Have the unit professionally installed.

Improper installation by an unqualified person may result

in water leak, electric shock, or fire.

Be sure to carefully follow each step in this handbook when

installing the unit.

Improper installation may result in water leak, electric shock,

smoke or fire.

Have all electrical work performed by a licensed electrician

according to the local regulations and the instructions given

in this manual. Secure a circuit designated exclusively to

the unit.

Improper installation or a lack of circuit capacity may cause

the unit to malfunction or present a risk of electric shock,

smoke,and fire.

Place the unit on a stable, level surface that withstands the

weight of the unit to prevent the unit from tipping over or

falling causing injury as a result.

Only use specified cables for wiring. Securely connect each

cable, and make sure that the cables are not straining the

terminals.

Cables not connected securely and properly may generate

heat and cause fire.

Take necessary safety measures against typhoons and

earthquakes to prevent the unit from falling over.

Do not make any changes or modifications to the unit. In

case of problems, consult the dealer.

If repairs are not made properly, the unit may leak water

and present a risk of electric shock, or it may produce smoke

or cause fire.

Securely attach the terminal cover(panel) on the unit.

If installed improperly, dust and/or water may enter the unit

and present a risk of electric shock, smoke or fire.

Only use refrigerant R410A as indicated on the unit when

installing or relocating the unit.

The use of any other refrigerant or an introduction of air into

the unit circuit may cause the unit to run an abnormal cycle

and abnormal cycle and cause the unit to burst.

In the event of a refrigerant gas leak, provide adequate

ventilation to the room.

If leaked refrigerant gas is exposed to a heat source, noxious

gases may form.

Do not touch the fins on the heat exchanger with bare hands,

for they are sharp and dangerous.

Do not try to defeat the safety features of the devices, and

do not change the settings.

Defeating the safety features on the unit such as the pressure

switch and temperature switch or using parts other than the

dealer or specialist may result in fire or explosion.

When installing the unit in a small room, safeguard against

hypoxia that results from leaked refrigerant reaching the

threshold level.

Consult the dealer for necessary measures to take.
When relocating the air conditioner, consult the dealer or

a specialist.

Improper installation may result in water leak, electric shock,

or fire.
After completing the service work, check for a refrigerant

gas leak.

If leaked gas refrigerant is exposed to a heat source such

as fan heater,stove,and electric grill, noxious gases may

form.
Only use specified parts.

Have the unit professionally installed. Improper installation

may cause water leak, electric shock,smoke, or fire.

With All-Fresh type air 

conditioners

, outdoor air may be

directly blown into the room upon thermo off. Take this into

consideration when installing the unit.

Direct 

exposure

 to outdoor air may present a health hazard,

and it may also cause food items to deteriorate.

WARNING

WARNING

Safety Precautions

3

Summary of Contents for YMUJYH(012-018)BAM-A-X

Page 1: ...Read this manual before installation and operation Make sure that it is well kept for later reference Outdoor Inverter R410a 50 60HZ INSTALLATION MANUAL YMUJYH 012 018 BAM A X ...

Page 2: ... affect the ƽ house x the unit by attaching a vibration proof mat The marks from to in the gure are the parts numbers The distance between the indoor unit and the Àoor should be more than 2m The models adopt HFC free refrigerant R410A more than 10cm more than 15cm more than 10cm more than 20cm more than 20cm more than 25cm more than 60cm A G ƽ ƽ A F C E D G B Arrangement of piping directions Rear ...

Page 3: ...WARNING CAUTION 2 ...

Page 4: ...as indicated on the unit when installing or relocating the unit The use of any other refrigerant or an introduction of air into the unit circuit may cause the unit to run an abnormal cycle and abnormal cycle and cause the unit to burst In the event of a refrigerant gas leak provide adequate ventilation to the room If leaked refrigerant gas is exposed to a heat source noxious gases may form Do not ...

Page 5: ... connections Use liquid refrigerant to charge the system Charge the unit with gas refrigerant will cause the refrigerant in the cylinder to change its composition and will lead to a drop in performance Do not use a charging cylinder The use of charging cylinder will change the composition of the refrigerant and lead to power loss Exercise special care when handling the tools An introduction of for...

Page 6: ...follow the instructions in the manual and make sure that they properly drain water so as to avoid dew condensation If not installed properly they may cause water leaks and damage the furnishings Do not spray water on the air conditioners or immerse the air conditioners in water Water on the unit presents a risk of electric shock Periodically check the platform on which is placed for damage to prev...

Page 7: ...efrigerant charging Vacuum Gauze Checking vacuum degree Tools Materials Use Notes Charging Cylinder Refrigerant Charging Must not be used with R410 type units CAUTION Items to Be Checked 1 Verify the type of refrigerant used by the unit to be serviced Refrigerant Type R410A 2 Check the symptom exhibited by the unit to be serviced Look in this service handbook for symptoms relating to the refrigera...

Page 8: ...ss If a clutch type flare tool is used to machine flares on units that use R410A make the protruding part of the pipe between 1 0 and 1 5mm Copper pipe gauge for adjusting the length of pipe protrusion is useful Size mm Radial Thickness mm Size inch Type Type O pipes Type 1 2H or Hpipes Piping Materials Types of Copper Pipes Reference The table shows the standards in Japan Using this table as a re...

Page 9: ...8 ...

Page 10: ...NO Wind direction Air outlet 12K 18K Cushion rubber 4 Installation dimension Unit mm 9 ...

Page 11: ...engthened the refrigerant should be charged according to E g m But the charge of refrigerant must be conducted by professional air conditioner engineer Before adding additional refrigerant perform air purging from the refrigerant pipes and indoor unit using a vacuum pump then Spanner Forced fastening without careful centering may damage the threads and cause a leakage of gas Pipe Diameter Ǜ Fasten...

Page 12: ...11 ...

Page 13: ... e g 1U18FS1ERA 12 ...

Page 14: ...Indoor unit Model Connecting wiring Power cable 3G2 5mm2 3G1 5mm2 4G0 75mm 2 4G0 75mm 2 To Indoor unit Outdoor unit POWER FOR 12K FOR 18K 12K 18K 12K 18K 3 2 1 N L C 3 2 1 N L C N 1 3 C L 2 L N POWER Outdoor unit 13 ...

Page 15: ... 15 8 12 10 5 13 19 1 18 4 11 6 25 25 25 110 Suction temperature sensor failure When the The wiring of compressor is wrong or the connection is poor 17 16 15 Lack of refrigerant Check if there is leakage in the unit m 14 ...

Page 16: ...www johnsoncontrols com AHUJYHAR 130131 2012 Johnson Controls Inc Johnson Controls se reserva el derecho de cambiar las características del produc to sin previa notificación ...

Reviews: