background image

INSTALLATION

&

OWNER’S MANUAL

MINISPLIT FLOOR/CEILING

AIR CONDITIONER

MODELS :

YOCA-YOHA

 12-60

REQUIRED

T

OOLS

1.

Screw Driver

  9.

Manifold Guage

2.

Hexagonal

W

rench

10.

Gas Leak Detector

3.

Torque

W

rench

11

.

V

acuum Pump

4.

Spanner

12.

Pipe Clamp

5.

Reamer

13.

Pipe Cutter

6.

Hole Core Drill

14.

Flare

Tool Set

7.

Tape Measure

15.

Electrical Circuit T

ester

8.

Thermometer

EXTENDED

PARTS

1.

Refrigerant Pipe : See

Technical Specifi

cation

2.

Pipe Insulation Material (Polyethylene foam 9 mm thick)

3.

V

inyl

Tape

4.

Putty

Please read this installation manual carefully before starting installation

of the unit.

This air conditioning system contains refrigerant under pressure, rotating

parts and electrical connection which may be dangerous and can cause

injury

. Installation and maintenance of this air conditioning system should

only be carried out by trained and qualifi

ed personnel.

After unpacking, please check the unit carefully for possible damage.

Before undertaking any work on the unit, make sure that the power supply

has been disconnected.

CAUTIONS FOR INST

ALLA

TION

Do not store or unpack the unit

in a wet area or expose to rain

or water

.

It may cause the unit to short circuit and may

result electric shocks or fi

re.

Do not install in a place where

flammable gas may leak.

It may cause fi

re.

Do not conduct installation in wet

area or in the rain.

It is a high risk to cause the electrical shocks.

This system is designed for

domestic or residential use only

.

If used in certain environments, such as a

manufacturing workplace, the equipment may

not function effi

ciently

.

PART LIST

INDOOR UNIT

YOCA-YOHA

INST

ALLA

TION

ACCESSORIES

ENGLISH

EN

Ceiling & Floor T

ype

PREP

ARA

TION BEFORE INST

ALLA

TION

Before doing any work, check the interior power supply cord and the main

breaker capacity are suffi

cient and the installation area is suffi

cient and

complies with the requirements.

Check that the power supply available agrees with nameplate voltage.

Electrical work, wiring and cables must be performed in compliance with

national and local wiring codes and standard.

Do not use the extension cables. In the case extended cables are needed,

use the terminal block.

SELECTION OF THE LOCA

TION

INDOOR UNIT

OUTDOOR UNIT

INST

ALLA

TION

INST

ALLA

TION SITE

To

 install the air conditioner in the following types of environments,

consult the shop.

Places with an oily ambient or where steam or soot occurs.

Salty or corrosive environments such as coastal areas.

Places where sulfi

de gas occurs such as hot springs.

The drain from the outdoor unit must be discharged to a place of good drainage.

CONSIDER NUISANCE T

O

YOUR NEIGHBOURS 

FROM NOISES

For installation choose a place as described below

.

A

 place solid enough to bear the weight of the unit and which does not 

amplify the operation noise or vibration.

A

 place from where the air discharged from 

the outdoor unit or the operation noise 

will not annoy your neighbours.

ELECTRICAL

 WORK

For power supply

, be sure to use a separate power circuit dedicated to the air

conditioner

.

SYSTEM RELOCA

TION

Relocating the air conditioner requires specialized knowledge and skills.

Please consult the shop where you bought the air conditioner if relocation is

necessary for moving or remodelling.

SAFETY

 PRECAUTIONS

Select a place which provides the space around the units 

as shown in

the diagram below

.

To

 prevent

interference,

place at least

1m away

.

Inverter-type

fluorescent

lamp.

TV

A

 place with

good

ventilation.

Air

Outlet

Air Inlet

Radio

035M00173-003

Dimension

(mm)

YOCA-YOHA

12

18

24

36

48

60

A

2300

2300

2300

2300

2300

2300

B

2300

2300

2300

2300

2300

2300

C

555555

D

120

120

120

120

120

120

Dimension

(mm)

YOCA-YOHA

12

18

24

36

48

60

A

300

300

300

300

300

300

B

2

000

2

000

2

000

2

000

2

000

2

000

C

600

600

600

600

600

600

D

300

300

300

300

300

300

Description

Qty

USE

Hook

2

For wall mounting installation

Hanging arm

2

For ceiling 

installation

Tapping Screw (ST2.9x10-C-H)

2

Remote Controller

1

Frame

Alkalina dry batteries (AM4)

1

Install & Owner

’s manual and User

’s

guide

Installation

&

Owner's ma

nual

User' s Guid

e

2

NAMES

AND FUNCTIONS

NOTICE!

The

chart

based

on

one

model

of

our

product

is

for

reference

only

,which

may

be

diff

erent from the unit you purchased.

a

indoor unit

b

outdoor unit

c

remote controller

d

air-in

e

air

flow louver (at air outlet)

f

connecting pipe

g

drain hose

h

air inlet (with air fi

lter in it)

i

installation part

j

DEF

./

FAN

indicator

(For

cooling

and

heating

type,

it’

s

DEF

.,

for

cooling

only

type, it’

s

FAN)

k

infrared signal receiver

l

operation lamp

m

timer indicator

n

alarm indicator

o

temporary button

p

air-out

f

c

g

n

m

o

l

k

J

i

a

e

d

h

p

b

d

p

OPERATION

TIMER

DEF./FAN

ALARM

MANUAL

W

A

LL

 MOUNTING INST

ALLA

TION

D.

Connecting point 

of refrigerant pipe

(D. gas side)

Drain

 point

E.

Connecting point 

of refrigerant pipe

(E. Liquid side)

Hook

Chart 5

1.

Fix the hook with tapping screw onto the wall. 

(Refer to Chart 6)

2.

Hang the indoor unit on the hook.

<6m

m

Hook

Chart

6

Tapping screw

W

asher

Display Panel

J422_EN.indd   1

10/30/07   11:00:45 AM

Summary of Contents for YOCA-YOHA 12-60

Page 1: ...sive environments such as coastal areas Places where sulfide gas occurs such as hot springs The drain from the outdoor unit must be discharged to a place of good drainage CONSIDER NUISANCE TO YOUR NEIGHBOURS FROM NOISES For installation choose a place as described below A place solid enough to bear the weight of the unit and which does not amplify the operation noise or vibration A place from wher...

Page 2: ...ly over the roof beam then install the hanging screw bolts Refer to Chart 1 Inlaying or embedding the screw bolts Refer to Chart 2 Use embedding screw bolt Refer to Chart 3 Install and use directly the supporting angle steel Refer to chart 4 Timber over the beam Roof beam Ceiling Hanging screw bolts Chart 1 Chart 2 Blade shape insertion Slide insertion Steel bar Embedding screw bolt Pipe hanging a...

Page 3: ...GRRU HDWLQJ QGRRU RROLQJ 2XWGRRU HDWLQJ 2XWGRRU RROLQJ 2XWGRRU HDWLQJ 2XWGRRU RROLQJ 2XWGRRU HDWLQJ 2XWGRRU 3K RROLQJ 2XWGRRU 3K RROLQJ 2XWGRRU 3K HDWLQJ 2XWGRRU 3K HDWLQJ 2XWGRRU RROLQJ 2XWGRRU HDWLQJ 2XWGRRU RROLQJ 2XWGRRU HDWLQJ 2XWGRRU HDWLQJ QGRRU RROLQJ QGRRU HDWLQJ QGRRU RROLQJ QGRRU HDWLQJ QGRRU RROLQJ QGRRU B 1 LQGG 0 ...

Page 4: ...mum Piping Lengths See Technical Specification Note Where the difference in elevation between the indoor unit and the outdoor unit is greater than 5 meters install an oil trap every 5 meters The suction line must have a 2 gradient up to the compressor on horizontal sections Where piping lengths are unusually long and include a large number of oil traps it may be necessary to adjust to compressor c...

Page 5: ...WKH WLPH HODSVHG LV OHVV WKDQ PLQXWHV WKHQ WKH FRPSUHVVRU VWDUW XS ZLOO EH GHOD HG XQWLO PLQXWHV KDV SDVVHG LOWHU DUH DQG LOWHU ODUP 5HSODFH LU 3XULI LQJ ÀOWHU LI ÀWWHG 7KH ÀOWHUV VKRXOG EH FOHDQHG UHJXODUO L H RQFH D PRQWK RU PRUH IUHTXHQWO GHSHQGLQJ RQ FRQGLWLRQV 7KH FRQWURO LV HTXLSSHG ZLWK D ÀOWHU DODUP IWHU D FHUWDLQ QXPEHUV RI KRXUV RI RSHUDWLRQ ÁDVKLQJ OLJKWV ZLOO LQGLFDWH WKDW LW LV WLPH W...

Page 6: ...R OXPLQXP DOOR LDPHWHU PP 0RWRU 4XDQWLW 6SHHG USP 0D 6WDUWLQJ XUUHQW 5XQQLQJ XUUHQW QSXW 3RZHU 2XWSXW 3RZHU DSDFLWRU P 3URWHFWRU QQHU WKHUPDO 2YHUORDG 3URWHFWLRQ QVXODWLRQ ODVV 3 5DWLQJ 3 3 3 3 3 3 RPSUHVVRU 4XDQWLW 7 SH 6FUROO 6FUROO 6FUROO 6FUROO 6FUROO 6FUROO 2LO KDUJH FF DSDFLWRU P 0D 6WDUWLQJ XUUHQW 5XQQLQJ XUUHQW QSXW 3RZHU N 3URWHFWRU QQHU WKHUPDO 2YHUORDG 3URWHFWLRQ 9LEUDWLRQ VRODWRU 5XEEH...

Reviews: