background image

400991-YTG-B-0708

Johnson Controls Unitary Products

5

NOTES:

1. Airflow expressed in standard cubic feet per minute (CFM).

2. Return air is through side opposite motor (left side).

3. Motor voltage at 115 V.

4. Airflow through across motor side (right side) may be slightly less than the data shown above.

Blower Performance CFM - Any Position (without filter) - Left Side Return

Models

Speed

Left Side Airflow Data (SCFM)

Ext. Static Pressure (in. H2O)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

TG9S040A08MP11 

High 

1131 

1091 

1053 

1003 965 921 862 800 733 659 

Medium 

High  982 959 935 887 846 795 745 675 628 595 

Medium 

Low  772 736 715 689 661 642 599 568 531 493 

Low 

636 618 585 569 546 522 486 460 455 370 

TG9S060A10MP11 

High 

1431 1375 1304 1244 1178 1109 1040  963  861  805 

Medium 

High 1280 

1226 

1171 1117 

1059 

1004 930 865 781 731 

Medium 

Low 1099 

1050 

1008 970 919 866 814 759 710 626 

Low 

914 876 842 812 770 728 694 661 612 545 

TG9S060B12MP11 

High 

1470 1406 1361 1309 1241 1155 1060  920  775  628 

Medium 

High 1211 

1186 

1139 

1101 

1042 980 896 796 681 545 

Medium 

Low  970 957 927 889 853 796 745 660 568 450 

Low 

793 781 756 724 694 653 585 530 469 382 

TG9S080B12MP11 

High 

1605 1562 1514 1454 1393 1330 1251 1169 1073  940 

Medium 

High  1372 1318 1280 1255 1205 1161 1093 1023  943  849 

Medium 

Low 1087 

1073 

1052 

1003 993 953 897 843 775 709 

Low 

916 896 881 854 831 802 757 708 642 574 

TG9S080C16MP11 

High 

1956 1907 1846 1778 1717 1647 1573 1483 1353 1209 

Medium 

High  1543 1543 1516 1504 1477 1446 1382 1309 1202 1099 

Medium 

Low  1238 1241 1243 1241 1252 1242 1201 1140 1074  967 

Low 

906 902 903 910 888 866 859 829 795 743 

TG9S080C22MP11 

High 

2585 2492 2405 2321 2232 2137 2015 1902 1745 1577 

Medium 

High  2098 2067 2036 1982 1928 1860 1767 1670 1549 1331 

Medium 

Low  1619 1628 1614 1584 1545 1488 1424 1339 1216 1121 

Low 

1338 1347 1327 1301 1262 1199 1138 1078 1019  938 

TG9S100C16MP11 

High 

1828 1829 1789 1768 1727 1671 1601 1505 1390 1272 

Medium 

High  1422 1444 1437 1424 1396 1326 1301 1253 1200 1100 

Medium 

1224 1229 1243 1234 1219 1193 1168 1135 1088  977 

Low 

813 819 818 814 783 762 756 732 690 642 

TG9S100C20MP11 

High 

2391 2286 2165 2079 2004 1934 1839 1692 1560 1366 

Medium 

High  1945 1878 1838 1782 1694 1642 1565 1451 1334 1163 

Medium 

Low  1549 1530 1495 1430 1431 1365 1284 1192 1097 1022 

Low 

1256 1229 1189 1159 1089 1033 1008  950  871  784 

TG9S120D16MP11 

High 

1998 1987 1914 1858 1798 1721 1629 1530 1417 1303 

Medium 

High  1512 1506 1492 1467 1441 1406 1342 1280 1206 1097 

Medium 

Low  1217 1219 1210 1185 1174 1148 1112 1063 1012  937 

Low 

892 870 859 843 814 798 790 745 740 677 

TG9S120D20MP11 

High 

2343 2253 2167 2071 1979 1881 1785 1668 1473 1351 

Medium 

High  1954 1892 1846 1781 1714 1637 1548 1429 1238 1171 

Medium 

Low  1596 1539 1511 1458 1399 1341 1254 1180  942  988 

Low 

1299 

1261 

1229 

1177 1111 1053 993 937 882 782 

TG9S130D20MP11 

High 

2425 2336 2255 2157 2046 1966 1865 1758 1615 1420 

Medium 

High  1979 1959 1899 1825 1773 1686 1619 1516 1376 1225 

Medium 

Low  1582 1567 1540 1488 1443 1406 1336 1252 1146 1033 

Low 

1305 1287 1239 1194 1159 1126 1062 1003  943  831 

Summary of Contents for TG9S

Page 1: ...to install ideal height 33 tall cabinet Blower off delay for cooling SEER improvement Easy access to controls to connect power control wiring Built in high level self diagnostics with fault code displays standard on integrated control module for reliable operation Low unit amp requirement for easy replacement application Single wire twinning or staging feature available All models are convertable ...

Page 2: ...13 TG9S060A10MP11 1000 A 14 1 2 13 3 8 11 3 4 118 TG9S060B12MP11 1200 B 17 1 2 16 3 8 13 1 4 122 TG9S080B12MP11 1200 B 17 1 2 16 3 8 14 3 4 126 TG9S080C16MP11 1600 C 21 19 7 8 16 1 2 136 TG9S080C22MP11 2200 C 21 19 7 8 16 1 2 139 TG9S100C16MP11 1600 C 21 19 7 8 18 1 4 142 TG9S100C20MP11 2000 C 21 19 7 8 18 1 4 145 TG9S120D16MP11 1600 D 24 1 2 23 3 8 21 3 4 153 TG9S120D20MP11 2000 D 24 1 2 23 3 8 2...

Page 3: ...BR0614 For 14 1 2 cabinets S1 1BR0517 or 1BR0617 For 17 1 2 cabinets S1 1BR0521 or 1BR0621 For 21 cabinets S1 1BR0524 or 1BR0624 For 24 1 2 cabinets 1BR05xx series are galvanized steel filter racks 1BR06xx are pre painted steel filter racks to match the appearance of the furnace cabinet COMBUSTIBLE FLOOR BASE KIT For installation of these furnaces in downflow applications directly onto combustible...

Page 4: ...232 1313 1291 1280 1250 1209 1207 1148 1055 937 Low 826 821 853 858 838 817 794 776 760 711 TG9S080C22MP11 High 2529 2435 2338 2256 2162 2041 1920 1794 1654 1501 Medium High 2166 2111 2070 2001 1927 1849 1719 1614 1499 1344 Medium Low 1697 1685 1664 1631 1586 1531 1466 1393 1315 1185 Low 1383 1377 1358 1336 1285 1244 1199 1147 1048 925 TG9S100C16MP11 High 1909 1880 1823 1776 1706 1637 1562 1474 13...

Page 5: ...1209 Medium High 1543 1543 1516 1504 1477 1446 1382 1309 1202 1099 Medium Low 1238 1241 1243 1241 1252 1242 1201 1140 1074 967 Low 906 902 903 910 888 866 859 829 795 743 TG9S080C22MP11 High 2585 2492 2405 2321 2232 2137 2015 1902 1745 1577 Medium High 2098 2067 2036 1982 1928 1860 1767 1670 1549 1331 Medium Low 1619 1628 1614 1584 1545 1488 1424 1339 1216 1121 Low 1338 1347 1327 1301 1262 1199 11...

Page 6: ... change without notice Printed in U S A 400991 YTG B 0708 Copyright 2008 by Johnson Controls Inc All rights reserved Supersedes 400991 YTG A 0608 Johnson Controls Unitary Products 5005 York Drive Norman OK 73069 ...

Reviews: