7
18. Zone Output Terminal Strip
This output terminal connects to the speaker lines. Total speaker wattage is up to
nominal power for zones 1-4. When using a zone selector low-impedance speakers
cannot be used, default is constant voltage 70V output.
19. Output Terminal Strip
These 5 terminals allow connecting speakers.
COM
25V
70V
100V
DC 24V 15A
+
-
4
Ω
24Vdc
COM
0
70V
COM
COM
Zone 4 Zone 3 Zone 2 Zone 1
0
70V
0
70V
0
70V
Connecting the speakers to 70V output
COM
25V
70V
100V
DC 24V 15A
+
-
4
Ω
4-ohms
Connecting the speakers to 4-ohm output
COM
25V
70V
100V
DC 24V 15A
+
-
4
Ω
8-ohms
Total Impedance 4-ohms
8-ohms