FILTER PERFORMANCE

The airflow capacity data published in the “Blower Perfor-
mance” table listed above represents blower performance
WITHOUT filters.

All applications of these furnaces require the use of field
installed air filters. All filter media and mounting hardware or
provisions must be field installed external to the furnace cabi-
net. DO NOT attempt to install any filters inside the furnace.

NOTE: 

Single side return above 1800 CFM is approved as

long as the filter velocity does not exceed filter manufac-
turer’s recommendation and a transition is used to allow use
on a 20x25 filter.

NOTES: 

1. Air velocity through throwaway type filters may not exceed 300 

feet per minute (91.4 m/min). All velocities over this require the 
use of high velocity filters.

2. Do not exceed 1800 CFM using a single side return and a 16x25 

filter. For CFM greater than 1800, you may use two side returns or 
one side and the bottom or one return with a transition to allow 
use of a 20x25 filter.

* - 24" clearance in front and 18" on side recommended for service access.
All furnaces approved for alcove and attic installation.

ACCESSORIES

PROPANE (LP) CONVERSION KIT - 

S1-1NP0347 - All Models except 130K Model
S1-1NP0501 - 130K Model

This accessory conversion kit may be used to convert natural
gas (N) units for propane (LP) operation.

CONCENTRIC VENT TERMINATION -

 

S1-1CT0302 (2")

S1-1CT0303 (3")

For use through rooftop, sidewall. Allows combustion air to
enter and exhaust to exit through single common hole. Elimi-
nates unslightly elbows for a cleaner installation.

SIDEWALL VENT TERMINATION KIT - 

S1-1HT0901 (3")
S1-1HT0902 (2")
For use on sidewall, two-pipe installations only. Provide a
more attractive termination for locations where the terminal is
visable on the side of the home.

CONDENSATE NEUTRALIZER KIT - 1NK0301

Neutralizer cartridge has a 1/2" plastic tube fittings for instal-
lation in the drain line. Calcium carbonate refill media is also
available from the Source 1 Parts (p/n 026-30228-000).

SIDE RETURN FILTER RACKS - 

S1-1SR0200 - All Models
S1-1SR0402 - All Models
S1-1SF0101 - All Models (Upflow Only)

BOTTOM RETURN FILTER RACKS - 

S1-1BR0514 or 1BR0614 - For 14-1/2” cabinets
S1-1BR0517 or 1BR0617 - For 17-1/2” cabinets
S1-1BR0521 or 1BR0621 - For 21” cabinets
S1-1BR0524 or 1BR0624 - For 24-1/2” cabinets

1BR05xx series are galvanized steel filter racks. 1BR06xx
are pre-painted steel filter racks to match the appearance of
the furnace cabinet.

COMBUSTIBLE FLOOR BASE KIT - 

For installation of these furnaces in downflow applications
directly onto combustible flooring material, These kits are
required to prevent potential overheating situations.tible floor
base kit provides access for combustible airflow.
S1-1CB0514 - For 14-1/2” cabinets
S1-1CB0517 - For 17-1/2” cabinets
S1-1CB0521 - For 21” cabinets

S1-1CB0524 - For 24-1/2” cabinets

EAC TRANSITION KITS - 

For installation of EAC accessories with these furnaces to
provide easy transition of return airflow through the EAC to
get the proper sealing and reduced airflow leakage.

S1-1TK1001 - For all models using side return
S1-1TK1014 - For 14-1/2” cabinets using bottom return
S1-1TK1017 - For 17-1/2” cabinets using bottom return
S1-1TK1021 - For 21” cabinets using bottom return
S1-1TK1024 - For 24-1/2” cabinets using bottom return

HIGH ALTITUDE PRESSURE SWITCHES - 

For installation where the altitude is less than 5,000 feet it is
not required that the pressure switch be changed. For alti-
tudes above 5,000 feet, see kits below.
S1-1PS3306 - 040, 080

S1-1PS3307 - 060

S1-1PS3302 - 100, 120, 130

ROOM THERMOSTATS 

- A wide selection of compatible

thermosets are available to provide optimum performance
and features for any installation.

1H/1C, manual change-over electronic non-programmable 
thermostat.

1H/1C, auto/manual changeover, electronic programmable,
deluxe 7-day, thermostat.

1H/1C, auto/manual changeover, electronic programmable.

* For the most current accessory information, refer to the
price book or consult factory.

Recommended Filter Sizes (High velocity 600 FPM)

CFM

Cabinet

Size

Side

(in)

Bottom

(in)

800

A

16 x 25

14 x 25

1000

A

16 x 25

14 x 25

1200

A

16 x 25

14 x 25

1200

B

16 x 25

16 x 25

1600

B

16 x 25

16 x 25

1600

C

16 x 25

20 x 25

2000

C

(2) 16 x 25

20 x 25

2200

C

(2) 16 x 25

20 x 25

2000

D

(2) 16 x 25

22 x 25

Unit Clearances to Combustibles

Application

Upflow

Downflow

Horizontal

Top

1" 0" 0" 

Vent

0" 0" 0" 

Rear

0" 0" 0" 

Side

0" 0" 1" 

Front*

0" 0" 0" 

Floor

Combustible

Combustible

1

1. For combustible floors only when used with special sub-base.

Combustible

Closet

Yes

Yes

Yes

Line Contact

No

No

Yes

Summary of Contents for TG9S

Page 1: ...to install ideal height 33 tall cabinet Blower off delay for cooling SEER improvement Easy access to controls to connect power control wiring Built in high level self diagnostics with fault code displays standard on integrated control module for reliable operation Low unit amp requirement for easy replacement application Single wire twinning or staging feature available All models are convertable ...

Page 2: ...13 TG9S060A10MP11 1000 A 14 1 2 13 3 8 11 3 4 118 TG9S060B12MP11 1200 B 17 1 2 16 3 8 13 1 4 122 TG9S080B12MP11 1200 B 17 1 2 16 3 8 14 3 4 126 TG9S080C16MP11 1600 C 21 19 7 8 16 1 2 136 TG9S080C22MP11 2200 C 21 19 7 8 16 1 2 139 TG9S100C16MP11 1600 C 21 19 7 8 18 1 4 142 TG9S100C20MP11 2000 C 21 19 7 8 18 1 4 145 TG9S120D16MP11 1600 D 24 1 2 23 3 8 21 3 4 153 TG9S120D20MP11 2000 D 24 1 2 23 3 8 2...

Page 3: ...BR0614 For 14 1 2 cabinets S1 1BR0517 or 1BR0617 For 17 1 2 cabinets S1 1BR0521 or 1BR0621 For 21 cabinets S1 1BR0524 or 1BR0624 For 24 1 2 cabinets 1BR05xx series are galvanized steel filter racks 1BR06xx are pre painted steel filter racks to match the appearance of the furnace cabinet COMBUSTIBLE FLOOR BASE KIT For installation of these furnaces in downflow applications directly onto combustible...

Page 4: ...232 1313 1291 1280 1250 1209 1207 1148 1055 937 Low 826 821 853 858 838 817 794 776 760 711 TG9S080C22MP11 High 2529 2435 2338 2256 2162 2041 1920 1794 1654 1501 Medium High 2166 2111 2070 2001 1927 1849 1719 1614 1499 1344 Medium Low 1697 1685 1664 1631 1586 1531 1466 1393 1315 1185 Low 1383 1377 1358 1336 1285 1244 1199 1147 1048 925 TG9S100C16MP11 High 1909 1880 1823 1776 1706 1637 1562 1474 13...

Page 5: ...1209 Medium High 1543 1543 1516 1504 1477 1446 1382 1309 1202 1099 Medium Low 1238 1241 1243 1241 1252 1242 1201 1140 1074 967 Low 906 902 903 910 888 866 859 829 795 743 TG9S080C22MP11 High 2585 2492 2405 2321 2232 2137 2015 1902 1745 1577 Medium High 2098 2067 2036 1982 1928 1860 1767 1670 1549 1331 Medium Low 1619 1628 1614 1584 1545 1488 1424 1339 1216 1121 Low 1338 1347 1327 1301 1262 1199 11...

Page 6: ... change without notice Printed in U S A 400991 YTG B 0708 Copyright 2008 by Johnson Controls Inc All rights reserved Supersedes 400991 YTG A 0608 Johnson Controls Unitary Products 5005 York Drive Norman OK 73069 ...

Reviews: