2.3 HOW TO DRAIN
The base pan ma overflow due to high humidity. To drain the excess water, remove the drain cap from the bottom of the unit (if fitted) and attach a drain
hose (not supplied).
1. Take the drain pan which is packed with the unit.
2. Remove the rubber plug from the bottom of the base pan (if fitted).
3. Install the drain pan over the area of the cabinet where you removed the plug, and secure with 2 screws provided.
4. Connect the drain hose to the outlet located at the bottom of the drain pan. You can purchase the drain hose or tubing locally to satisfy our particular
needs (Drain hose is not supplied).
2.4. HOW TO INSTALL
2.4.1 INSTALLATION OF THE HOUSING
Step1
Remove the air conditioner from it's packaging, remove fixing screws and slide the air conditioner out of it's housing (refer to installation steps)
Step2
Prepare the hole in the wall so that the bottom of the housing is well supported, the top has minimum clearance and the air inlet louvers have clearance
as shown below in options a and b. Holes from the outside through to the cavity should be sealed. The housing should slope down towards the rear b
about 5mm to allow water formed during operation to drain.
Step3
Install the housing into the wall and secure. Ensure the foam seals are not damaged. Flash, seal or fill gaps around the inside and outside to provide
satisfactory appearance and protection against the weather, insects and rodents.