826081-XIM-C-0214
6
Johnson Controls Unitary Products
Product Nomenclature
Z F 048 N04 A 7 A AA 1 0 1 2 4 A
Z = A/C, Single Pkg., R-410A
Product Category
Airflow
Product Generation
1 = First Generation
C00 = Cooling Only. Suitable for Field
Installed Electric Heat
Heat Type and Nominal Heat Capacity
E05 = 5 KW
E07 = 7 KW
E10 = 10 KW
E15 = 15 KW
E20 = 20 KW
E30 = 30 KW
Gas Heat Options
Electric Heat Options
036 = 3.0 Ton
Nominal Cooling Capacity
048 = 4.0 Ton
060 = 5.0 Ton
076 = 6.3 Ton
Product Identifier
F = 13.0 SEER, A/C
= 11.0 EER, A/C
Voltage
7 = 380/415-3-50
Product Style
A = Style A
A = No Options Installed
Installation Options
B = Option 1
C = Option 2
D = Options 1 & 2
E = Option 3
F = Option 4
G = Options 1 & 3
H = Options 1 & 4
J = Options 1, 2 & 3
K = Options 1, 2, & 4
L = Options 1,3 & 4
M = Options 1, 2, 3, & 4
N = Options 2 & 3
P = Options 2 & 4
Q = Options 2, 3, & 4
R = Options 3 & 4
1 = Disconnect
2 = Non-Pwr'd Conv. Outlet
3 = Smoke Detector S.A.
4 = Smoke Detector R.A.
Options
SS Drain Pan
Configuration Options (not required for all units)
These four digits will not be assigned until a quote is requested, or an order placed.
CPC Controller, DFS, APS
Johnson Controller UNT 1126 (N2 protocol), DFS, APS
Honeywell Controller, DFS, APS
Novar Controller, DFS, APS
Simplicity IntelliComfort Controller
Simplicity IntelliComfort Controller w/ModLinc
2" Pleated filters
BAS Ready Economizer (2-10 V.D.C. Actuator Without a Controller)
Any Combination of Additional Options that Don’t Have an Option Code Pre-assigned
AA = None
Standard Cabinet
AB = Phase Monitor
AC = Coil Guard
AD = Dirty Filter Switch
AE = Phase Monitor & Coil Guard
AF = Phase Monitor & Dirty Filter Switch
AG = Coil Guard & Dirty Filter Switch
AH = Phase Monitor, Coil Guard & Dirty Filter Switch
AS = Bottom Drain Connection
RC = Coil Guard & American Flag
TA = Technicoat Condenser Coil
TJ = Technicoat Evaporator Coil
TS = Technicoat Evaporator and Condenser Coil
Additional Options
Hinged & Toolless Access Cabinet
BA = Hinged & Toolless Filter, Motor and Electrical
Access Panels
BB = Phase Monitor, Hinged & Toolless Filter, Motor
and Electrical Access Panels
BC = Coil Guard, Hinged & Toolless Filter, Motor and
Electrical Access Panels
BD = Dirty Filter Switch, Hinged & Toolless Filter,
Motor and Electrical Access Panels
BE = Phase Monitor & Coil Guard, Hinged & Toolless
Filter, Motor and Electrical Access Panels
BF = Phase Monitor & Dirty Filter Switch, Hinged &
Toolless Filter, Motor and Electrical Access
Panels
BG = Coil Guard & Dirty Filter Switch, Hinged &
Toolless Filter, Motor and Electrical Access
Panels
BH = Phase Monitor, Coil Guard & Dirty Filter Switch,
Hinged & Toolless Filter, Motor and Electrical
Access Panels
York Commercial Comfort System (YCCS) Rtu Controller
1
1. 3 thru 6.3 Ton Units
EA = ElectroFin Condenser Coil
EJ = ElectroFin Evaporator Coil
ES = ElectroFin Cond & Evap Coils
A = Direct Drive
B = Direct Drive/Economizer
D = Direct Drive/Motorized Damper
N = Belt Drive
P = Belt Drive/Economizer
R = Belt Drive/Motorized Damper
N04 = 40 MBH Output Aluminized Steel, 1 Stage (036)
N06 = 60 MBH Output Aluminized Steel, 1 Stage (048)
N08 = 80 MBH Output Aluminized Steel, 1 Stage
(060, 076)
S04 = 40 MBH Output Stainless Steel, 1 Stage (036)
S06 = 60 MBH Output Stainless Steel, 1 Stage (048)
S08 = 80 MBH Output Stainless Steel, 1 Stage
(060, 076)