background image

Outdoor Air Options- All fresh air 

and exhaust hoods ship mounted 

and ready. Aluminum mesh filters 

and barometric relief dampers 

included on all product ordered 

with a motorized damper or 

economizer.  

Outdoor Air Options Continued- 

Millennium packaged products 

equipped with “Tilt-Out” side fresh 

air hoods. Simply tilt the hoods out 

and secure with two screws and 

Done!  

With the combination of both side 

and end return hoods 100% 

economizer operation is possible. 

Many competitors cannot achieve 

100% economizer operation due to 

insufficient fresh air intake points.   

Modulating, Multi-Staged Gas 

Heat Options- Choose from single, 

dual or three stage gas heat (3 

stages 40 ton only). Modulating 

gas heat is available on all 25-40 

ton units that achieves up to an 8:1 

turn-down.   

Hot water, steam and electric heat 

is also available. 

Summary of Contents for ZF 036-072

Page 1: ...ER 7 7 HSPF XN 036 060 36 60 MBH 14 SEER 11 8 12 0 EER 8 0 HSPF Standard Limited Warranties Compressor 5 Years Aluminized Heat Exchanger 10 Years Stainless Steel Heat Exchanger 15 Electric Heat Elemen...

Page 2: ...nser Section Microchannel All Aluminum Condenser standard on ZF ZE models provides enhanced heat transfer more durable lower refrigerant charge required vs traditional copper tube alum fin Fin tube co...

Page 3: ...ote unit data access is available via the Mobile Access Portal device MAP providing wireless or internet connectivity to the equipment Fault Detection and Diagnosis FDD available to monitor refrigeran...

Page 4: ...Control AC Units Model Cooling Capacity MBH SEER IEER Range EER Heating Efficiency ZX04 06 35 59 MBH 13 SEER 11 0 EER 80 SSE ZY04 06 36 58 MBH 15 15 4 SEER 12 0 EER 80 SSE ZX07 14 69 135 MBH 11 5 11...

Page 5: ...nd reliability Blower Section H Dynamically balanced indoor fans for better performance and reliability Easy access for service and maintenance Direct drive and belt drive options available on 3 5 ton...

Page 6: ...eel heat exchanger with optional stainless steel heat exchanger Gas heat exchanger installed at slight angle to facilitate condensate drainage in cooling mode Electric heat available as a field instal...

Page 7: ...or 5 Years Aluminized Heat Exchanger 10 Years Stainless Steel Heat Exchanger 15 Years Electric Heat Element 5 Years Other Parts 1 Year Key Talking Points 18 SEER ZT models are industry leading Multipl...

Page 8: ...and 12 5T HP each have different coil configuration Standard hinged and tool less access panels 3 10 Ton AC HP 12 5 Ton AC 12 5 Ton HP Air Filter Racks Air filters are easily removed by rotating the...

Page 9: ...on number of compressors or heating stages energized For ease of maintenance the entire blower assembly slides outward in the track on the base On VFD units the supply fan VFD is located in the blower...

Page 10: ...ation and maintenance easy Optional remote unit data access is available via the Mobile Access Portal device MAP providing wireless or internet connectivity to the equipment Fault Detection and Diagno...

Page 11: ...ating provides further protection Optional epoxy coating is available for harsh environments Maintenance benefits microchannel coils are more durable than traditional tube fin design and can handle hi...

Page 12: ...r IEER values utilize optional VFDs Standard Limited Warranties Compressor 5 Years Aluminized Heat Exchanger 10 Years Stainless Steel Heat Exchanger 15 Years Electric Heat Element 5 Years Other Parts...

Page 13: ...ZR ZJ XP 20 ton Magnum Cabinet Air Filter Racks Air filters are easily removed through access panel Filter racks accommodate either 2 or 4 filters Blower Assembly Belt drive motors with standard low s...

Page 14: ...dampers are rated at 3 cfm ft2 Control Section Product features the Simplicity Smart Equipment Control SSE a digital control systems that makes system setup optimization and maintenance easy Optional...

Page 15: ...Condenser Section All condenser coils on 15 25T units are copper tube and aluminum fin Number of condenser fans per unit are as follows ZF All 2 fans ZR ZJ All 4 fan XP 15 Ton 2 fan 20 Ton 4 fans...

Page 16: ...ating options Hinged tool less access panels Electrical blower filters economizer power exhaust sections Double walled cabinet Merv 7 and 14 air filters and painted or stainless steel condensate pan o...

Page 17: ...ariable air volume options available The onboard Simplicity SE control allows multiple airflow configurations including factory and customer installed variable frequency drive options Simplicity Smart...

Page 18: ...rovide flexibility and correct motor sizing to assure proper airflow and maximum energy savings Indoor Air Quality IAQ options Offered from simple 2 throw away air filters to 6 95 efficiency MERV 14 f...

Page 19: ...y tilt the hoods out and secure with two screws and Done With the combination of both side and end return hoods 100 economizer operation is possible Many competitors cannot achieve 100 economizer oper...

Page 20: ...dle of the packaged units crane lifts are quick and easily rigged and prevent any possible unit damage as long as proper rigging is done Some competitors punch holes in the base rails for rigging thus...

Reviews: