The LS200P powered subwoofer incorporates a 200 Watt amplifier. It can be used to enhance the 

bottom end (bass) of a full-range speaker system and increase the overall output of the system. 

The inputs to the subwoofer can accept a single source either from a speaker/amplifier output or 

a line level output from a pre-amp or mixer.

The LS200P

 

also has a built in limiter and thermal

 protection

 that make this product smooth 

and robust at high power levels. The internal limiter and the internal protection are factory set to 

maximize performance.

LS200P

Yorkville

DESIGNED & MANUFACTURED BY YORKVILLE SOUND • TORONTO, CANADA

POWER

SUBWOOFER

LEVEL

POWER

ON

INPUT

PARALLEL

THRU 

INPUT

GROUND

INPUT LEVEL

UNGROUNDED

GROUNDED

SPEAKER

LINE

Yorkville

230V   

50Hz

1.1A

120V    

60Hz

2.2A

CAUTION: REPLACE WITH

SAME TYPE  FUSE AND RATING

ATTENTION: UTILISER UN FUSIBLE DE

RECHANGE DE MEME TYPE ET CALIBRE

T 1,25A L

+3

-3

-6

+10

+25

+20

dB

0

1

2

3
4
5

6

1. Power Switch
2. Volume

Set the volume control to a desired level as 

music is being played through the unit.

A setting of 0 dB on the SUBWOOFER LEVEL 

control is the correct starting point when setting 

up a sound system. From there the sound can 

be adjusted for best sound. The 0 dB mark refers 

to the setting that will give full power when the 

line input is used and the input signal is at a 

level of +4 dBV. This also is the setting to give a 

sensitivity of 2.83 Vrms (1 watt 8-ohms) for 100 

dB spl when set for speaker level input. With 

a typical full range companion speaker this 

will give flat response. In either line or speaker 

operation it will usually be desireable to set the 

control at +3 to +6 to give some bass boost 

at low power levels. At levels approaching 

full power the built-in limiter will automatically 

reduce the gain to prevent over powering the 

subwoofer. Operation with settings significantly 

above +12 may clip the circuitry in the 

subwoofer reducing the dynamics of the music. 

Setting the subwoofer gain above +12 is only 

appropiate at low operating levels.

3. Ground Lift

If a hum, or buzz is detected from the 

subwoofer, try setting the switch to the GND 

LIFT position (OUT position). The switch should 

otherwise be left in the GND (IN position). 

4. Input Level Switch 

 

Speaker

 

Normally, the input to the subwoofer is 

from a full-range speaker cabinet, or amplifier 

output.  (See figure 2.0) 

 

Line

 

In this case, the input to the subwoofer 

is from a line level source such as a mixer. 

5. Input Jacks

The two inputs are balanced 1/4 inch parallel 

jacks and can be connected as shown 

in figures 2 and 3, on the following page. 

Please note that there is no effect to the 

performance of the full-range speaker if it is 

used to supply a music signal to the LS200P. 

6. Power ON LED

Summary of Contents for ELITE LS200P

Page 1: ...LS200P OWNER S MANUAL MANUEL de L UTILISATEUR Yorkville TYPE YS1019 ...

Page 2: ...CTRIQUE N ENLEVEZ PAS LE COUVERT OU LE PANNEAU ARRIERE NE CONTIENT AUCUNE PIECE REPARABLE PAR L UTILISATEUR CONSULTEZ UN TECHNICIEN QUALIFIE POUR L ENTRETIENT INSTRUCTIONS RELATIVES AU RISQUE DE FEU CHOC ÉLECTRIQUE OU BLESSURES AUX PERSONNES Veuillez Lire le Manuel Il contient des informations qui devraient êtres comprises avant l opération de votre appareil Conservez S V P ces instructions pour c...

Page 3: ...l give full power when the line input is used and the input signal is at a level of 4 dBV This also is the setting to give a sensitivity of 2 83 Vrms 1 watt 8 ohms for 100 dB spl when set for speaker level input With a typical full range companion speaker this will give flat response In either line or speaker operation it will usually be desireable to set the control at 3 to 6 to give some bass bo...

Page 4: ...es not have a U ground a ground pin on the AC cord the ground lift switch must be set to gnd The LS200P may be wired before or after the full range speakers The LS200P does not alter the signal to the full range speakers The LS200P will not draw any power from the amplifier driving the full range speakers Please note that an external crossover is not necessary Figure 2 Full Range Cabinet Full Rang...

Page 5: ...b 50 110 Driver Configuration 10 inch LF Driver s 10 inch LF Protection Electronic Limiting excursion thermal clip LF Power Amplifier Watts 200 Power Cable Yes Power Switch Yes Inputs 1 4 inch Jacks 2 line inputs 2 link in out Level Controls Main Volume Selectable line or speaker level input Ground lift switch Corners Black Steel Feet Plastic Glides Bar Handles 2 Side mounted Pole Mount Adapter 1 ...

Page 6: ...cté du subwoofer réglez le commutateur à la position GND LIFT position sortie Le commutateur devrait autrement être laissé à la position GND position poussée 4 Commutateur de Niveau d Entree Haut Parleur Ce contrôle règle le niveau de sortie de l amplificateur figure 2 Ligne Dans ce cas le signal est acheminé au subwoofer à partir d une source de niveau de ligne sortie d une table de mixage 5 Pris...

Page 7: ... la terre sur le cordon d alimentation le commutateur de découplage de mise à la terre doit être réglé à la position GND Le LS200P peut être connecté avant ou après les haut parleurs pleine gamme L LS200P ne modifie pas le signal acheminé aux haut parleurs pleine gamme Le LS200P ne prélevera pas de puissance de l amplificateur qui propulse les haut parleurs pleine gamme Veuillez noter qu un filtre...

Page 8: ...uences Graves 10 pouces Protection Fréquences Graves Limiteur électronique excursion thermique écrêtage Amplificateur de puissance Fréquences Graves Watts 200 Cordon d Alimentation Oui Commutateur de mise en marche Oui Entrées 1 4 Jacks 2 entrées ligne 2 link entrée sortie Contrôles de Niveau Volume général Entrée commutable entre niveau ligne et niveau haut parleur Commutateur de découplage de mi...

Page 9: ...e de faire enregistrer votre nom auprès de Yorkville Sound ou de votre détaillant Si pour une raison quelconque ce produit devient défectueux durant les deux années qui suivent la date d achat initial dix ans pour l ébénisterie retournez le simplement à votre détaillant Yorkville avec la preuve d achat original et il sera réparé gratuitement Ceci inclus tous les produits Yorkville à l exception de...

Page 10: ...4625 Witmer Industrial Estate Niagara Falls New York 14305 USA Voice 716 297 2920 Fax 716 297 3689 WORLD HEADQUARTERS CANADA Yorkville Sound 550 Granite Court Pickering Ontario L1W 3Y8 CANADA Voice 905 837 8481 Fax 905 837 8746 ...

Reviews: