840569-YTG-B-1012
6
Johnson Controls Unitary Products
MA Modular Air Handlers use Coil Only Ratings.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings)
UNIT MODEL
COIL
CFM RANGE
(MIN.-MAX.)
COOLING
MODEL
WIDTH
RATED
CFM
NET MBH
SEER
1
EER
TOTAL
SENS.
13 SEER AC COIL ONLY RATINGS
YCJD18S41S1(H)(E)
FC/MC/PC18
14.5,17.5
450-750
600
17.5
12.9
13.00
11.00
UC18
14.5,17.5
450-750
600
17.5
12.9
13.00
11.00
YCJD24S41S1(H)(E)
FC/MC/PC32
14.5
600-1000
800
24.0
16.7
13.00
11.00
FC/MC/PC35
17.5,21.0
600-1000
800
24.0
16.7
13.00
11.00
FC/MC/PC36
14.5,17.5,21.0
600-1000
800
24.0
16.7
13.00
11.00
FC/MC/PC37
14.5
600-1000
800
24.0
16.7
13.00
11.00
FC/MC/PC43
17.5,21.0
600-1000
800
24.0
16.7
13.00
11.00
UC36
14.5,17.5,21.0
600-1000
800
24.0
16.7
13.00
11.00
YCJD30S41S1(H)(E)
FC/MC/PC32
14.5
800-1200
1000
29.0
21.0
13.00
11.00
FC/MC/PC35
17.5,21.0
800-1200
1000
29.0
21.0
13.00
11.00
FC/MC/PC37
14.5
800-1200
1000
29.0
21.0
13.00
11.00
FC/MC/PC43
17.5,21.0
800-1200
1000
29.0
21.0
13.00
11.00
YCJD36S41S1(H)(E)
FC/MC/PC37
14.5
1000-1400
1200
35.0
24.8
13.00
11.00
FC/MC/PC43
17.5,21.0
1000-1400
1200
35.0
24.8
13.00
11.00
FC/MC/PC48
21.0,24.5
1000-1400
1200
35.0
24.8
13.00
11.00
UC48
21.0,24.5
1000-1400
1200
35.0
24.8
13.00
11.00
YCJD42S41S2(H)(E)
FC/MC/PC43
17.5,21.0
1200-1600
1400
41.5
29.8
13.00
11.00
FC/MC/PC48
21.0,24.5
1200-1600
1400
42.0
30.0
13.00
11.00
FC/MC/PC60
21.0,24.5
1200-1600
1400
41.5
29.6
13.00
11.00
FC/MC62
24.5
1200-1600
1400
42.0
30.4
13.00
11.00
FC64
24.5
1200-1600
1400
42.0
30.8
13.25
11.25
UC48
21.0,24.5
1200-1600
1400
42.0
30.0
13.00
11.00
YCJD48S41S1(H)(E)
FC/MC/PC48
21.0,24.5
1400-1800
1600
48.0
34.4
13.00
11.00
FC/MC/PC60
21.0,24.5
1400-1800
1600
48.0
34.4
13.00
11.00
UC48
21.0,24.5
1400-1800
1600
48.0
34.4
13.00
11.00
UC60
21.0,24.5
1400-1800
1600
48.0
34.4
13.00
11.00
YCJD60S41S1(E)
FC/MC/PC60
21.0,24.5
1600-2000
1800
57.0
38.5
13.00
11.00
FC/MC62
24.5
1600-2000
1800
57.0
38.5
13.00
11.00
FC64
24.5
1600-2000
1800
57.0
39.0
13.50
11.25
UC60
21.0,24.5
1600-2000
1800
57.0
38.5
13.00
11.00
1. Requires a S1-2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.