521149-UTG-C-0612
2
Johnson Controls Unitary Products
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
LEFT SIDE
RIGHT SIDE
.5”
.5”
RETURN END
B
24.25”
29.5”
28.5”
Electrical
Entry
Gas Pipe
Entry
Thermostat
Wiring
FRONT
14”
1”
1.5”
23”
SUPPLY END
C
24.38”
20”
.5”
B
Gas Pipe
Entry
Thermostat
Wiring
33”
A
.5”
Electrical
Entry
Vent Connection
Outlet
Vent
Connection
Outlet
4” Diameter
Outlet
Vent Connection
Cabinet and Duct Dimensions
Models
Nominal
CFM
Cabinet
Size
Cabinet Dimensions (Inches)
A
B
C
TM(8,L)T060A12MP11
1200
A
14 1/2
13 3/8
10.3
TM(8,L)T080B12MP11
1200
B
17 1/2
16 3/8
11.8
TM(8,L)T080C16MP11
1600
C
21
19 7/8
13.6
TM(8,L)T100C16MP11
1600
C
21
19 7/8
13.6
TM(8,L)T100C20MP11
2000
C
21
19 7/8
13.6
TM(8,L)T120C20MP11
2000
C
21
19 7/8
13.6
Table 1: Ratings & Physical / Electrical Data
Models
High Fire
Input
Low Fire
Input
High Fire
Output
Low Fire
Output
Nominal
Airflow
AFUE
Max.
Over-current
Protect
Max. Outlet
Air Temp
MBH
MBH
MBH
MBH
CFM
%
°F
TM(8,L)T060A12MP11
60
39
47
31
1200
80.0
10
160
TM(8,L)T080B12MP11
80
52
63
42
1200
80.0
10
160
TM(8,L)T080C16MP11
80
52
63
42
1600
80.0
15
160
TM(8,L)T100C16MP11
100
65
80
52
1600
80.0
15
160
TM(8,L)T100C20MP11
100
65
80
52
2000
80.0
20
160
TM(8,L)T120C20MP11
120
78
96
62
2000
80.0
20
160
Models
High Fire
Air Temp. Rise
Low Fire
Air Temp. Rise
Blower
Blower
Size
Total Unit
Amps
Min. wire Size
(awg) @ 75 ft
one way
Operating
weight
°F
°F
HP
Amps
In.
Lbs.
TM(8,L)T060A12MP11
30-60
15-45
1/3
4.8
11 x 8
7.0
14
94
TM(8,L)T080B12MP11
30-60
20-50
1/3
4.8
11 x 8
7.0
14
103
TM(8,L)T080C16MP11
30-60
20-50
1/2
7.0
11 x 10
10.0
14
114
TM(8,L)T100C16MP11
30-60
20-50
1/2
7.0
11 x 10
10.0
14
118
TM(8,L)T100C20MP11
30-60
20-50
1
14.5
11 x 11
17.0
12
122
TM(8,L)T120C20MP11
30-60
20-50
1
14.5
11 x 11
17.0
12
129