 Hz

POWER

100 Hz

150 Hz

SUBWOOFER

LEVEL

PARALLEL

THRU 

I

N

P

U

T

PARALLEL

THRU 

I

N

P

U

T

UNGROUNDED

GROUNDED

SPEAKER

LINE

ON POWER

LS700P

SUBWOOFER

POWER

AMPLIFIER

FULL–RANGE

SPEAKERS

Left

Right

Left

Right

ONE SUBWOOFER PER SYSTEM

LS700P

SUBWOOFER

LS700P

SUBWOOFER

POWER

AMPLIFIER

FULL–RANGE

SPEAKER 

FULL–RANGE

SPEAKER 

TWO SUBWOOFERS PER SYSTEM

R

L

CAUTION: 

REPLACE WITH

SAME TYPE  FUSE AND RATING

ATTENTION:

 UTILISER UN FUSIBLE DE

RECHANGE DE MEME TYPE ET CALIBRE

-5

-10

+10

+24

+20

dB

0

A-Z100B / 1v40

TYPE: ES700P

Yorkville

230V   

50Hz 1.3A

120V      

60Hz 2.5A 

LR 21877

FUSE: T3,15A GDC

FUSE: T5.0A 250V 

SLO~BLO

 

For normal operation connect the 

LS700P

LS700P

LS700P

LS700P

LS700P

LS700P

 just like an ordinary speaker along with the full range speakers. The

"

INPUT LEVEL

" switch should be set to "

SPEAKER

 ." If the audio source does not have a "U" ground, eg. a ground pin on

the AC cord, the "

INPUT GROUND

" switch must be set to "

GROUNDED

." The 

 may be wired before or after

the full range speakers. Use the left and right inputs when using a single 

 in a stereo system. Use either

the left or right inputs when using separate 

's for each side or when used in a mono system. The

 does not alter the signal to the full range speakers in any way. The 

 will not draw any

power from the amplifier driving the full range speakers. Please note that an external cross-over is not necessary.

1. Hi Frequency Cutoff Control

This control varies the frequency at which 

the LS700P rolls off the high frequencies. 

This provides part of a crossover function. 

This crossover function also combines with 

the natural low frequency roll off inherent 

of the full range cabinet (when the LS700P 

is not used with an élite processor). This 

control should be set to the closest possible 

frequency to 20 Hz below the crossover 

point that the full range speakers processor 

uses as it's crossover point.

If an élite processor is used, set the high 

frequency cutoff to maximum (160 Hz)  

2. Subwoofer Level Control

The subwoofer level control adjusts the 

amount of bass added to the sound 

system by the LS700P. This adjusts for the 

relative sensitivity of the companion full 

range speakers and the desired system 

frequency response. This control should 

be set by listening while operating at a 

medium level and then not changed. It is 

not possible to set this control properly at 

high levels since the limiter is determining 

the output level. Setting the level too high 

will over load the circuitry causing a loss 

of bass dynamics. The level control should 

not be set above the 9 o’clock position 

Summary of Contents for ES700P - SERVICE

Page 1: ...LS700P OWNER S MANUAL MANUEL de L UTILISATEUR Yorkville MODEL TYPE ES700P ...

Page 2: ...lacement of the obsolete outlet The AC supply cord should be routed so that it is unlikely that it will be damaged If the AC supply cord is damaged DO NOT OPERATE THE UNIT Unplug this apparatus during lightning storms or when unused for long periods of time Service The unit should be serviced only by qualified service personnel AVIS AFIN DE REDUIRE LES RISQUE DE CHOC ELECTRIQUE N ENLEVEZ PAS LE CO...

Page 3: ...WO SUBWOOFERS PER SYSTEM R L CAUTION REPLACE WITH SAME TYPE FUSE AND RATING ATTENTION UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE ET CALIBRE 5 10 10 24 20 dB 0 A Z100B 1v40 TYPE ES700P Yorkville 230V 50Hz 1 3A 120V 60Hz 2 5A LR 21877 FUSE T3 15A GDC FUSE T5 0A 250V SLO BLO For normal operation connect the LS700P LS700P LS700P LS700P LS700P LS700P just like an ordinary speaker along with the full ...

Page 4: ... tween speaker level and line level The switch should be set to speaker level when the LS700P is fed from the output of an amplifier or pow ered mixer The line level position is for when the LS700P is fed a signal from a processor elec tronic crossover or the output of an unpowered mixer When using the line level mode the use of balanced Tip Ring Sleeve cables will reduce the sensitivity to hum an...

Page 5: ...WOOFERS PER SYSTEM LS700P SUBWOOFER LS700P SUBWOOFER POWER AMPLIFIER FULL RANGE SPEAKER FULL RANGE SPEAKER Right Left config02e ls700p eps ONE SUBWOOFER WITH MONO SYSTEM LS700P SUBWOOFER POWER AMPLIFIER FULL RANGE SPEAKER s Output config01e ls700p eps ONE SUBWOOFER WITH STEREO SYSTEM LS700P SUBWOOFER POWER AMPLIFIER FULL RANGE SPEAKERS Left Right Left Right config03e ls700p eps ONE SUBWOOFER USING...

Page 6: ...r Switch Yes Power Consumption typ max 300 480VA 4A 60hz 2A 50hz Inputs 1 4 Jacks 2 line speaker level inputs 2 link in out Level Controls Main Volume EQ Controls High Frequency Cut Off Selectable line or speaker level input Ground lift switch Corners Black Steel Feet Plastic Glides Bar Handles 2 side mounted Enclosure Materials 3 4 inch 7 ply Spruce Grille Heavy gauge perforated metal Covering Fi...

Page 7: ...SLO BLO Pour opération normale branchez simplement le comme un cabinet ordinaire avec les cabinets pleine gamme Réglez le commutateur INPUT LEVEL à la position SPEAKER Le commutateur INPUT GROUND doit être réglé à la position GROUNDED si l appareil de source sonore n est pas munis d un cordon d alimentation avec lame de mise à la terre Le peut être branché avant ou après les cabinets pleine gamme ...

Page 8: ... SWITCH à la position GROUNDED sinon laissez le commutateur à la position UNGROUDED N utilisez pas la position GROUNDED avec un amplificateur branché en pont ou lorsque le manchon du signal d entrée est sous tension A des niveaux élevés lorsque le limiteur est activé augmenter le réglage du contrôle de niveau n augmentera pas le niveau de sig nal de sortie N augmentez pas le réglage du niveau lors...

Page 9: ...e le limiteur détermine le niveau de sortie il est impossible de régler ce contrôle à des niveaux élevés LS700P Examples de Configuration DEUX LS700P PAR SYSTÈME LS700P LS700P AMPLIFICATEUR ENCEINTE PLEINE GAMME ENCEINTE PLEINE GAMME Droitie Gauche config02f ls700p eps UN LS700P AVEC SYSTÈME MONO LS700P AMPLIFICATEUR Enceinte s Pleine Gamme Sortie config01f ls700p eps UN LS700P AVEC SYSTEME STÉRÉO...

Page 10: ...i Commutateur de mise en marche Oui Consomation de puissance typ max 300 480VA 4A 60hz 2A 50hz Entrées 1 4 Jacks 2 entrées niveau ligne HP 2 link entrée sortie Contrôles de Niveau Volume Principale Contrôle d égalisation Coupure des fréquences aiguës Entrée commutable entre niveau ligne et niveau HP Sélecteur de débranchement de la mise à la terre Coins En métal noire Pieds Plastique Poignés 2 mon...

Page 11: ...e de faire enregistrer votre nom auprès de Yorkville Sound ou de votre détaillant Si pour une raison quelconque ce produit devient défectueux durant les deux années qui suivent la date d achat initial dix ans pour l ébénisterie retournez le simplement à votre détaillant Yorkville avec la preuve d achat original et il sera réparé gratuitement Ceci inclus tous les produits Yorkville à l exception de...

Page 12: ...4625 Witmer Industrial Estate Niagara Falls New York 14305 USA Voice 716 297 2920 Fax 716 297 3689 WORLD HEADQUARTERS CANADA Yorkville Sound 550 Granite Court Pickering Ontario L1W 3Y8 CANADA Voice 905 837 8481 Fax 905 837 8746 ...

Reviews: