background image

Subject to change without notice. Published in U.S.A.

553202-YTG-A-1209

Copyright

 ©

 2009 by Johnson Controls, Inc. All rights reserved. 

Supersedes Nothing

Johnson Controls Unitary Products

5005 York Drive

Norman, OK 73069

Summary of Contents for YCJD30 S41S1(H)

Page 1: ...e treated galvanized steel provides a better paint to steel bond which resists corrosion and rust creep Special primer formulas and matted textured finish insure less fading when exposed to sunlight Lower Installed Cost Installation time and costs are reduced by easy power and control wiring connections Available in sweat connect models only The unit contains enough refrigerant for matching indoor...

Page 2: ...950 2950 3600 2050 3200 2950 2950 3600 Coil Face Area Sq Ft 9 6 13 07 14 16 14 16 18 68 9 6 13 07 14 16 14 16 18 68 Rows Deep 1 1 1 1 1 1 1 1 1 1 Fin Inches 23 23 23 23 23 23 23 23 23 23 Liquid Line Set OD Field Installed 3 8 3 8 3 8 3 8 3 8 3 8 3 8 3 8 3 8 3 8 Vapor Line Set OD Field Installed 3 4 3 4 7 8 7 8 7 8 3 4 3 4 7 8 7 8 7 8 Unit Charge Lbs Oz 4 3 14 4 9 4 5 4 9 5 6 3 14 4 9 4 5 4 9 5 6 C...

Page 3: ... Charge for Various Matched Systems Outdoor Unit YCJD30S4 3 4 S3 YCJD36S4 3 4 S3 YCJD42S4 3 4 S3 YCJD48S4 3 4 S3 YCJD60S4 3 4 S3 Required Orifice or TXV 1 2 0 061 4F1 0 065 4G1 0 075 4G1 0 073 4H1 0 087 4J1 Factory Charge lbs oz 3 14 4 9 4 5 4 9 5 6 Indoor Coil3 4 Additional Charge oz AHP30 0 AHP36 2 0 AHP42 0 0 AHP SHP60 0 0 AHX30 0 AHX36 2 0 AHX42 8 2 AHX48 0 AHX60 4 F4FP024 F4FP036 F4FP040 0 F5...

Page 4: ... 21 1255 35 0 24 8 13 00 11 00 AHX36 21 1225 35 2 25 0 13 50 11 50 AHX42 21 1190 35 4 25 2 14 00 11 80 F5FP048 24 1235 35 0 24 8 13 00 11 00 F6FP042 21 1290 35 8 25 8 13 50 11 50 YCJD42S4 3 4 S3 AHP42 21 1485 41 0 29 2 13 00 11 00 AHX42 21 1395 42 0 29 9 14 50 12 00 F5FP048 24 1455 41 0 29 2 13 00 11 00 F6FP042 21 1455 42 0 30 1 14 00 11 75 F6FP048 24 1380 41 5 29 4 13 50 11 70 YCJD48S4 3 4 S3 AHP...

Page 5: ...1200 35 0 24 8 13 00 11 00 1000 1400 21 24 UC48 1200 35 0 24 8 13 00 11 00 YCJD42S4 3 4 S3 1200 1600 17 21 FC MC PC43 1400 42 0 29 2 13 00 11 00 1200 1600 21 24 FC MC PC48 1400 42 0 29 2 13 00 11 00 1200 1600 21 HC42 1400 42 0 29 2 13 00 11 00 1200 1600 21 24 UC48 1400 42 0 29 2 13 00 11 00 YCJD48S4 3 4 S3 1400 1800 21 24 FC MC PC48 1600 48 0 34 4 13 00 11 00 1400 1800 21 24 FC MC PC60 1600 48 0 3...

Page 6: ... MC PC43C 21 1260 35 4 25 4 13 45 11 40 T 9X C20 FC MC PC43C 21 1185 35 0 24 6 13 55 11 40 T 8 L X C16 FC MC PC48C 21 1185 35 6 25 2 14 00 11 50 T 8 L X C20 FC MC PC48C 21 1270 35 8 25 8 14 00 11 50 T 9X C16 FC MC PC48C 21 1280 35 8 25 8 13 70 11 50 T 9X C20 FC MC PC48C 21 1205 35 4 25 0 13 70 11 50 T 9X D20 FC MC PC48D 24 1240 35 4 25 0 13 70 11 50 T 8 L X C16 UC48C 21 1185 34 2 24 8 13 50 11 50 ...

Page 7: ...D 21 1690 57 0 37 8 13 50 11 00 T 9X C16 FC PC60C 21 1575 56 0 37 8 13 30 11 00 T 9X C20 FC PC60C 21 1560 56 0 37 8 13 30 11 00 T 9X D20 FC MC PC60D 24 1630 56 5 37 8 13 30 11 00 T 9X C20 FC MC PC60D 21 1645 56 5 37 8 13 30 11 00 T 8 L X C20 FC MC62D 21 1665 57 0 37 8 13 50 11 00 T 8 L X C16 UC60C 21 1640 56 0 37 2 13 00 11 00 T 8 L X C20 UC60D 21 1735 56 5 38 5 13 00 11 00 T 9X C16 FC PC60C 21 15...

Page 8: ...8 77 77 60 78 78 THERMOSTAT SEAL OPENING S WITH PERMAGUM OR EQUIVALENT TO INDOOR COIL TO FURNACE OR AIR HANDLER TERMINAL BLOCK NEC CLASS 2 WIRING NEC CLASS 1 WIRING ALL OUTDOOR WIRING MUST BE WEATHERPROOF CONTROL ACCESS PANEL WEATHERPROOF DISCONNECT SWITCH MINIMUM 18 SERVICE ACCESS CLEARANCE ON ONE SIDE 60 OVERHEAD CLEARANCE 6 CLEARANCE AROUND PERIMETER NOTE ALL FIELD WIRING TO BE IN ACCORDANCE WI...

Page 9: ...2 1 2 1 2 2 2 3 2 2 2 2 2 2 2 2 2 3 2 2 2 2 2 2 2 2 2 3 105 T C 20 5 21 8 20 4 23 7 26 3 22 0 23 1 21 3 24 3 26 4 23 6 24 5 22 1 24 8 26 4 S C 21 0 20 7 17 1 17 4 13 2 22 6 22 7 19 1 19 7 14 3 24 3 24 7 21 0 22 0 15 4 KW 2 3 2 3 2 3 2 4 2 4 2 4 2 4 2 3 2 4 2 5 2 4 2 4 2 3 2 4 2 5 115 T C 18 6 19 8 17 9 20 9 23 5 19 9 21 0 18 8 21 4 23 5 21 2 22 2 19 6 21 8 23 6 S C 19 1 18 9 15 9 16 4 12 3 20 5 20...

Page 10: ... 2 7 2 5 2 6 2 6 2 6 2 6 105 T C 27 9 28 8 27 2 29 8 32 5 27 0 27 8 26 6 29 4 32 2 26 0 26 9 25 9 29 0 31 9 S C 28 7 28 9 25 0 25 0 18 4 27 3 27 2 23 2 23 2 17 3 25 8 25 6 21 5 21 4 16 2 KW 2 8 2 8 2 8 2 8 2 9 2 8 2 8 2 8 2 8 2 9 2 7 2 8 2 7 2 8 2 9 115 T C 24 6 26 0 24 2 26 8 30 1 23 9 25 1 23 4 26 3 29 8 23 3 24 1 22 6 25 9 29 5 S C 26 3 26 3 22 8 24 1 17 8 24 9 24 8 21 3 22 2 16 6 23 5 23 3 19 ...

Page 11: ...3 2 3 3 3 4 3 3 3 3 3 3 3 3 3 4 3 3 3 3 3 3 3 4 3 4 105 T C 35 3 34 7 32 8 37 4 38 7 37 5 36 7 34 2 38 6 39 8 39 8 38 8 35 6 39 8 40 9 S C 32 3 32 1 26 5 26 4 19 6 34 5 34 5 28 8 28 4 20 4 36 7 37 0 31 1 30 5 21 2 KW 3 5 3 5 3 5 3 6 3 7 3 5 3 5 3 5 3 6 3 7 3 6 3 6 3 5 3 6 3 7 115 T C 32 4 31 7 29 2 33 4 34 8 34 5 33 6 30 5 34 6 35 7 36 5 35 5 31 8 35 7 36 7 S C 29 7 30 0 25 0 24 9 18 2 31 6 31 9 2...

Page 12: ...45 4 37 1 37 0 26 3 KW 3 5 3 5 3 5 3 6 3 7 3 6 3 6 3 5 3 7 3 8 3 6 3 6 3 6 3 7 3 8 105 T C 39 8 39 4 37 3 42 4 43 6 41 6 41 1 38 4 43 4 44 0 43 5 42 9 39 5 44 4 44 5 S C 37 1 37 0 30 9 30 9 22 9 38 9 39 3 32 9 33 0 23 9 40 8 41 5 34 9 35 1 25 0 KW 3 8 3 8 3 8 3 9 4 0 3 9 3 9 3 8 3 9 4 1 3 9 3 9 3 8 4 0 4 1 115 T C 36 5 35 9 32 7 38 0 39 3 38 1 37 5 33 9 38 9 39 8 39 7 39 1 35 1 39 8 40 2 S C 33 9 ...

Page 13: ... 37 9 32 3 50 7 50 9 41 4 38 8 30 8 49 0 53 6 43 9 42 3 29 4 KW 4 3 4 3 4 3 4 4 4 5 4 3 4 3 4 3 4 4 4 4 4 3 4 3 4 3 4 4 4 4 105 T C 56 4 52 2 48 8 54 0 60 1 54 0 54 3 50 5 55 7 59 7 51 6 56 3 52 2 57 4 59 4 S C 49 7 45 9 37 5 36 5 29 7 47 9 48 3 40 0 38 7 29 4 46 2 50 6 42 5 40 9 29 0 KW 4 9 4 9 4 9 4 9 5 0 4 9 4 9 4 9 5 0 5 0 4 9 4 9 4 9 5 0 5 0 115 T C 53 8 48 8 45 2 50 2 54 8 51 2 50 9 46 8 51 ...

Page 14: ...t to change without notice Published in U S A 553202 YTG A 1209 Copyright 2009 by Johnson Controls Inc All rights reserved Supersedes Nothing Johnson Controls Unitary Products 5005 York Drive Norman OK 73069 ...

Reviews: