251933-YTG-J-1009
Johnson Controls Unitary Products
91
060
(5.0)
208-3-60 15.6 110.0
24.4
2.3
8.2
10.0
None
-
-
-
40.0
50
E05
4.0
1
11.1
53.9
60
E07
5.6
1
15.5
59.4
70
E10
8.0
1
22.2
67.8
70
E15
11.9
2
33.0
81.3
90
E20
15.9
2
44.1
95.2
100
E30
22.2
2
61.6
117.0
125
230-3-60 15.6 110.0
24.4
2.3
8.2
10.0
None
-
-
-
40.0
50
E05
5.3
1
13.3
55.9
60
E07
7.5
1
18.8
62.6
70
E10
10.6
1
26.6
71.9
80
E15
15.9
2
39.9
87.8
90
E20
21.2
2
53.2
103.7
110
E30
29.6
2
74.3
129.0
150
460-3-60
7.7
52.0
12.1
1.3
4.1
5.0
None
-
-
-
20.0
25
E07
6.8
1
8.5
30.2
35
E10
10.1
1
12.7
35.2
40
E15
13.6
2
17.1
40.5
45
E20
19.5
2
24.5
49.3
50
E30
28.8
2
36.1
63.3
70
575-3-60
5.8
38.9
9.1
1.3
3.6
4.0
None
-
-
-
15.9
20
E10
10.6
1
10.6
28.6
30
E15
15.9
1
16.0
35.0
40
E20
21.2
2
21.3
41.4
45
E30
30.4
2
30.5
52.5
60
1. Minimum Circuit Ampacity.
2. Dual Element, Time Delay Type.
3. HACR type per NEC.
XP036-060 (Belt Drive High Static) (Continued)
Size
(Tons)
Volt
Compressors
(each)
OD Fan
Motors
(each)
Supply
Blower
Motor
Pwr
Conv
Outlet
Electric Heat Option
MCA
1
(Amps)
Max Fuse
2
/
Breaker
3
Size
(Amps)
RLA
LRA
MCC
FLA
FLA
FLA
Model
kW
Stages
Amps