Multipliers for determining the performance with other indoor sections.
NOTE:
For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
TCHD60S41S3
INDOOR COIL MODEL NO.
FC/MC62
CONDENSING
ENTERING AIR
TEMPERATURE
IDCFM
1750
2000
2250
ID
DB
(°F)
80 80
75
80
80
80 80 75
80
80 80 80
75 80 80
ID
WB
(°F)
57 62 62 67 72 57 62 62 67 72 57 62 62 67 72
65
T.C.
54.0 58.2 58.3 62.9 68.5 55.4 59.4 59.3 64.2 69.8 56.9 60.6 60.3 65.4 71.0
S.C.
54.6 49.2 41.5 41.2 31.7 56.0 51.9 43.5 43.0 32.8 57.5 54.5 45.5 44.8 34.0
KW
3.32 3.35 3.32 3.40 3.48 3.34 3.37 3.34 3.43 3.50 3.37 3.39 3.36 3.45 3.52
75
T.C.
51.8 55.7 55.7 60.6 66.1 53.3 56.9 56.7 61.8 67.3 54.8 58.0 57.8 63.0 68.5
S.C.
52.4 47.8 40.2 39.9 30.8 53.9 50.4 42.2 41.8 31.9 55.4 53.1 44.2 43.7 33.1
KW
3.96 3.98 3.98 4.00 4.05 3.97 3.99 3.98 4.01 4.06 3.98 3.99 3.99 4.03 4.08
85
T.C.
49.7 53.3 53.2 58.3 63.8 51.2 54.3 54.2 59.4 64.9 52.8 55.4 55.2 60.5 66.0
S.C.
50.2 46.4 38.9 38.6 29.8 51.8 49.0 40.9 40.6 31.0 53.4 51.7 42.9 42.5 32.1
KW
4.61 4.61 4.63 4.59 4.61 4.59 4.60 4.62 4.60 4.62 4.58 4.60 4.61 4.60 4.63
95
T.C.
47.6 50.8 50.6 55.9 61.4 49.2 51.8 51.6 57.0 62.4 50.7 52.8 52.6 58.1 63.4
S.C.
48.1 45.0 37.6 37.4 28.9 49.7 47.6 39.6 39.3 30.1 51.3 50.2 41.5 41.3 31.2
KW
5.25 5.23 5.29 5.19 5.18 5.22 5.22 5.26 5.18 5.18 5.18 5.20 5.24 5.17 5.19
105
T.C.
44.8 47.6 47.4 52.8 58.3 46.3 48.6 48.3 53.8 59.3 47.8 49.7 49.2 54.9 60.3
S.C.
45.2 43.1 36.1 36.0 27.8 46.8 45.7 38.0 38.0 29.0 48.3 48.2 39.9 39.9 30.1
KW
6.46 6.36 6.48 6.18 6.04 6.35 6.31 6.42 6.15 6.01 6.25 6.25 6.36 6.11 5.98
115
T.C.
42.0 44.4 44.3 49.8 55.2 43.5 45.6 45.2 50.8 56.3 45.0 46.7 46.0 51.7 57.4
S.C.
42.4 41.3 34.6 34.7 26.8 43.9 43.8 36.5 36.6 27.9 45.4 46.3 38.4 38.6 29.1
KW
7.64 7.46 7.63 7.14 6.88 7.46 7.36 7.54 7.08 6.81 7.28 7.27 7.45 7.03 6.75
125
T.C.
39.3 41.3 41.2 46.8 52.1 40.7 42.5 42.0 47.7 53.2 42.1 43.7 42.8 48.6 54.4
S.C.
39.6 39.5 33.2 33.4 25.7 41.1 41.9 35.0 35.3 26.9 42.5 44.3 36.9 37.2 28.1
KW
8.81 8.56 8.78 8.10 7.72 8.56 8.42 8.66 8.02 7.62 8.31 8.29 8.54 7.94 7.52
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handlers
Coils
T.C.
S.C.
KW
AHX60
–
1.01
1.02
1.01
AV/SV*60 –
0.98
0.96
0.98
F6FP060
–
0.99
0.98
0.99
F*FV060
–
0.96 0.96 0.96
MV20D
FC/MC62D
1.01 1.00 0.98
Furnaces
Coils
T.C.
S.C.
KW
T*(8,L)X*C20
FC/MC62D
0.99
0.97
0.97
Y*9C*C20
FC/MC62D
0.99 0.96 0.98
Y*9C*D20
FC/MC62D
0.99 0.96 0.97
(Y*(8,L)C/T*8V)*C16
HD60
1.00 0.99 0.99
(Y*(8,L)C/T*8V)*C20
HD60
0.98 0.96 0.95
Y*9C*C16
HD60
0.98 0.95 0.96
Y*9C*C20
HD60
0.98 0.95 0.97
Y*9C*D20
HD60
0.98 0.95 0.97